Skip site navigation (1)Skip section navigation (2)
Date:      Sun, 17 Jan 2010 14:32:21 +0100
From:      "Ronald Klop" <ronald-freebsd8@klop.yi.org>
To:        "Marin Atanasov" <dnaeon@gmail.com>, freebsd-hardware@freebsd.org
Cc:        freebsd-stable@freebsd.org
Subject:   Re: Multiple serial consoles via null modem cable
Message-ID:  <op.u6oij7dz8527sy@212-123-145-58.ip.telfort.nl>
In-Reply-To: <717f7a3e1001142234y1de7ae15x6853e3ddcab4add9@mail.gmail.com>
References:  <717f7a3e1001120714m37aada69gfaa35f0f9b17f435@mail.gmail.com> <44678539@bb.ipt.ru> <717f7a3e1001142234y1de7ae15x6853e3ddcab4add9@mail.gmail.com>

next in thread | previous in thread | raw e-mail | index | archive | help
On Fri, 15 Jan 2010 07:34:17 +0100, Marin Atanasov <dnaeon@gmail.com> =20
wrote:

> Thank you a lot for your feedback!
>
> Now to the real question again, because I'm a little confused now - can=
 I
> still get a usb-to-serial port converter having let's say 8 serial port=
s =20
> and
> then connect each machine to the usb-to-serial hub and manage them =20
> remotely
> from a single location (the host having the usb-to-serial hub)? That wa=
y =20
> I
> just specify a serial port number and I get to a specific machine?
>
> The model provided by Boris looks nice, and that was my initial idea, b=
ut
> I'm not sure if I could get it working under FreeBSD. Is conserver or
> conserver-com able to handle this? I know that cu uses COM1 only, but =20
> will
> conserver able to handle serial consoles on different ports, since the
> usb-to-serial port would appear as multiple serial ports.

You can provide cu with the port to connect to on the command line.

cu -l cuaU0 -s 115200
cu -l cuaU1 -s 115200
etc.

You can not connect several servers on 1 serial port, but you can connect=
 =20
several servers on several serial ports. With serial-over-usb it scales t=
o =20
many serial ports.

Ronald.


>
> Thank you and regards,
> Marin
>
>
> On Tue, Jan 12, 2010 at 7:04 PM, Boris Samorodov <bsam@ipt.ru> wrote:
>
>> On Tue, 12 Jan 2010 17:14:44 +0200 Marin Atanasov wrote:
>>
>> > I'm thinking about the following situation - 1 system acting like a =
=20
>> host
>> > with a serial port hub, each port of the hub is connected to a =20
>> different
>> > machine on sio0, using null modem cables.
>>
>> Along with milti-io serial cards we use multi-usb serial
>> converters, such as SUNIX UTS7009P (7 USB to serial adapter):
>> http://www.sunix.com.tw/it/en/LinkCraft/UTS4009P_UTS7009P.htm
>>
>> --
>> WBR, Boris Samorodov (bsam)
>> Research Engineer, http://www.ipt.ru Telephone & Internet SP
>> FreeBSD Committer, http://www.FreeBSD.org The Power To Serve
>>
>
>
>




Want to link to this message? Use this URL: <https://mail-archive.FreeBSD.org/cgi/mid.cgi?op.u6oij7dz8527sy>