Date:      Wed, 21 May 2008 07:52:59 +1000
From:      Andrew Snow <andrew@modulus.org>
To:        freebsd-scsi@freebsd.org
Subject:   Re: Very poor performance from Dell/LSI Logic SAS 3000 series SATA/SAS RAID controller FreeBSD 6.3
Message-ID:  <4833483B.4030208@modulus.org>
In-Reply-To: <4832E6C2.7040205@calorieking.com>
References:  <4832C397.3090004@calorieking.com> <4832E0EE.3030402@samsco.org> <4832E6C2.7040205@calorieking.com>

next in thread | previous in thread | raw e-mail | index | archive | help
Warren Guy wrote:
> Thanks a lot for that. This seems to have alleviated the problem, I'm seeing
> decent performance now in my limited benchmark. It seems quite odd to me that
> the write cache is not enabled by default, but oh well.

Technically with UFS, it can lead to filesystem or database corruption - 
when the power goes off suddenly, the OS+controller thinks the data has 
been written, but the drive has it in cache that is not battery-backed.




Want to link to this message? Use this URL: <https://mail-archive.FreeBSD.org/cgi/mid.cgi?4833483B.4030208>