Skip site navigation (1)Skip section navigation (2)
Date:      Mon, 17 Dec 2018 16:52:22 +0100
From:      Mark Martinec <Mark.Martinec+freebsd@ijs.si>
To:        freebsd-stable@freebsd.org
Subject:   mps and LSI SAS2308: controller resets on 12.0 - IOC Fault 0x40000d04, Resetting
Message-ID:  <515deae15368aaa8c8deb241e71f87db@ijs.si>

next in thread | raw e-mail | index | archive | help
One of our servers that was upgraded from 11.2 to 12.0 (to RC2 
initially, then to RC3
and lastly to a 12.0-RELEASE) is suffering severe instability of a disk 
controller,
resetting itself a couple of times a day, usually associated with high 
disk usage
(like poudriere buils or zfs scrub or nightly file system scans). The 
same setup
was rock-solid under 11.2 (and still/again is).

The disk controller is LSI SAS2308. It has four disks attached as JBODs,
one pair of SSDs and one pair of hard disks, each pair forming its own 
zpool.
A controller reset can occur regardless of which pair is in heavy use.

The following can be found in logs, just before machine becomes unusable
(although not logged always, as disks may be dropped before syslog has a 
chance
of writing anything):

   xxx kernel: [2382] mps0: IOC Fault 0x40000d04, Resetting
   xxx kernel: [2382] mps0: Reinitializing controller
   xxx kernel: [2383] mps0: Firmware: 20.00.02.00, Driver: 
21.02.00.00-fbsd
   xxx kernel: [2383] mps0: IOCCapabilities: 
5a85c<ScsiTaskFull,DiagTrace,SnapBuf,EEDP,TransRetry,EventReplay,MSIXIndex,HostDisc>
   xxx kernel: [2383] (da0:mps0:0:0:0): Invalidating pack

The IOC Fault location is always the same. Apparently the disk 
controller resets,
all disk devices are dropped and ZFS finds itself with no disks. The 
machine still
responds to ping, and if logged-in during the event and running zpool 
status -v 1,
zfs reports loss of all devices for each pool:

   pool: data0
  state: UNAVAIL
status: One or more devices are faulted in response to IO failures.
  action: Make sure the affected devices are connected, then run 'zpool 
clear'.
    see: http://illumos.org/msg/ZFS-8000-HC
    scan: scrub repaired 0 in 0 days 03:53:41 with 0 errors on Sat Nov 17 
00:22:38 2018
config:

         NAME                      STATE     READ WRITE CKSUM
         data0                     UNAVAIL      0     0     0
           mirror-0                UNAVAIL      0    24     0
              2396428274137360341   REMOVED      0     0     0  was 
/dev/gpt/da2-PN1334PCKAKD4S
              16738407333921736610  REMOVED      0     0     0  was 
/dev/gpt/da3-PN2338P4GJ1XYC

(and similar for the other pool)

At this point the machine is unusable and needs to be hard-reset.

My guess is that after the controller resets, disk devices come up again
(according to the report seen on the console, stating 'periph destroyed'
first, then listing full info on each disk) - but zfs ignores them.

I don't see any mention of changes of the mps driver in the 12.0 release 
notes,
although diff-ing its sources between 11.2 and 12.0 shows plenty of 
nontrivial
changes.

After suffering this instability for some time, I finally downgraded the 
OS
to 11.2, and things are back to normal again!

This downgrade path was nontrivial, as I have foolishly upgraded pool 
features
to what comes with 12.0, so downgrading involved hacking with 
dismantling
both zfs mirror pools, recreating pools without the two new features,
zfs send/receive copying, while having a machine hang during some of
these operations. Not something for the faint at heart. I know, foolish
of me to upgrade pools after just one day of uptime with 12.0.

Some info on the controller:

kernel: mps0: <Avago Technologies (LSI) SAS2308> port 0xf000-0xf0ff mem 
0xfbe40000-
   0xfbe4ffff,0xfbe00000-0xfbe3ffff irq 64 at device 0.0 numa-domain 1 on 
pci11
kernel: mps0: Firmware: 20.00.02.00, Driver: 21.02.00.00-fbsd

mpsutil shows:

   mps0 Adapter:
     Board Name: LSI2308-IT
     Board Assembly:
     Chip Name: LSISAS2308
     Chip Revision: ALL
     BIOS Revision: 7.39.00.00
     Firmware Revision: 20.00.02.00
     Integrated RAID: no


So, what has changed in the mps driver for this to be happening?
Would it be possible to take mps driver sources from 11.2, transplant
them to 12.0, recompile, and use that? Could the new mps driver be
using some new feature of the controller and hits a firmware bug?
I have resisted upgrading SAS2308 firmware and its BIOS, as it is
working very well under 11.2.

Anyone else seen problems with mps driver and LSI SAS2308 controller?

(btw, on another machine the mps driver with LSI SAS2004 is working
just fine under 12.0)