>Hello!
>Guys I've got a problem with Intel Etherexpress Pro.
>It works VERY slow (30-40 KB/sec).
>The adapter is plugged in a Catalyst switch, so IMO it must be OK with
>autoneg protocols.

   Cisco switches typically don't autonegotiate correctly. You'll need to
force both ends to 100/full (or whatever) in order to set the correct mode.
Something like "ifconfig fxp0 media 100basetx mediaopt full-duplex"