From owner-freebsd-questions Tue Jun 19 2:12:33 2001 Delivered-To: freebsd-questions@freebsd.org Received: from isy.liu.se (isy.liu.se [130.236.48.10]) by hub.freebsd.org (Postfix) with ESMTP id 6CE4937B403 for ; Tue, 19 Jun 2001 02:12:29 -0700 (PDT) (envelope-from mj@isy.liu.se) Received: from lagrange.isy.liu.se (lagrange.isy.liu.se [130.236.49.127]) by isy.liu.se (8.11.4/8.11.4) with ESMTP id f5J9CQT01190; Tue, 19 Jun 2001 11:12:26 +0200 (MET DST) Message-ID: X-Mailer: XFMail 1.4.0 on FreeBSD X-Priority: 3 (Normal) Content-Type: text/plain; charset=iso-8859-1 Content-Transfer-Encoding: 8bit MIME-Version: 1.0 In-Reply-To: <001301c0f89a$d2b1e5e0$0a00a8c0@gdmckee.local> Date: Tue, 19 Jun 2001 11:12:45 +0200 (CEST) From: Micke Josefsson To: G D McKee Subject: Re: UPS Monitor question Cc: FreeBSD Questions Cc: FreeBSD Questions , Mario Doria Sender: owner-freebsd-questions@FreeBSD.ORG Precedence: bulk List-ID: List-Archive: (Web Archive) List-Help: (List Instructions) List-Subscribe: List-Unsubscribe: X-Loop: FreeBSD.ORG I use upsmon from the ports. It comes with upsstat, a program that queries the UPS itself and finds out battery voltages etc. UPSMON Status Reporting Facility --- upsmond version 2.1.3 --- APC UPS 700 Status Info -------------------------------------------------------- Model: SMART-UPS 700 CopyRight: (C) APCC Manufacture date: 12/18/99 Serial #: NS9951331687 Firmware version: 50.11.I Local ID: UPS_IDEN Last battery replace date: 12/18/99 Nominal line voltage: 230 V Nominal battery voltage: 24 V Available: YES Standby: NO Line Power: OK Battery: OK Line Voltage: 231.40 Load: 23.40 % Battery Voltage: 27.60 Battery Level: 100.00 % -------------------------------------------------------- /M On 19-Jun-01 G D McKee wrote: > Hi > > I have a Smart UPS 1000 and the last time the battery lights started > flashing the batteries were on there way out!!! New batteries and some > calibration sorted the problem for me. > > Gordon > > ----- Original Message ----- > From: "Mario Doria" > To: "FreeBSD Questions" > Sent: Sunday, June 17, 2001 3:55 AM > Subject: UPS Monitor question > > >> Hi, >> >> I was using upsd from the ports collection to monitor my ups (APC SmartUPS >> 2400), but sometimes the battery status in the UPS starts blinking, and > the >> sensitivity register gets changed to low. I'm looking for a better >> alternative, any suggestions? >> >> >> Thanks, >> >> >> Mario Doria >> >> >> To Unsubscribe: send mail to majordomo@FreeBSD.org >> with "unsubscribe freebsd-questions" in the body of the message >> > > > To Unsubscribe: send mail to majordomo@FreeBSD.org > with "unsubscribe freebsd-questions" in the body of the message ---------------------------------- Michael Josefsson, MSEE mj@isy.liu.se This message was sent by XFMail running on FreeBSD 4.3-STABLE ---------------------------------- To Unsubscribe: send mail to majordomo@FreeBSD.org with "unsubscribe freebsd-questions" in the body of the message