Date: Fri, 18 Mar 2005 16:29:15 +0100 (CET) From: Harti Brandt <hartmut.brandt@dlr.de> To: Teva AVRIL <teva.avril@esigetel.fr> Cc: freebsd-atm@freebsd.org Subject: Re: about vp range on fore PCA-200e ATM cards Message-ID: <20050318162715.Q50366@beagle.kn.op.dlr.de> In-Reply-To: <3702.193.49.124.107.1111055066.squirrel@mercure.esigetel.fr> References: <3702.193.49.124.107.1111055066.squirrel@mercure.esigetel.fr>
next in thread | previous in thread | raw e-mail | index | archive | help
On Thu, 17 Mar 2005, Teva AVRIL wrote: TA>i have a station with an ATM card PCA-200e. i'd like to use it on a VP 92. TA>The problem is that this card support only VP 0. TA> TA>I'd like to know if it's possible to shift vp range, to be able to use TA>this card on VP 92. The official answer is: no. It might be possible by patching the firmware, but I never tried this. Fore even reserved an OP code SetVPI, but I never saw a firmware that implemented this. If you absolutly need this better get an HE155. I got a couple of them at ebay for $10. harti
Want to link to this message? Use this URL: <https://mail-archive.FreeBSD.org/cgi/mid.cgi?20050318162715.Q50366>