Skip site navigation (1)Skip section navigation (2)
Date:      Sat, 27 Apr 1996 23:39:36 -0400 (EDT)
From:      Robert Nicholson <robert@elastica.com>
To:        flexfax@celestial.com
Cc:        questions@freebsd.org
Subject:   Anybody using a Zyxel Elite 2864? (Can not deduce modem type)
Message-ID:  <199604280339.XAA00449@justine.elastica.com>

next in thread | raw e-mail | index | archive | help
My elite is using the latest ROM revision... (dated March 96 I think).

My log is showing the following when I attempt to send a fax 

justine% faxstat
Server on localhost:FIFO for all modems: Running.

Job  Modem Destination     Time-To-Send     Sender         Status
1    any   +17039180498    23:22 1996/04/27 Robert Nichols Queued and waiting
justine% 

Apr 27 23:22:29 justine FaxQueuer[191]: SUBMIT JOB "sendq/q1"
Apr 27 23:22:37 justine FaxSend[353]: /dev/cuaa1: Can not deduce modem type.

My modem config file is as follows 

# $Header: /usr/people/sam/fax/./config/RCS/zyxel-1496e-2.0,v 1.14 1995/04/08 21:25:03 sam Rel $
#
# HylaFAX Facsimile Software
#
# Copyright (c) 1990-1995 Sam Leffler
# Copyright (c) 1991-1995 Silicon Graphics, Inc.
# HylaFAX is a trademark of Silicon Graphics, Inc.
# 
# Permission to use, copy, modify, distribute, and sell this software and 
# its documentation for any purpose is hereby granted without fee, provided
# that (i) the above copyright notices and this permission notice appear in
# all copies of the software and related documentation, and (ii) the names of
# Sam Leffler and Silicon Graphics may not be used in any advertising or
# publicity relating to the software without the specific, prior written
# permission of Sam Leffler and Silicon Graphics.
# 
# THE SOFTWARE IS PROVIDED "AS-IS" AND WITHOUT WARRANTY OF ANY KIND, 
# EXPRESS, IMPLIED OR OTHERWISE, INCLUDING WITHOUT LIMITATION, ANY 
# WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.  
# 
# IN NO EVENT SHALL SAM LEFFLER OR SILICON GRAPHICS BE LIABLE FOR
# ANY SPECIAL, INCIDENTAL, INDIRECT OR CONSEQUENTIAL DAMAGES OF ANY KIND,
# OR ANY DAMAGES WHATSOEVER RESULTING FROM LOSS OF USE, DATA OR PROFITS,
# WHETHER OR NOT ADVISED OF THE POSSIBILITY OF DAMAGE, AND ON ANY THEORY OF 
# LIABILITY, ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE 
# OF THIS SOFTWARE.
#

#
# Configuration for a ZyXEL-1496E w/ Class 2.0 firmware.
# Firmware revisions from 6.12 on should work.
#
# This configuration file sets up the ZyXEL to run at 38.4 for
# both sending and receiving.  RTS/CTS flow control is used on
# the tty port--you probably shouldn't use XON/XOFF.  Note that
# on an SGI system the getty speed is the following non-standard
# gettydefs entry:
#
# dx_38400# B38400 # B38400 SANE TAB3 HUPCL #\r\n\n$HOSTNAME login: #dx_38400
#
#
CountryCode:		1
AreaCode:		703
FAXNumber:		+1.703.560.4121
LongDistancePrefix:	1
InternationalPrefix:	011
DialStringRules:	etc/dialrules
ServerTracing:		1
SessionTracing:		11
RecvFileMode:		00600
LogFileMode:		00600
DeviceMode:		00600
RingsBeforeAnswer:	1
SpeakerVolume:		off
GettyArgs:		"-h %l dx_%s"
LocalIdentifier:	+17035604121
TagLineFont:		etc/lutRS18.pcf
TagLineFormat:		"From %%l|%c|Page %%p of %%t"
NoCarrierRetrys:	3
MaxRecvPages:		25
#
#
# Modem-related stuff: should reflect modem command interface
# and hardware connection/cabling (e.g. flow control).
#
ModemType:		Class2.0	# use class 2.0 interface
ModemRate:		38400		# 38.4 works fine
ModemFlowControl:	rtscts		# default
#
ModemNoFlowCmd:		AT&H0		# disable flow control
ModemHardFlowCmd:	AT&H3		# hardware flow control
ModemSoftFlowCmd:	AT&H4		# software flow control
ModemSetupDTRCmd:	AT&D2		# DTR off causes modem to hang up
ModemSetupDCDCmd:	AT&C1		# DCD tracks carrier
#
ModemSetupAACmd:	AT+FAA=1	# enable in current class
#
# Additional reset commands:
#
# &B1	  DTE-DCE rate is fixed at DTE setting
# &N0	  Auto-negotiate highest possible DCE-DCE link rate
# &S0	  DSR always on
# *F0	  Deny remote configuration
# S18=2	  Receive at 38400
# S38.3=1 DCD on/off sequence follows UNIX standard; also
#	  fix receiving baud rate at S18 value
# S39=0	  (avoid Class 2 compatibility hacks)
# 
ModemResetCmds:		AT&B1&N0&S0*F0S18=2S38.3=1S39=0
#
ModemDialCmd:		ATDT%s		# no '@' 'cuz then busy not recognized
NoCarrierRetrys:	3		# retry 3 times on no carrier
#
ModemSetVolumeCmd:	"ATM0 ATM1L1 ATM1L3 ATM1L5 ATM1L7"
#
# Caller ID configuration setup.
#
#QualifyCID:		etc/cid		# CID access control list file
#CIDNumber:		"CALLER NUMBER: " # pattern string for phone number info
#CIDName:		"CALLER NAME: "	# pattern string for identity info
#
PagerSetupCmds:		AT&K0&N15	# use V.22 at 1200 bps (PageNet)

-------------------------------------------------------------------------------

Here's my general config file..

LogFacility:		daemon
CountryCode:		1
AreaCode:		703
LongDistancePrefix:	1
InternationalPrefix:	011
DialStringRules:	etc/dialrules
ServerTracing:		1

-------------------------------------------------------------------------------

Anybody know why it's complaining?

Also, when I faxrm the job I get back a message but it says that "No
transcript is available"

How can I log the session to the modem so I can diagnose the problem?



Want to link to this message? Use this URL: <https://mail-archive.FreeBSD.org/cgi/mid.cgi?199604280339.XAA00449>