Date:      Thu, 30 Jan 1997 23:42:32 +0000
From:      Brian Somers <brian@awfulhak.demon.co.uk>
To:        Terry Lambert <terry@lambert.org>
Cc:        dk+@ua.net, shocking@mailbox.uq.edu.au, freebsd-hackers@FreeBSD.ORG
Subject:   Re: Setting MTU from userland ppp 
Message-ID:  <199701302342.XAA20718@awfulhak.demon.co.uk>
In-Reply-To: Your message of "Thu, 30 Jan 1997 09:55:15 MST." <199701301655.JAA22139@phaeton.artisoft.com> 

next in thread | previous in thread | raw e-mail | index | archive | help
> > set mtu 576
> > 
> > in /etc/ppp/ppp.conf
> > 
> > works for me.
> > 
> > This would specify your _tranimission_ size.  To change it on the other
> > side, change the other end's setup.
> > 
> > Don't use 256 as your MTU.  (violates the RFC)
> 
> Any chance of having the software *enforce* the RFC, then?

I'll have a look at the RFC.  It currently checks that 100 <= M[TR]U <= 2000.

-- 
Brian <brian@awfulhak.demon.co.uk>, <brian@freebsd.org>
      <http://www.awfulhak.demon.co.uk/>;
Don't _EVER_ lose your sense of humour....