Skip site navigation (1)Skip section navigation (2)
Date:      Fri, 25 Mar 2011 14:10:13 -0700
From:      Freddie Cash <fjwcash@gmail.com>
To:        Rumen Telbizov <telbizov@gmail.com>
Cc:        Denny Schierz <linuxmail@4lin.net>, freebsd-stable <freebsd-stable@freebsd.org>
Subject:   Re: SAS HBA LSI 9200-8e supported under 8.2?
Message-ID:  <AANLkTinmnOtLisOeGkmjCsLU6b=pqauzv_cLvLW8QgFm@mail.gmail.com>
In-Reply-To: <AANLkTincriB%2B4%2B4H4hqhwWj_u3JABm6DpBzKSCbGboh9@mail.gmail.com>
References:  <1300618959.2191.5.camel@netti> <AANLkTi=8%2BrM9CJUd2ACB8U1QA9LzBwcwBLg0LjAwOTpH@mail.gmail.com> <1300887484.5930.72.camel@pcdenny> <AANLkTinGw0Lbnhu%2Bbo01RiRgPN1TpBouG1XdxM4T9ZOz@mail.gmail.com> <8CDBE9B8-4834-4F2C-84B9-2DA371D5B2C3@4lin.net> <AANLkTik8NmvRdH_SfXzcvTxVvhy8n77Q80hbaXniLFBQ@mail.gmail.com> <1301056115.21588.103.camel@pcdenny> <AANLkTikxOiq_H9M_EU6dLAQ3jt=8ynaD_dyCs2t5-7rL@mail.gmail.com> <AANLkTincriB%2B4%2B4H4hqhwWj_u3JABm6DpBzKSCbGboh9@mail.gmail.com>

next in thread | previous in thread | raw e-mail | index | archive | help
On Fri, Mar 25, 2011 at 8:47 AM, Rumen Telbizov <telbizov@gmail.com> wrote:
> On Fri, Mar 25, 2011 at 7:38 AM, Freddie Cash <fjwcash@gmail.com> wrote:
>> On Fri, Mar 25, 2011 at 5:28 AM, Denny Schierz <linuxmail@4lin.net> wrot=
e:
>> > So, how complicated is load balancing with two Gb Network cards? :-) O=
k,
>> > that should be a new thread;-)
>>
>> Simple as pie. =C2=A0Read through lagg(4) to see how it's done from the
>> command-line using ifconfig(8).
>>
>> ifconfig_lagg0=3D"laggproto round-robin laggport em0 laggport em1 inet
>> 192.168.0.1/24"
>
> That's actually an interesting problem (although it really belongs to a
> different thread).
> Freddie, have you tried this with an HP Procurve (say 2910al) switch.
> I did and a dual gigabit connection between two machines made the switch
> cpu utilization to jump from around 1% to 30%. I guess it might be HP
> specific problem due to the enormous mac address bounce between the two
> ports. I am curious to know if anybody else has experienced similar
> problems?

Yes, using LACP trunking on the switch and lagg(4).  I'll have to
double-check the exact switch models but I believe one is a 2910 and
the other is a 28-something.

I've also done it using load-balance and fail-over using unmanaged
switch ports.  Never used round-robin, though.

--=20
Freddie Cash
fjwcash@gmail.com



Want to link to this message? Use this URL: <https://mail-archive.FreeBSD.org/cgi/mid.cgi?AANLkTinmnOtLisOeGkmjCsLU6b=pqauzv_cLvLW8QgFm>