Skip site navigation (1)Skip section navigation (2)
Date:      Wed, 12 Jun 1996 20:09:37 -0700 (PDT)
From:      Steve Khoo <steve@gordian.com>
To:        davidg@Root.COM
Cc:        freebsd-hardware@FreeBSD.org, freebsd-hackers@FreeBSD.org
Subject:   Re: 2.2-960501-SNAP and Digital DC21041 Ethernet - some errors. 
Message-ID:  <199606130309.UAA16639@delphi.gordian.com>
In-Reply-To: David Greenman's message of Wed, 12 Jun 1996 19:16:39 -0700
References:  <199606130152.SAA15400@delphi.gordian.com> <199606130216.TAA00298@Root.COM>

next in thread | previous in thread | raw e-mail | index | archive | help
>>>>> "David" == David Greenman <davidg@Root.COM> writes:

    >> I got a similar problem in 2.2-960501-SNAP.  The SMC Etherpower 10/100
    >> cards in my P6 keep coming up in 100BaseT while it's only connected to
    >> 10BaseT network.  It's happening more than 50% during reboot.  It's
    >> getting worse now since we have two of those cards in the system now.
    >> Is there a way to force it to do 10BaseT instead?

    David>    Yes, use the link2 flag to ifconfig. I think "link2"
    David>    forces 100Mbps and
    David> "-link2" forces 10Mbps.

Thanks! It works. '-link2' forces 10Mbps.



Want to link to this message? Use this URL: <https://mail-archive.FreeBSD.org/cgi/mid.cgi?199606130309.UAA16639>