Skip site navigation (1)Skip section navigation (2)
Date:      Wed, 1 Mar 2000 09:23:28 -0800 (PST)
From:      "Dan B. " <danielb@pacex.net>
To:        John Straiton <ne@clickcom.com>
Cc:        Alexey Koptsevich <ak@astro.ioffe.rssi.ru>, freebsd-questions@FreeBSD.ORG
Subject:   Re: SmartUPS 1400
Message-ID:  <Pine.BSF.4.10.10003010919190.64359-100000@almazs.pacex.net>
In-Reply-To: <018101bf82c9$f7eee850$1f16c6d1@clickcom.com>

next in thread | previous in thread | raw e-mail | index | archive | help
On Tue, 29 Feb 2000, John Straiton wrote:

> > Would be grateful for hint or link: how to halt the system and then
> > power-down the box (AT formfactor) after predetermined time using UPS
> > software, e.g., upsd? I have APC BackUPS Pro.
> 
> edit the /usr/local/etc/upsd.conf file using your favorite editor and about
> a page down you'll see things like
> --
> on "line-fail" after 60 {
> --
> That 60 is an indicator of the time before said action is taken. In this
> case, after 60 seconds of a condition of having no AC power, the system will
> execute a shutdown. Right above this, you will see entries for the warning
> that comes prior. You'll want to adjust it accordingly I can assume.
> 
> John
This is OK, but suppose you have a server hooked-up to a 1400VA UPS (which
will keep going for approx 1hr 30min after an outage) do you realy want to
shutdown in 60 secs? 20 min? why not shutdown when there is only enough
battery power left in the UPS for say 5minutes?

Dan 