Skip site navigation (1)Skip section navigation (2)
Date:      Mon, 8 Dec 2014 10:58:14 -0500
From:      Justin O'Conor <oconnor@crystal.harvard.edu>
To:        Alan Somers <asomers@freebsd.org>
Cc:        FreeBSD-scsi <freebsd-scsi@freebsd.org>
Subject:   Re: LSI SAS 3008 card - 35 out of 36 disks detected
Message-ID:  <DD7EC4AD-A4B6-46F7-8F1C-9AD111DF20C6@crystal.harvard.edu>
In-Reply-To: <CAOtMX2j8K3aKST1mZ%2BEMKo4OVKiR6MUy%2B1VBQ1rMams5h7Hy_w@mail.gmail.com>
References:  <54822835.3080800@crystal.harvard.edu> <CAOtMX2j8K3aKST1mZ%2BEMKo4OVKiR6MUy%2B1VBQ1rMams5h7Hy_w@mail.gmail.com>

next in thread | previous in thread | raw e-mail | index | archive | help
Hi All,
Thanks, this is encouraging. smp_discover ses0|1 see 36 sata disks. This =
is from the 10.1 install.

Lets start with the short ones -
root@rhea:~ # sg_inq --hex --len=3D64 ses0
 00     0d 00 05 02 34 00 40 02  4c 53 49 20 20 20 20 20    ....4.@.LSI  =
  =20
 10     53 41 53 32 58 33 36 20  20 20 20 20 20 20 20 20    SAS2X36      =
  =20
 20     30 65 31 32 78 33 36 2d  35 35 2e 31 34 2e 31 38    =
0e12x36-55.14.18
 30     2e 30 00 20 20 20 20 20                             .0.    =20
root@rhea:~ # sg_inq --hex --len=3D64 ses1
 00     0d 00 05 02 34 00 40 02  4c 53 49 20 20 20 20 20    ....4.@.LSI  =
  =20
 10     53 41 53 32 58 32 38 20  20 20 20 20 20 20 20 20    SAS2X28      =
  =20
 20     30 65 31 32 78 33 36 2d  35 35 2e 31 34 2e 31 38    =
0e12x36-55.14.18
 30     2e 30 00 20 20 20 20 20=20


root@rhea:~ # smp_discover ses0
  phy   0:S:attached:[500605b009150c20:02  i(SSP+STP+SMP)]  6 Gbps
  phy   1:S:attached:[500605b009150c20:03  i(SSP+STP+SMP)]  6 Gbps
  phy   2:S:attached:[500605b009150c20:01  i(SSP+STP+SMP)]  6 Gbps
  phy   3:S:attached:[500605b009150c20:00  i(SSP+STP+SMP)]  6 Gbps
  phy   4:U:attached:[50030480017bd5bf:00 exp t(SMP)]  6 Gbps
  phy   5:U:attached:[50030480017bd5bf:01 exp t(SMP)]  6 Gbps
  phy   6:U:attached:[50030480017bd5bf:02 exp t(SMP)]  6 Gbps
  phy   7:U:attached:[50030480017bd5bf:03 exp t(SMP)]  6 Gbps
  phy  12:U:attached:[50030480017ae20c:00  t(SATA)]  6 Gbps
  phy  13:U:attached:[50030480017ae20d:00  t(SATA)]  6 Gbps
  phy  14:U:attached:[50030480017ae20e:00  t(SATA)]  6 Gbps
  phy  15:U:attached:[50030480017ae20f:00  t(SATA)]  6 Gbps
  phy  16:U:attached:[50030480017ae210:00  t(SATA)]  6 Gbps
  phy  17:U:attached:[50030480017ae211:00  t(SATA)]  6 Gbps
  phy  18:U:attached:[50030480017ae212:00  t(SATA)]  6 Gbps
  phy  19:U:attached:[50030480017ae213:00  t(SATA)]  6 Gbps
  phy  20:U:attached:[50030480017ae214:00  t(SATA)]  6 Gbps
  phy  21:U:attached:[50030480017ae215:00  t(SATA)]  6 Gbps
  phy  22:U:attached:[50030480017ae216:00  t(SATA)]  6 Gbps
  phy  23:U:attached:[50030480017ae217:00  t(SATA)]  6 Gbps
  phy  24:U:attached:[50030480017ae218:00  t(SATA)]  6 Gbps
  phy  25:U:attached:[50030480017ae219:00  t(SATA)]  6 Gbps
  phy  26:U:attached:[50030480017ae21a:00  t(SATA)]  6 Gbps
  phy  27:U:attached:[50030480017ae21b:00  t(SATA)]  6 Gbps
  phy  28:U:attached:[50030480017ae21c:00  t(SATA)]  6 Gbps
  phy  29:U:attached:[50030480017ae21d:00  t(SATA)]  6 Gbps
  phy  30:U:attached:[50030480017ae21e:00  t(SATA)]  6 Gbps
  phy  31:U:attached:[50030480017ae21f:00  t(SATA)]  6 Gbps
  phy  32:U:attached:[50030480017ae220:00  t(SATA)]  6 Gbps
  phy  33:U:attached:[50030480017ae221:00  t(SATA)]  6 Gbps
  phy  34:U:attached:[50030480017ae222:00  t(SATA)]  6 Gbps
  phy  35:U:attached:[50030480017ae223:00  t(SATA)]  6 Gbps
  phy  36:D:attached:[50030480017ae23d:00  V i(SSP+SMP) t(SSP)]  6 Gbps
root@rhea:~ #  foreach PHY ( `seq 0 1 36` )
foreach?  smp_discover -p $PHY ses0
foreach? end
Discover response:
  expander change count: 1328
  phy identifier: 0
  attached device type: SAS or SATA device
  attached reason: power on
  negotiated logical link rate: phy enabled, 6 Gbps
  attached initiator: ssp=3D1 stp=3D1 smp=3D1 sata_host=3D0
  attached sata port selector: 0
  STP buffer too small: 0
  attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D0
  SAS address: 0x50030480017ae23f
  attached SAS address: 0x500605b009150c20
  attached phy identifier: 2
  attached persistent capable: 0
  attached power capable: 0
  attached slumber capable: 0
  attached partial capable: 0
  attached inside ZPSDS persistent: 0
  attached requested inside ZPSDS: 0
  attached break_reply capable: 1
  attached pwr_dis capable: 0
  programmed minimum physical link rate: 1.5 Gbps
  hardware minimum physical link rate: 1.5 Gbps
  programmed maximum physical link rate: 6 Gbps
  hardware maximum physical link rate: 6 Gbps
  phy change count: 33
  virtual phy: 0
  partial pathway timeout value: 7 us
  routing attribute: subtractive
  connector type: No information
  connector element index: 0
  connector physical link: 0
  phy power condition: 0
  sas power capable: 0
  sas slumber capable: 0
  sas partial capable: 0
  sata slumber capable: 0
  sata partial capable: 0
  pwr_dis signal: 0
  pwr_dis control capable: 0
  sas slumber enabled: 0
  sas partial enabled: 0
  sata slumber enabled: 0
  sata partial enabled: 0
  attached device name: 0x500605b009150c20
  requested inside ZPSDS changed by expander: 0
  inside ZPSDS persistent: 0
  requested inside ZPSDS: 0
  zone group persistent: 1
  inside ZPSDS: 0
  zoning enabled: 0
  zone group: 1
  self-configuration status: 0
  self-configuration levels completed: 0
  self-configuration sas address: 0x0
  programmed phy capabilities: 0x0
  current phy capabilities: 0x0
  attached phy capabilities: 0x0
  reason: unknown
  negotiated physical link rate: phy enabled, 6 Gbps
  optical mode enabled: 0
  negotiated SSC: 0
  hardware muxing supported: 0
  default inside ZPSDS persistent: 0
  default requested inside ZPSDS: 0
  default zone group persistent: 1
  default zoning enabled: 0
  default zone group: 1
  saved inside ZPSDS persistent: 0
  saved requested inside ZPSDS: 0
  saved zone group persistent: 1
  saved zoning enabled: 0
  saved zone group: 1
  shadow inside ZPSDS persistent: 0
  shadow requested inside ZPSDS: 0
  shadow zone group persistent: 1
  shadow zoning enabled: 0
  shadow zone group: 1
  device slot number: 255
  device slot group number: 255
  device slot group output connector:      =20
Discover response:
  expander change count: 1328
  phy identifier: 1
  attached device type: SAS or SATA device
  attached reason: power on
  negotiated logical link rate: phy enabled, 6 Gbps
  attached initiator: ssp=3D1 stp=3D1 smp=3D1 sata_host=3D0
  attached sata port selector: 0
  STP buffer too small: 0
  attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D0
  SAS address: 0x50030480017ae23f
  attached SAS address: 0x500605b009150c20
  attached phy identifier: 3
  attached persistent capable: 0
  attached power capable: 0
  attached slumber capable: 0
  attached partial capable: 0
  attached inside ZPSDS persistent: 0
  attached requested inside ZPSDS: 0
  attached break_reply capable: 1
  attached pwr_dis capable: 0
  programmed minimum physical link rate: 1.5 Gbps
  hardware minimum physical link rate: 1.5 Gbps
  programmed maximum physical link rate: 6 Gbps
  hardware maximum physical link rate: 6 Gbps
  phy change count: 33
  virtual phy: 0
  partial pathway timeout value: 7 us
  routing attribute: subtractive
  connector type: No information
  connector element index: 0
  connector physical link: 0
  phy power condition: 0
  sas power capable: 0
  sas slumber capable: 0
  sas partial capable: 0
  sata slumber capable: 0
  sata partial capable: 0
  pwr_dis signal: 0
  pwr_dis control capable: 0
  sas slumber enabled: 0
  sas partial enabled: 0
  sata slumber enabled: 0
  sata partial enabled: 0
  attached device name: 0x500605b009150c20
  requested inside ZPSDS changed by expander: 0
  inside ZPSDS persistent: 0
  requested inside ZPSDS: 0
  zone group persistent: 1
  inside ZPSDS: 0
  zoning enabled: 0
  zone group: 1
  self-configuration status: 0
  self-configuration levels completed: 0
  self-configuration sas address: 0x0
  programmed phy capabilities: 0x0
  current phy capabilities: 0x0
  attached phy capabilities: 0x0
  reason: unknown
  negotiated physical link rate: phy enabled, 6 Gbps
  optical mode enabled: 0
  negotiated SSC: 0
  hardware muxing supported: 0
  default inside ZPSDS persistent: 0
  default requested inside ZPSDS: 0
  default zone group persistent: 1
  default zoning enabled: 0
  default zone group: 1
  saved inside ZPSDS persistent: 0
  saved requested inside ZPSDS: 0
  saved zone group persistent: 1
  saved zoning enabled: 0
  saved zone group: 1
  shadow inside ZPSDS persistent: 0
  shadow requested inside ZPSDS: 0
  shadow zone group persistent: 1
  shadow zoning enabled: 0
  shadow zone group: 1
  device slot number: 255
  device slot group number: 255
  device slot group output connector:      =20
Discover response:
  expander change count: 1328
  phy identifier: 2
  attached device type: SAS or SATA device
  attached reason: power on
  negotiated logical link rate: phy enabled, 6 Gbps
  attached initiator: ssp=3D1 stp=3D1 smp=3D1 sata_host=3D0
  attached sata port selector: 0
  STP buffer too small: 0
  attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D0
  SAS address: 0x50030480017ae23f
  attached SAS address: 0x500605b009150c20
  attached phy identifier: 1
  attached persistent capable: 0
  attached power capable: 0
  attached slumber capable: 0
  attached partial capable: 0
  attached inside ZPSDS persistent: 0
  attached requested inside ZPSDS: 0
  attached break_reply capable: 1
  attached pwr_dis capable: 0
  programmed minimum physical link rate: 1.5 Gbps
  hardware minimum physical link rate: 1.5 Gbps
  programmed maximum physical link rate: 6 Gbps
  hardware maximum physical link rate: 6 Gbps
  phy change count: 33
  virtual phy: 0
  partial pathway timeout value: 7 us
  routing attribute: subtractive
  connector type: No information
  connector element index: 0
  connector physical link: 0
  phy power condition: 0
  sas power capable: 0
  sas slumber capable: 0
  sas partial capable: 0
  sata slumber capable: 0
  sata partial capable: 0
  pwr_dis signal: 0
  pwr_dis control capable: 0
  sas slumber enabled: 0
  sas partial enabled: 0
  sata slumber enabled: 0
  sata partial enabled: 0
  attached device name: 0x500605b009150c20
  requested inside ZPSDS changed by expander: 0
  inside ZPSDS persistent: 0
  requested inside ZPSDS: 0
  zone group persistent: 1
  inside ZPSDS: 0
  zoning enabled: 0
  zone group: 1
  self-configuration status: 0
  self-configuration levels completed: 0
  self-configuration sas address: 0x0
  programmed phy capabilities: 0x0
  current phy capabilities: 0x0
  attached phy capabilities: 0x0
  reason: unknown
  negotiated physical link rate: phy enabled, 6 Gbps
  optical mode enabled: 0
  negotiated SSC: 0
  hardware muxing supported: 0
  default inside ZPSDS persistent: 0
  default requested inside ZPSDS: 0
  default zone group persistent: 1
  default zoning enabled: 0
  default zone group: 1
  saved inside ZPSDS persistent: 0
  saved requested inside ZPSDS: 0
  saved zone group persistent: 1
  saved zoning enabled: 0
  saved zone group: 1
  shadow inside ZPSDS persistent: 0
  shadow requested inside ZPSDS: 0
  shadow zone group persistent: 1
  shadow zoning enabled: 0
  shadow zone group: 1
  device slot number: 255
  device slot group number: 255
  device slot group output connector:      =20
Discover response:
  expander change count: 1328
  phy identifier: 3
  attached device type: SAS or SATA device
  attached reason: power on
  negotiated logical link rate: phy enabled, 6 Gbps
  attached initiator: ssp=3D1 stp=3D1 smp=3D1 sata_host=3D0
  attached sata port selector: 0
  STP buffer too small: 0
  attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D0
  SAS address: 0x50030480017ae23f
  attached SAS address: 0x500605b009150c20
  attached phy identifier: 0
  attached persistent capable: 0
  attached power capable: 0
  attached slumber capable: 0
  attached partial capable: 0
  attached inside ZPSDS persistent: 0
  attached requested inside ZPSDS: 0
  attached break_reply capable: 1
  attached pwr_dis capable: 0
  programmed minimum physical link rate: 1.5 Gbps
  hardware minimum physical link rate: 1.5 Gbps
  programmed maximum physical link rate: 6 Gbps
  hardware maximum physical link rate: 6 Gbps
  phy change count: 33
  virtual phy: 0
  partial pathway timeout value: 7 us
  routing attribute: subtractive
  connector type: No information
  connector element index: 0
  connector physical link: 0
  phy power condition: 0
  sas power capable: 0
  sas slumber capable: 0
  sas partial capable: 0
  sata slumber capable: 0
  sata partial capable: 0
  pwr_dis signal: 0
  pwr_dis control capable: 0
  sas slumber enabled: 0
  sas partial enabled: 0
  sata slumber enabled: 0
  sata partial enabled: 0
  attached device name: 0x500605b009150c20
  requested inside ZPSDS changed by expander: 0
  inside ZPSDS persistent: 0
  requested inside ZPSDS: 0
  zone group persistent: 1
  inside ZPSDS: 0
  zoning enabled: 0
  zone group: 1
  self-configuration status: 0
  self-configuration levels completed: 0
  self-configuration sas address: 0x0
  programmed phy capabilities: 0x0
  current phy capabilities: 0x0
  attached phy capabilities: 0x0
  reason: unknown
  negotiated physical link rate: phy enabled, 6 Gbps
  optical mode enabled: 0
  negotiated SSC: 0
  hardware muxing supported: 0
  default inside ZPSDS persistent: 0
  default requested inside ZPSDS: 0
  default zone group persistent: 1
  default zoning enabled: 0
  default zone group: 1
  saved inside ZPSDS persistent: 0
  saved requested inside ZPSDS: 0
  saved zone group persistent: 1
  saved zoning enabled: 0
  saved zone group: 1
  shadow inside ZPSDS persistent: 0
  shadow requested inside ZPSDS: 0
  shadow zone group persistent: 1
  shadow zoning enabled: 0
  shadow zone group: 1
  device slot number: 255
  device slot group number: 255
  device slot group output connector:      =20
Discover response:
  expander change count: 1328
  phy identifier: 4
  attached device type: expander device
  attached reason: SMP phy control requested
  negotiated logical link rate: phy enabled, 6 Gbps
  attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0
  attached sata port selector: 0
  STP buffer too small: 0
  attached target: ssp=3D0 stp=3D0 smp=3D1 sata_device=3D0
  SAS address: 0x50030480017ae23f
  attached SAS address: 0x50030480017bd5bf
  attached phy identifier: 0
  attached persistent capable: 0
  attached power capable: 0
  attached slumber capable: 0
  attached partial capable: 0
  attached inside ZPSDS persistent: 0
  attached requested inside ZPSDS: 0
  attached break_reply capable: 1
  attached pwr_dis capable: 0
  programmed minimum physical link rate: 1.5 Gbps
  hardware minimum physical link rate: 1.5 Gbps
  programmed maximum physical link rate: 6 Gbps
  hardware maximum physical link rate: 6 Gbps
  phy change count: 4
  virtual phy: 0
  partial pathway timeout value: 7 us
  routing attribute: table
  connector type: No information
  connector element index: 0
  connector physical link: 0
  phy power condition: 0
  sas power capable: 0
  sas slumber capable: 0
  sas partial capable: 0
  sata slumber capable: 0
  sata partial capable: 0
  pwr_dis signal: 0
  pwr_dis control capable: 0
  sas slumber enabled: 0
  sas partial enabled: 0
  sata slumber enabled: 0
  sata partial enabled: 0
  attached device name: 0x50030480017bd5bf
  requested inside ZPSDS changed by expander: 0
  inside ZPSDS persistent: 0
  requested inside ZPSDS: 0
  zone group persistent: 1
  inside ZPSDS: 0
  zoning enabled: 0
  zone group: 1
  self-configuration status: 0
  self-configuration levels completed: 1
  self-configuration sas address: 0x0
  programmed phy capabilities: 0x0
  current phy capabilities: 0x0
  attached phy capabilities: 0x0
  reason: unknown
  negotiated physical link rate: phy enabled, 6 Gbps
  optical mode enabled: 0
  negotiated SSC: 0
  hardware muxing supported: 0
  default inside ZPSDS persistent: 0
  default requested inside ZPSDS: 0
  default zone group persistent: 1
  default zoning enabled: 0
  default zone group: 1
  saved inside ZPSDS persistent: 0
  saved requested inside ZPSDS: 0
  saved zone group persistent: 1
  saved zoning enabled: 0
  saved zone group: 1
  shadow inside ZPSDS persistent: 0
  shadow requested inside ZPSDS: 0
  shadow zone group persistent: 1
  shadow zoning enabled: 0
  shadow zone group: 1
  device slot number: 255
  device slot group number: 255
  device slot group output connector:      =20
Discover response:
  expander change count: 1328
  phy identifier: 5
  attached device type: expander device
  attached reason: SMP phy control requested
  negotiated logical link rate: phy enabled, 6 Gbps
  attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0
  attached sata port selector: 0
  STP buffer too small: 0
  attached target: ssp=3D0 stp=3D0 smp=3D1 sata_device=3D0
  SAS address: 0x50030480017ae23f
  attached SAS address: 0x50030480017bd5bf
  attached phy identifier: 1
  attached persistent capable: 0
  attached power capable: 0
  attached slumber capable: 0
  attached partial capable: 0
  attached inside ZPSDS persistent: 0
  attached requested inside ZPSDS: 0
  attached break_reply capable: 1
  attached pwr_dis capable: 0
  programmed minimum physical link rate: 1.5 Gbps
  hardware minimum physical link rate: 1.5 Gbps
  programmed maximum physical link rate: 6 Gbps
  hardware maximum physical link rate: 6 Gbps
  phy change count: 4
  virtual phy: 0
  partial pathway timeout value: 7 us
  routing attribute: table
  connector type: No information
  connector element index: 0
  connector physical link: 0
  phy power condition: 0
  sas power capable: 0
  sas slumber capable: 0
  sas partial capable: 0
  sata slumber capable: 0
  sata partial capable: 0
  pwr_dis signal: 0
  pwr_dis control capable: 0
  sas slumber enabled: 0
  sas partial enabled: 0
  sata slumber enabled: 0
  sata partial enabled: 0
  attached device name: 0x50030480017bd5bf
  requested inside ZPSDS changed by expander: 0
  inside ZPSDS persistent: 0
  requested inside ZPSDS: 0
  zone group persistent: 1
  inside ZPSDS: 0
  zoning enabled: 0
  zone group: 1
  self-configuration status: 0
  self-configuration levels completed: 1
  self-configuration sas address: 0x0
  programmed phy capabilities: 0x0
  current phy capabilities: 0x0
  attached phy capabilities: 0x0
  reason: unknown
  negotiated physical link rate: phy enabled, 6 Gbps
  optical mode enabled: 0
  negotiated SSC: 0
  hardware muxing supported: 0
  default inside ZPSDS persistent: 0
  default requested inside ZPSDS: 0
  default zone group persistent: 1
  default zoning enabled: 0
  default zone group: 1
  saved inside ZPSDS persistent: 0
  saved requested inside ZPSDS: 0
  saved zone group persistent: 1
  saved zoning enabled: 0
  saved zone group: 1
  shadow inside ZPSDS persistent: 0
  shadow requested inside ZPSDS: 0
  shadow zone group persistent: 1
  shadow zoning enabled: 0
  shadow zone group: 1
  device slot number: 255
  device slot group number: 255
  device slot group output connector:      =20
Discover response:
  expander change count: 1328
  phy identifier: 6
  attached device type: expander device
  attached reason: SMP phy control requested
  negotiated logical link rate: phy enabled, 6 Gbps
  attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0
  attached sata port selector: 0
  STP buffer too small: 0
  attached target: ssp=3D0 stp=3D0 smp=3D1 sata_device=3D0
  SAS address: 0x50030480017ae23f
  attached SAS address: 0x50030480017bd5bf
  attached phy identifier: 2
  attached persistent capable: 0
  attached power capable: 0
  attached slumber capable: 0
  attached partial capable: 0
  attached inside ZPSDS persistent: 0
  attached requested inside ZPSDS: 0
  attached break_reply capable: 1
  attached pwr_dis capable: 0
  programmed minimum physical link rate: 1.5 Gbps
  hardware minimum physical link rate: 1.5 Gbps
  programmed maximum physical link rate: 6 Gbps
  hardware maximum physical link rate: 6 Gbps
  phy change count: 4
  virtual phy: 0
  partial pathway timeout value: 7 us
  routing attribute: table
  connector type: No information
  connector element index: 0
  connector physical link: 0
  phy power condition: 0
  sas power capable: 0
  sas slumber capable: 0
  sas partial capable: 0
  sata slumber capable: 0
  sata partial capable: 0
  pwr_dis signal: 0
  pwr_dis control capable: 0
  sas slumber enabled: 0
  sas partial enabled: 0
  sata slumber enabled: 0
  sata partial enabled: 0
  attached device name: 0x50030480017bd5bf
  requested inside ZPSDS changed by expander: 0
  inside ZPSDS persistent: 0
  requested inside ZPSDS: 0
  zone group persistent: 1
  inside ZPSDS: 0
  zoning enabled: 0
  zone group: 1
  self-configuration status: 0
  self-configuration levels completed: 1
  self-configuration sas address: 0x0
  programmed phy capabilities: 0x0
  current phy capabilities: 0x0
  attached phy capabilities: 0x0
  reason: unknown
  negotiated physical link rate: phy enabled, 6 Gbps
  optical mode enabled: 0
  negotiated SSC: 0
  hardware muxing supported: 0
  default inside ZPSDS persistent: 0
  default requested inside ZPSDS: 0
  default zone group persistent: 1
  default zoning enabled: 0
  default zone group: 1
  saved inside ZPSDS persistent: 0
  saved requested inside ZPSDS: 0
  saved zone group persistent: 1
  saved zoning enabled: 0
  saved zone group: 1
  shadow inside ZPSDS persistent: 0
  shadow requested inside ZPSDS: 0
  shadow zone group persistent: 1
  shadow zoning enabled: 0
  shadow zone group: 1
  device slot number: 255
  device slot group number: 255
  device slot group output connector:      =20
Discover response:
  expander change count: 1328
  phy identifier: 7
  attached device type: expander device
  attached reason: SMP phy control requested
  negotiated logical link rate: phy enabled, 6 Gbps
  attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0
  attached sata port selector: 0
  STP buffer too small: 0
  attached target: ssp=3D0 stp=3D0 smp=3D1 sata_device=3D0
  SAS address: 0x50030480017ae23f
  attached SAS address: 0x50030480017bd5bf
  attached phy identifier: 3
  attached persistent capable: 0
  attached power capable: 0
  attached slumber capable: 0
  attached partial capable: 0
  attached inside ZPSDS persistent: 0
  attached requested inside ZPSDS: 0
  attached break_reply capable: 1
  attached pwr_dis capable: 0
  programmed minimum physical link rate: 1.5 Gbps
  hardware minimum physical link rate: 1.5 Gbps
  programmed maximum physical link rate: 6 Gbps
  hardware maximum physical link rate: 6 Gbps
  phy change count: 4
  virtual phy: 0
  partial pathway timeout value: 7 us
  routing attribute: table
  connector type: No information
  connector element index: 0
  connector physical link: 0
  phy power condition: 0
  sas power capable: 0
  sas slumber capable: 0
  sas partial capable: 0
  sata slumber capable: 0
  sata partial capable: 0
  pwr_dis signal: 0
  pwr_dis control capable: 0
  sas slumber enabled: 0
  sas partial enabled: 0
  sata slumber enabled: 0
  sata partial enabled: 0
  attached device name: 0x50030480017bd5bf
  requested inside ZPSDS changed by expander: 0
  inside ZPSDS persistent: 0
  requested inside ZPSDS: 0
  zone group persistent: 1
  inside ZPSDS: 0
  zoning enabled: 0
  zone group: 1
  self-configuration status: 0
  self-configuration levels completed: 1
  self-configuration sas address: 0x0
  programmed phy capabilities: 0x0
  current phy capabilities: 0x0
  attached phy capabilities: 0x0
  reason: unknown
  negotiated physical link rate: phy enabled, 6 Gbps
  optical mode enabled: 0
  negotiated SSC: 0
  hardware muxing supported: 0
  default inside ZPSDS persistent: 0
  default requested inside ZPSDS: 0
  default zone group persistent: 1
  default zoning enabled: 0
  default zone group: 1
  saved inside ZPSDS persistent: 0
  saved requested inside ZPSDS: 0
  saved zone group persistent: 1
  saved zoning enabled: 0
  saved zone group: 1
  shadow inside ZPSDS persistent: 0
  shadow requested inside ZPSDS: 0
  shadow zone group persistent: 1
  shadow zoning enabled: 0
  shadow zone group: 1
  device slot number: 255
  device slot group number: 255
  device slot group output connector:      =20
Discover response:
  expander change count: 1328
  phy identifier: 8
  attached device type: no device attached
  attached reason: unknown
  negotiated logical link rate: phy enabled; unknown
  attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0
  attached sata port selector: 0
  STP buffer too small: 0
  attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D0
  SAS address: 0x50030480017ae23f
  attached SAS address: 0x0
  attached phy identifier: 0
  attached persistent capable: 0
  attached power capable: 0
  attached slumber capable: 0
  attached partial capable: 0
  attached inside ZPSDS persistent: 0
  attached requested inside ZPSDS: 0
  attached break_reply capable: 0
  attached pwr_dis capable: 0
  programmed minimum physical link rate: 1.5 Gbps
  hardware minimum physical link rate: 1.5 Gbps
  programmed maximum physical link rate: 6 Gbps
  hardware maximum physical link rate: 6 Gbps
  phy change count: 1
  virtual phy: 0
  partial pathway timeout value: 7 us
  routing attribute: table
  connector type: No information
  connector element index: 0
  connector physical link: 0
  phy power condition: 0
  sas power capable: 0
  sas slumber capable: 0
  sas partial capable: 0
  sata slumber capable: 0
  sata partial capable: 0
  pwr_dis signal: 0
  pwr_dis control capable: 0
  sas slumber enabled: 0
  sas partial enabled: 0
  sata slumber enabled: 0
  sata partial enabled: 0
  attached device name: 0x0
  requested inside ZPSDS changed by expander: 0
  inside ZPSDS persistent: 0
  requested inside ZPSDS: 0
  zone group persistent: 1
  inside ZPSDS: 0
  zoning enabled: 0
  zone group: 1
  self-configuration status: 0
  self-configuration levels completed: 0
  self-configuration sas address: 0x0
  programmed phy capabilities: 0x0
  current phy capabilities: 0x0
  attached phy capabilities: 0x0
  reason: unknown
  negotiated physical link rate: phy enabled; unknown
  optical mode enabled: 0
  negotiated SSC: 0
  hardware muxing supported: 0
  default inside ZPSDS persistent: 0
  default requested inside ZPSDS: 0
  default zone group persistent: 1
  default zoning enabled: 0
  default zone group: 1
  saved inside ZPSDS persistent: 0
  saved requested inside ZPSDS: 0
  saved zone group persistent: 1
  saved zoning enabled: 0
  saved zone group: 1
  shadow inside ZPSDS persistent: 0
  shadow requested inside ZPSDS: 0
  shadow zone group persistent: 1
  shadow zoning enabled: 0
  shadow zone group: 1
  device slot number: 255
  device slot group number: 255
  device slot group output connector:      =20
Discover response:
  expander change count: 1328
  phy identifier: 9
  attached device type: no device attached
  attached reason: unknown
  negotiated logical link rate: phy enabled; unknown
  attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0
  attached sata port selector: 0
  STP buffer too small: 0
  attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D0
  SAS address: 0x50030480017ae23f
  attached SAS address: 0x0
  attached phy identifier: 0
  attached persistent capable: 0
  attached power capable: 0
  attached slumber capable: 0
  attached partial capable: 0
  attached inside ZPSDS persistent: 0
  attached requested inside ZPSDS: 0
  attached break_reply capable: 0
  attached pwr_dis capable: 0
  programmed minimum physical link rate: 1.5 Gbps
  hardware minimum physical link rate: 1.5 Gbps
  programmed maximum physical link rate: 6 Gbps
  hardware maximum physical link rate: 6 Gbps
  phy change count: 1
  virtual phy: 0
  partial pathway timeout value: 7 us
  routing attribute: table
  connector type: No information
  connector element index: 0
  connector physical link: 0
  phy power condition: 0
  sas power capable: 0
  sas slumber capable: 0
  sas partial capable: 0
  sata slumber capable: 0
  sata partial capable: 0
  pwr_dis signal: 0
  pwr_dis control capable: 0
  sas slumber enabled: 0
  sas partial enabled: 0
  sata slumber enabled: 0
  sata partial enabled: 0
  attached device name: 0x0
  requested inside ZPSDS changed by expander: 0
  inside ZPSDS persistent: 0
  requested inside ZPSDS: 0
  zone group persistent: 1
  inside ZPSDS: 0
  zoning enabled: 0
  zone group: 1
  self-configuration status: 0
  self-configuration levels completed: 0
  self-configuration sas address: 0x0
  programmed phy capabilities: 0x0
  current phy capabilities: 0x0
  attached phy capabilities: 0x0
  reason: unknown
  negotiated physical link rate: phy enabled; unknown
  optical mode enabled: 0
  negotiated SSC: 0
  hardware muxing supported: 0
  default inside ZPSDS persistent: 0
  default requested inside ZPSDS: 0
  default zone group persistent: 1
  default zoning enabled: 0
  default zone group: 1
  saved inside ZPSDS persistent: 0
  saved requested inside ZPSDS: 0
  saved zone group persistent: 1
  saved zoning enabled: 0
  saved zone group: 1
  shadow inside ZPSDS persistent: 0
  shadow requested inside ZPSDS: 0
  shadow zone group persistent: 1
  shadow zoning enabled: 0
  shadow zone group: 1
  device slot number: 255
  device slot group number: 255
  device slot group output connector:      =20
Discover response:
  expander change count: 1328
  phy identifier: 10
  attached device type: no device attached
  attached reason: unknown
  negotiated logical link rate: phy enabled; unknown
  attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0
  attached sata port selector: 0
  STP buffer too small: 0
  attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D0
  SAS address: 0x50030480017ae23f
  attached SAS address: 0x0
  attached phy identifier: 0
  attached persistent capable: 0
  attached power capable: 0
  attached slumber capable: 0
  attached partial capable: 0
  attached inside ZPSDS persistent: 0
  attached requested inside ZPSDS: 0
  attached break_reply capable: 0
  attached pwr_dis capable: 0
  programmed minimum physical link rate: 1.5 Gbps
  hardware minimum physical link rate: 1.5 Gbps
  programmed maximum physical link rate: 6 Gbps
  hardware maximum physical link rate: 6 Gbps
  phy change count: 1
  virtual phy: 0
  partial pathway timeout value: 7 us
  routing attribute: table
  connector type: No information
  connector element index: 0
  connector physical link: 0
  phy power condition: 0
  sas power capable: 0
  sas slumber capable: 0
  sas partial capable: 0
  sata slumber capable: 0
  sata partial capable: 0
  pwr_dis signal: 0
  pwr_dis control capable: 0
  sas slumber enabled: 0
  sas partial enabled: 0
  sata slumber enabled: 0
  sata partial enabled: 0
  attached device name: 0x0
  requested inside ZPSDS changed by expander: 0
  inside ZPSDS persistent: 0
  requested inside ZPSDS: 0
  zone group persistent: 1
  inside ZPSDS: 0
  zoning enabled: 0
  zone group: 1
  self-configuration status: 0
  self-configuration levels completed: 0
  self-configuration sas address: 0x0
  programmed phy capabilities: 0x0
  current phy capabilities: 0x0
  attached phy capabilities: 0x0
  reason: unknown
  negotiated physical link rate: phy enabled; unknown
  optical mode enabled: 0
  negotiated SSC: 0
  hardware muxing supported: 0
  default inside ZPSDS persistent: 0
  default requested inside ZPSDS: 0
  default zone group persistent: 1
  default zoning enabled: 0
  default zone group: 1
  saved inside ZPSDS persistent: 0
  saved requested inside ZPSDS: 0
  saved zone group persistent: 1
  saved zoning enabled: 0
  saved zone group: 1
  shadow inside ZPSDS persistent: 0
  shadow requested inside ZPSDS: 0
  shadow zone group persistent: 1
  shadow zoning enabled: 0
  shadow zone group: 1
  device slot number: 255
  device slot group number: 255
  device slot group output connector:      =20
Discover response:
  expander change count: 1328
  phy identifier: 11
  attached device type: no device attached
  attached reason: unknown
  negotiated logical link rate: phy enabled; unknown
  attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0
  attached sata port selector: 0
  STP buffer too small: 0
  attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D0
  SAS address: 0x50030480017ae23f
  attached SAS address: 0x0
  attached phy identifier: 0
  attached persistent capable: 0
  attached power capable: 0
  attached slumber capable: 0
  attached partial capable: 0
  attached inside ZPSDS persistent: 0
  attached requested inside ZPSDS: 0
  attached break_reply capable: 0
  attached pwr_dis capable: 0
  programmed minimum physical link rate: 1.5 Gbps
  hardware minimum physical link rate: 1.5 Gbps
  programmed maximum physical link rate: 6 Gbps
  hardware maximum physical link rate: 6 Gbps
  phy change count: 1
  virtual phy: 0
  partial pathway timeout value: 7 us
  routing attribute: table
  connector type: No information
  connector element index: 0
  connector physical link: 0
  phy power condition: 0
  sas power capable: 0
  sas slumber capable: 0
  sas partial capable: 0
  sata slumber capable: 0
  sata partial capable: 0
  pwr_dis signal: 0
  pwr_dis control capable: 0
  sas slumber enabled: 0
  sas partial enabled: 0
  sata slumber enabled: 0
  sata partial enabled: 0
  attached device name: 0x0
  requested inside ZPSDS changed by expander: 0
  inside ZPSDS persistent: 0
  requested inside ZPSDS: 0
  zone group persistent: 1
  inside ZPSDS: 0
  zoning enabled: 0
  zone group: 1
  self-configuration status: 0
  self-configuration levels completed: 0
  self-configuration sas address: 0x0
  programmed phy capabilities: 0x0
  current phy capabilities: 0x0
  attached phy capabilities: 0x0
  reason: unknown
  negotiated physical link rate: phy enabled; unknown
  optical mode enabled: 0
  negotiated SSC: 0
  hardware muxing supported: 0
  default inside ZPSDS persistent: 0
  default requested inside ZPSDS: 0
  default zone group persistent: 1
  default zoning enabled: 0
  default zone group: 1
  saved inside ZPSDS persistent: 0
  saved requested inside ZPSDS: 0
  saved zone group persistent: 1
  saved zoning enabled: 0
  saved zone group: 1
  shadow inside ZPSDS persistent: 0
  shadow requested inside ZPSDS: 0
  shadow zone group persistent: 1
  shadow zoning enabled: 0
  shadow zone group: 1
  device slot number: 255
  device slot group number: 255
  device slot group output connector:      =20
Discover response:
  expander change count: 1328
  phy identifier: 12
  attached device type: SAS or SATA device
  attached reason: unknown
  negotiated logical link rate: phy enabled, 6 Gbps
  attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0
  attached sata port selector: 0
  STP buffer too small: 0
  attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D1
  SAS address: 0x50030480017ae23f
  attached SAS address: 0x50030480017ae20c
  attached phy identifier: 0
  attached persistent capable: 0
  attached power capable: 0
  attached slumber capable: 0
  attached partial capable: 0
  attached inside ZPSDS persistent: 0
  attached requested inside ZPSDS: 0
  attached break_reply capable: 0
  attached pwr_dis capable: 0
  programmed minimum physical link rate: 1.5 Gbps
  hardware minimum physical link rate: 1.5 Gbps
  programmed maximum physical link rate: 6 Gbps
  hardware maximum physical link rate: 6 Gbps
  phy change count: 49
  virtual phy: 0
  partial pathway timeout value: 7 us
  routing attribute: table
  connector type: SAS Drive backplane receptacle (SFF-8482) [max 2 phys]
  connector element index: 0
  connector physical link: 0
  phy power condition: 0
  sas power capable: 0
  sas slumber capable: 0
  sas partial capable: 0
  sata slumber capable: 0
  sata partial capable: 0
  pwr_dis signal: 0
  pwr_dis control capable: 0
  sas slumber enabled: 0
  sas partial enabled: 0
  sata slumber enabled: 0
  sata partial enabled: 0
  attached device name: 0x0
  requested inside ZPSDS changed by expander: 0
  inside ZPSDS persistent: 0
  requested inside ZPSDS: 0
  zone group persistent: 1
  inside ZPSDS: 0
  zoning enabled: 0
  zone group: 1
  self-configuration status: 0
  self-configuration levels completed: 0
  self-configuration sas address: 0x0
  programmed phy capabilities: 0x0
  current phy capabilities: 0x0
  attached phy capabilities: 0x0
  reason: unknown
  negotiated physical link rate: phy enabled, 6 Gbps
  optical mode enabled: 0
  negotiated SSC: 0
  hardware muxing supported: 0
  default inside ZPSDS persistent: 0
  default requested inside ZPSDS: 0
  default zone group persistent: 1
  default zoning enabled: 0
  default zone group: 1
  saved inside ZPSDS persistent: 0
  saved requested inside ZPSDS: 0
  saved zone group persistent: 1
  saved zoning enabled: 0
  saved zone group: 1
  shadow inside ZPSDS persistent: 0
  shadow requested inside ZPSDS: 0
  shadow zone group persistent: 1
  shadow zoning enabled: 0
  shadow zone group: 1
  device slot number: 255
  device slot group number: 255
  device slot group output connector:      =20
Discover response:
  expander change count: 1328
  phy identifier: 13
  attached device type: SAS or SATA device
  attached reason: unknown
  negotiated logical link rate: phy enabled, 6 Gbps
  attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0
  attached sata port selector: 0
  STP buffer too small: 0
  attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D1
  SAS address: 0x50030480017ae23f
  attached SAS address: 0x50030480017ae20d
  attached phy identifier: 0
  attached persistent capable: 0
  attached power capable: 0
  attached slumber capable: 0
  attached partial capable: 0
  attached inside ZPSDS persistent: 0
  attached requested inside ZPSDS: 0
  attached break_reply capable: 0
  attached pwr_dis capable: 0
  programmed minimum physical link rate: 1.5 Gbps
  hardware minimum physical link rate: 1.5 Gbps
  programmed maximum physical link rate: 6 Gbps
  hardware maximum physical link rate: 6 Gbps
  phy change count: 49
  virtual phy: 0
  partial pathway timeout value: 7 us
  routing attribute: table
  connector type: SAS Drive backplane receptacle (SFF-8482) [max 2 phys]
  connector element index: 1
  connector physical link: 0
  phy power condition: 0
  sas power capable: 0
  sas slumber capable: 0
  sas partial capable: 0
  sata slumber capable: 0
  sata partial capable: 0
  pwr_dis signal: 0
  pwr_dis control capable: 0
  sas slumber enabled: 0
  sas partial enabled: 0
  sata slumber enabled: 0
  sata partial enabled: 0
  attached device name: 0x0
  requested inside ZPSDS changed by expander: 0
  inside ZPSDS persistent: 0
  requested inside ZPSDS: 0
  zone group persistent: 1
  inside ZPSDS: 0
  zoning enabled: 0
  zone group: 1
  self-configuration status: 0
  self-configuration levels completed: 0
  self-configuration sas address: 0x0
  programmed phy capabilities: 0x0
  current phy capabilities: 0x0
  attached phy capabilities: 0x0
  reason: unknown
  negotiated physical link rate: phy enabled, 6 Gbps
  optical mode enabled: 0
  negotiated SSC: 0
  hardware muxing supported: 0
  default inside ZPSDS persistent: 0
  default requested inside ZPSDS: 0
  default zone group persistent: 1
  default zoning enabled: 0
  default zone group: 1
  saved inside ZPSDS persistent: 0
  saved requested inside ZPSDS: 0
  saved zone group persistent: 1
  saved zoning enabled: 0
  saved zone group: 1
  shadow inside ZPSDS persistent: 0
  shadow requested inside ZPSDS: 0
  shadow zone group persistent: 1
  shadow zoning enabled: 0
  shadow zone group: 1
  device slot number: 255
  device slot group number: 255
  device slot group output connector:      =20
Discover response:
  expander change count: 1328
  phy identifier: 14
  attached device type: SAS or SATA device
  attached reason: unknown
  negotiated logical link rate: phy enabled, 6 Gbps
  attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0
  attached sata port selector: 0
  STP buffer too small: 0
  attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D1
  SAS address: 0x50030480017ae23f
  attached SAS address: 0x50030480017ae20e
  attached phy identifier: 0
  attached persistent capable: 0
  attached power capable: 0
  attached slumber capable: 0
  attached partial capable: 0
  attached inside ZPSDS persistent: 0
  attached requested inside ZPSDS: 0
  attached break_reply capable: 0
  attached pwr_dis capable: 0
  programmed minimum physical link rate: 1.5 Gbps
  hardware minimum physical link rate: 1.5 Gbps
  programmed maximum physical link rate: 6 Gbps
  hardware maximum physical link rate: 6 Gbps
  phy change count: 49
  virtual phy: 0
  partial pathway timeout value: 7 us
  routing attribute: table
  connector type: SAS Drive backplane receptacle (SFF-8482) [max 2 phys]
  connector element index: 2
  connector physical link: 0
  phy power condition: 0
  sas power capable: 0
  sas slumber capable: 0
  sas partial capable: 0
  sata slumber capable: 0
  sata partial capable: 0
  pwr_dis signal: 0
  pwr_dis control capable: 0
  sas slumber enabled: 0
  sas partial enabled: 0
  sata slumber enabled: 0
  sata partial enabled: 0
  attached device name: 0x0
  requested inside ZPSDS changed by expander: 0
  inside ZPSDS persistent: 0
  requested inside ZPSDS: 0
  zone group persistent: 1
  inside ZPSDS: 0
  zoning enabled: 0
  zone group: 1
  self-configuration status: 0
  self-configuration levels completed: 0
  self-configuration sas address: 0x0
  programmed phy capabilities: 0x0
  current phy capabilities: 0x0
  attached phy capabilities: 0x0
  reason: unknown
  negotiated physical link rate: phy enabled, 6 Gbps
  optical mode enabled: 0
  negotiated SSC: 0
  hardware muxing supported: 0
  default inside ZPSDS persistent: 0
  default requested inside ZPSDS: 0
  default zone group persistent: 1
  default zoning enabled: 0
  default zone group: 1
  saved inside ZPSDS persistent: 0
  saved requested inside ZPSDS: 0
  saved zone group persistent: 1
  saved zoning enabled: 0
  saved zone group: 1
  shadow inside ZPSDS persistent: 0
  shadow requested inside ZPSDS: 0
  shadow zone group persistent: 1
  shadow zoning enabled: 0
  shadow zone group: 1
  device slot number: 255
  device slot group number: 255
  device slot group output connector:      =20
Discover response:
  expander change count: 1328
  phy identifier: 15
  attached device type: SAS or SATA device
  attached reason: unknown
  negotiated logical link rate: phy enabled, 6 Gbps
  attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0
  attached sata port selector: 0
  STP buffer too small: 0
  attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D1
  SAS address: 0x50030480017ae23f
  attached SAS address: 0x50030480017ae20f
  attached phy identifier: 0
  attached persistent capable: 0
  attached power capable: 0
  attached slumber capable: 0
  attached partial capable: 0
  attached inside ZPSDS persistent: 0
  attached requested inside ZPSDS: 0
  attached break_reply capable: 0
  attached pwr_dis capable: 0
  programmed minimum physical link rate: 1.5 Gbps
  hardware minimum physical link rate: 1.5 Gbps
  programmed maximum physical link rate: 6 Gbps
  hardware maximum physical link rate: 6 Gbps
  phy change count: 49
  virtual phy: 0
  partial pathway timeout value: 7 us
  routing attribute: table
  connector type: SAS Drive backplane receptacle (SFF-8482) [max 2 phys]
  connector element index: 3
  connector physical link: 0
  phy power condition: 0
  sas power capable: 0
  sas slumber capable: 0
  sas partial capable: 0
  sata slumber capable: 0
  sata partial capable: 0
  pwr_dis signal: 0
  pwr_dis control capable: 0
  sas slumber enabled: 0
  sas partial enabled: 0
  sata slumber enabled: 0
  sata partial enabled: 0
  attached device name: 0x0
  requested inside ZPSDS changed by expander: 0
  inside ZPSDS persistent: 0
  requested inside ZPSDS: 0
  zone group persistent: 1
  inside ZPSDS: 0
  zoning enabled: 0
  zone group: 1
  self-configuration status: 0
  self-configuration levels completed: 0
  self-configuration sas address: 0x0
  programmed phy capabilities: 0x0
  current phy capabilities: 0x0
  attached phy capabilities: 0x0
  reason: unknown
  negotiated physical link rate: phy enabled, 6 Gbps
  optical mode enabled: 0
  negotiated SSC: 0
  hardware muxing supported: 0
  default inside ZPSDS persistent: 0
  default requested inside ZPSDS: 0
  default zone group persistent: 1
  default zoning enabled: 0
  default zone group: 1
  saved inside ZPSDS persistent: 0
  saved requested inside ZPSDS: 0
  saved zone group persistent: 1
  saved zoning enabled: 0
  saved zone group: 1
  shadow inside ZPSDS persistent: 0
  shadow requested inside ZPSDS: 0
  shadow zone group persistent: 1
  shadow zoning enabled: 0
  shadow zone group: 1
  device slot number: 255
  device slot group number: 255
  device slot group output connector:      =20
Discover response:
  expander change count: 1328
  phy identifier: 16
  attached device type: SAS or SATA device
  attached reason: unknown
  negotiated logical link rate: phy enabled, 6 Gbps
  attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0
  attached sata port selector: 0
  STP buffer too small: 0
  attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D1
  SAS address: 0x50030480017ae23f
  attached SAS address: 0x50030480017ae210
  attached phy identifier: 0
  attached persistent capable: 0
  attached power capable: 0
  attached slumber capable: 0
  attached partial capable: 0
  attached inside ZPSDS persistent: 0
  attached requested inside ZPSDS: 0
  attached break_reply capable: 0
  attached pwr_dis capable: 0
  programmed minimum physical link rate: 1.5 Gbps
  hardware minimum physical link rate: 1.5 Gbps
  programmed maximum physical link rate: 6 Gbps
  hardware maximum physical link rate: 6 Gbps
  phy change count: 49
  virtual phy: 0
  partial pathway timeout value: 7 us
  routing attribute: table
  connector type: SAS Drive backplane receptacle (SFF-8482) [max 2 phys]
  connector element index: 4
  connector physical link: 0
  phy power condition: 0
  sas power capable: 0
  sas slumber capable: 0
  sas partial capable: 0
  sata slumber capable: 0
  sata partial capable: 0
  pwr_dis signal: 0
  pwr_dis control capable: 0
  sas slumber enabled: 0
  sas partial enabled: 0
  sata slumber enabled: 0
  sata partial enabled: 0
  attached device name: 0x0
  requested inside ZPSDS changed by expander: 0
  inside ZPSDS persistent: 0
  requested inside ZPSDS: 0
  zone group persistent: 1
  inside ZPSDS: 0
  zoning enabled: 0
  zone group: 1
  self-configuration status: 0
  self-configuration levels completed: 0
  self-configuration sas address: 0x0
  programmed phy capabilities: 0x0
  current phy capabilities: 0x0
  attached phy capabilities: 0x0
  reason: unknown
  negotiated physical link rate: phy enabled, 6 Gbps
  optical mode enabled: 0
  negotiated SSC: 0
  hardware muxing supported: 0
  default inside ZPSDS persistent: 0
  default requested inside ZPSDS: 0
  default zone group persistent: 1
  default zoning enabled: 0
  default zone group: 1
  saved inside ZPSDS persistent: 0
  saved requested inside ZPSDS: 0
  saved zone group persistent: 1
  saved zoning enabled: 0
  saved zone group: 1
  shadow inside ZPSDS persistent: 0
  shadow requested inside ZPSDS: 0
  shadow zone group persistent: 1
  shadow zoning enabled: 0
  shadow zone group: 1
  device slot number: 255
  device slot group number: 255
  device slot group output connector:      =20
Discover response:
  expander change count: 1328
  phy identifier: 17
  attached device type: SAS or SATA device
  attached reason: unknown
  negotiated logical link rate: phy enabled, 6 Gbps
  attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0
  attached sata port selector: 0
  STP buffer too small: 0
  attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D1
  SAS address: 0x50030480017ae23f
  attached SAS address: 0x50030480017ae211
  attached phy identifier: 0
  attached persistent capable: 0
  attached power capable: 0
  attached slumber capable: 0
  attached partial capable: 0
  attached inside ZPSDS persistent: 0
  attached requested inside ZPSDS: 0
  attached break_reply capable: 0
  attached pwr_dis capable: 0
  programmed minimum physical link rate: 1.5 Gbps
  hardware minimum physical link rate: 1.5 Gbps
  programmed maximum physical link rate: 6 Gbps
  hardware maximum physical link rate: 6 Gbps
  phy change count: 48
  virtual phy: 0
  partial pathway timeout value: 7 us
  routing attribute: table
  connector type: SAS Drive backplane receptacle (SFF-8482) [max 2 phys]
  connector element index: 5
  connector physical link: 0
  phy power condition: 0
  sas power capable: 0
  sas slumber capable: 0
  sas partial capable: 0
  sata slumber capable: 0
  sata partial capable: 0
  pwr_dis signal: 0
  pwr_dis control capable: 0
  sas slumber enabled: 0
  sas partial enabled: 0
  sata slumber enabled: 0
  sata partial enabled: 0
  attached device name: 0x0
  requested inside ZPSDS changed by expander: 0
  inside ZPSDS persistent: 0
  requested inside ZPSDS: 0
  zone group persistent: 1
  inside ZPSDS: 0
  zoning enabled: 0
  zone group: 1
  self-configuration status: 0
  self-configuration levels completed: 0
  self-configuration sas address: 0x0
  programmed phy capabilities: 0x0
  current phy capabilities: 0x0
  attached phy capabilities: 0x0
  reason: unknown
  negotiated physical link rate: phy enabled, 6 Gbps
  optical mode enabled: 0
  negotiated SSC: 0
  hardware muxing supported: 0
  default inside ZPSDS persistent: 0
  default requested inside ZPSDS: 0
  default zone group persistent: 1
  default zoning enabled: 0
  default zone group: 1
  saved inside ZPSDS persistent: 0
  saved requested inside ZPSDS: 0
  saved zone group persistent: 1
  saved zoning enabled: 0
  saved zone group: 1
  shadow inside ZPSDS persistent: 0
  shadow requested inside ZPSDS: 0
  shadow zone group persistent: 1
  shadow zoning enabled: 0
  shadow zone group: 1
  device slot number: 255
  device slot group number: 255
  device slot group output connector:      =20
Discover response:
  expander change count: 1328
  phy identifier: 18
  attached device type: SAS or SATA device
  attached reason: unknown
  negotiated logical link rate: phy enabled, 6 Gbps
  attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0
  attached sata port selector: 0
  STP buffer too small: 0
  attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D1
  SAS address: 0x50030480017ae23f
  attached SAS address: 0x50030480017ae212
  attached phy identifier: 0
  attached persistent capable: 0
  attached power capable: 0
  attached slumber capable: 0
  attached partial capable: 0
  attached inside ZPSDS persistent: 0
  attached requested inside ZPSDS: 0
  attached break_reply capable: 0
  attached pwr_dis capable: 0
  programmed minimum physical link rate: 1.5 Gbps
  hardware minimum physical link rate: 1.5 Gbps
  programmed maximum physical link rate: 6 Gbps
  hardware maximum physical link rate: 6 Gbps
  phy change count: 48
  virtual phy: 0
  partial pathway timeout value: 7 us
  routing attribute: table
  connector type: SAS Drive backplane receptacle (SFF-8482) [max 2 phys]
  connector element index: 6
  connector physical link: 0
  phy power condition: 0
  sas power capable: 0
  sas slumber capable: 0
  sas partial capable: 0
  sata slumber capable: 0
  sata partial capable: 0
  pwr_dis signal: 0
  pwr_dis control capable: 0
  sas slumber enabled: 0
  sas partial enabled: 0
  sata slumber enabled: 0
  sata partial enabled: 0
  attached device name: 0x0
  requested inside ZPSDS changed by expander: 0
  inside ZPSDS persistent: 0
  requested inside ZPSDS: 0
  zone group persistent: 1
  inside ZPSDS: 0
  zoning enabled: 0
  zone group: 1
  self-configuration status: 0
  self-configuration levels completed: 0
  self-configuration sas address: 0x0
  programmed phy capabilities: 0x0
  current phy capabilities: 0x0
  attached phy capabilities: 0x0
  reason: unknown
  negotiated physical link rate: phy enabled, 6 Gbps
  optical mode enabled: 0
  negotiated SSC: 0
  hardware muxing supported: 0
  default inside ZPSDS persistent: 0
  default requested inside ZPSDS: 0
  default zone group persistent: 1
  default zoning enabled: 0
  default zone group: 1
  saved inside ZPSDS persistent: 0
  saved requested inside ZPSDS: 0
  saved zone group persistent: 1
  saved zoning enabled: 0
  saved zone group: 1
  shadow inside ZPSDS persistent: 0
  shadow requested inside ZPSDS: 0
  shadow zone group persistent: 1
  shadow zoning enabled: 0
  shadow zone group: 1
  device slot number: 255
  device slot group number: 255
  device slot group output connector:      =20
Discover response:
  expander change count: 1328
  phy identifier: 19
  attached device type: SAS or SATA device
  attached reason: unknown
  negotiated logical link rate: phy enabled, 6 Gbps
  attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0
  attached sata port selector: 0
  STP buffer too small: 0
  attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D1
  SAS address: 0x50030480017ae23f
  attached SAS address: 0x50030480017ae213
  attached phy identifier: 0
  attached persistent capable: 0
  attached power capable: 0
  attached slumber capable: 0
  attached partial capable: 0
  attached inside ZPSDS persistent: 0
  attached requested inside ZPSDS: 0
  attached break_reply capable: 0
  attached pwr_dis capable: 0
  programmed minimum physical link rate: 1.5 Gbps
  hardware minimum physical link rate: 1.5 Gbps
  programmed maximum physical link rate: 6 Gbps
  hardware maximum physical link rate: 6 Gbps
  phy change count: 49
  virtual phy: 0
  partial pathway timeout value: 7 us
  routing attribute: table
  connector type: SAS Drive backplane receptacle (SFF-8482) [max 2 phys]
  connector element index: 7
  connector physical link: 0
  phy power condition: 0
  sas power capable: 0
  sas slumber capable: 0
  sas partial capable: 0
  sata slumber capable: 0
  sata partial capable: 0
  pwr_dis signal: 0
  pwr_dis control capable: 0
  sas slumber enabled: 0
  sas partial enabled: 0
  sata slumber enabled: 0
  sata partial enabled: 0
  attached device name: 0x0
  requested inside ZPSDS changed by expander: 0
  inside ZPSDS persistent: 0
  requested inside ZPSDS: 0
  zone group persistent: 1
  inside ZPSDS: 0
  zoning enabled: 0
  zone group: 1
  self-configuration status: 0
  self-configuration levels completed: 0
  self-configuration sas address: 0x0
  programmed phy capabilities: 0x0
  current phy capabilities: 0x0
  attached phy capabilities: 0x0
  reason: unknown
  negotiated physical link rate: phy enabled, 6 Gbps
  optical mode enabled: 0
  negotiated SSC: 0
  hardware muxing supported: 0
  default inside ZPSDS persistent: 0
  default requested inside ZPSDS: 0
  default zone group persistent: 1
  default zoning enabled: 0
  default zone group: 1
  saved inside ZPSDS persistent: 0
  saved requested inside ZPSDS: 0
  saved zone group persistent: 1
  saved zoning enabled: 0
  saved zone group: 1
  shadow inside ZPSDS persistent: 0
  shadow requested inside ZPSDS: 0
  shadow zone group persistent: 1
  shadow zoning enabled: 0
  shadow zone group: 1
  device slot number: 255
  device slot group number: 255
  device slot group output connector:      =20
Discover response:
  expander change count: 1328
  phy identifier: 20
  attached device type: SAS or SATA device
  attached reason: unknown
  negotiated logical link rate: phy enabled, 6 Gbps
  attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0
  attached sata port selector: 0
  STP buffer too small: 0
  attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D1
  SAS address: 0x50030480017ae23f
  attached SAS address: 0x50030480017ae214
  attached phy identifier: 0
  attached persistent capable: 0
  attached power capable: 0
  attached slumber capable: 0
  attached partial capable: 0
  attached inside ZPSDS persistent: 0
  attached requested inside ZPSDS: 0
  attached break_reply capable: 0
  attached pwr_dis capable: 0
  programmed minimum physical link rate: 1.5 Gbps
  hardware minimum physical link rate: 1.5 Gbps
  programmed maximum physical link rate: 6 Gbps
  hardware maximum physical link rate: 6 Gbps
  phy change count: 48
  virtual phy: 0
  partial pathway timeout value: 7 us
  routing attribute: table
  connector type: SAS Drive backplane receptacle (SFF-8482) [max 2 phys]
  connector element index: 8
  connector physical link: 0
  phy power condition: 0
  sas power capable: 0
  sas slumber capable: 0
  sas partial capable: 0
  sata slumber capable: 0
  sata partial capable: 0
  pwr_dis signal: 0
  pwr_dis control capable: 0
  sas slumber enabled: 0
  sas partial enabled: 0
  sata slumber enabled: 0
  sata partial enabled: 0
  attached device name: 0x0
  requested inside ZPSDS changed by expander: 0
  inside ZPSDS persistent: 0
  requested inside ZPSDS: 0
  zone group persistent: 1
  inside ZPSDS: 0
  zoning enabled: 0
  zone group: 1
  self-configuration status: 0
  self-configuration levels completed: 0
  self-configuration sas address: 0x0
  programmed phy capabilities: 0x0
  current phy capabilities: 0x0
  attached phy capabilities: 0x0
  reason: unknown
  negotiated physical link rate: phy enabled, 6 Gbps
  optical mode enabled: 0
  negotiated SSC: 0
  hardware muxing supported: 0
  default inside ZPSDS persistent: 0
  default requested inside ZPSDS: 0
  default zone group persistent: 1
  default zoning enabled: 0
  default zone group: 1
  saved inside ZPSDS persistent: 0
  saved requested inside ZPSDS: 0
  saved zone group persistent: 1
  saved zoning enabled: 0
  saved zone group: 1
  shadow inside ZPSDS persistent: 0
  shadow requested inside ZPSDS: 0
  shadow zone group persistent: 1
  shadow zoning enabled: 0
  shadow zone group: 1
  device slot number: 255
  device slot group number: 255
  device slot group output connector:      =20
Discover response:
  expander change count: 1328
  phy identifier: 21
  attached device type: SAS or SATA device
  attached reason: unknown
  negotiated logical link rate: phy enabled, 6 Gbps
  attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0
  attached sata port selector: 0
  STP buffer too small: 0
  attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D1
  SAS address: 0x50030480017ae23f
  attached SAS address: 0x50030480017ae215
  attached phy identifier: 0
  attached persistent capable: 0
  attached power capable: 0
  attached slumber capable: 0
  attached partial capable: 0
  attached inside ZPSDS persistent: 0
  attached requested inside ZPSDS: 0
  attached break_reply capable: 0
  attached pwr_dis capable: 0
  programmed minimum physical link rate: 1.5 Gbps
  hardware minimum physical link rate: 1.5 Gbps
  programmed maximum physical link rate: 6 Gbps
  hardware maximum physical link rate: 6 Gbps
  phy change count: 48
  virtual phy: 0
  partial pathway timeout value: 7 us
  routing attribute: table
  connector type: SAS Drive backplane receptacle (SFF-8482) [max 2 phys]
  connector element index: 9
  connector physical link: 0
  phy power condition: 0
  sas power capable: 0
  sas slumber capable: 0
  sas partial capable: 0
  sata slumber capable: 0
  sata partial capable: 0
  pwr_dis signal: 0
  pwr_dis control capable: 0
  sas slumber enabled: 0
  sas partial enabled: 0
  sata slumber enabled: 0
  sata partial enabled: 0
  attached device name: 0x0
  requested inside ZPSDS changed by expander: 0
  inside ZPSDS persistent: 0
  requested inside ZPSDS: 0
  zone group persistent: 1
  inside ZPSDS: 0
  zoning enabled: 0
  zone group: 1
  self-configuration status: 0
  self-configuration levels completed: 0
  self-configuration sas address: 0x0
  programmed phy capabilities: 0x0
  current phy capabilities: 0x0
  attached phy capabilities: 0x0
  reason: unknown
  negotiated physical link rate: phy enabled, 6 Gbps
  optical mode enabled: 0
  negotiated SSC: 0
  hardware muxing supported: 0
  default inside ZPSDS persistent: 0
  default requested inside ZPSDS: 0
  default zone group persistent: 1
  default zoning enabled: 0
  default zone group: 1
  saved inside ZPSDS persistent: 0
  saved requested inside ZPSDS: 0
  saved zone group persistent: 1
  saved zoning enabled: 0
  saved zone group: 1
  shadow inside ZPSDS persistent: 0
  shadow requested inside ZPSDS: 0
  shadow zone group persistent: 1
  shadow zoning enabled: 0
  shadow zone group: 1
  device slot number: 255
  device slot group number: 255
  device slot group output connector:      =20
Discover response:
  expander change count: 1328
  phy identifier: 22
  attached device type: SAS or SATA device
  attached reason: unknown
  negotiated logical link rate: phy enabled, 6 Gbps
  attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0
  attached sata port selector: 0
  STP buffer too small: 0
  attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D1
  SAS address: 0x50030480017ae23f
  attached SAS address: 0x50030480017ae216
  attached phy identifier: 0
  attached persistent capable: 0
  attached power capable: 0
  attached slumber capable: 0
  attached partial capable: 0
  attached inside ZPSDS persistent: 0
  attached requested inside ZPSDS: 0
  attached break_reply capable: 0
  attached pwr_dis capable: 0
  programmed minimum physical link rate: 1.5 Gbps
  hardware minimum physical link rate: 1.5 Gbps
  programmed maximum physical link rate: 6 Gbps
  hardware maximum physical link rate: 6 Gbps
  phy change count: 48
  virtual phy: 0
  partial pathway timeout value: 7 us
  routing attribute: table
  connector type: SAS Drive backplane receptacle (SFF-8482) [max 2 phys]
  connector element index: 10
  connector physical link: 0
  phy power condition: 0
  sas power capable: 0
  sas slumber capable: 0
  sas partial capable: 0
  sata slumber capable: 0
  sata partial capable: 0
  pwr_dis signal: 0
  pwr_dis control capable: 0
  sas slumber enabled: 0
  sas partial enabled: 0
  sata slumber enabled: 0
  sata partial enabled: 0
  attached device name: 0x0
  requested inside ZPSDS changed by expander: 0
  inside ZPSDS persistent: 0
  requested inside ZPSDS: 0
  zone group persistent: 1
  inside ZPSDS: 0
  zoning enabled: 0
  zone group: 1
  self-configuration status: 0
  self-configuration levels completed: 0
  self-configuration sas address: 0x0
  programmed phy capabilities: 0x0
  current phy capabilities: 0x0
  attached phy capabilities: 0x0
  reason: unknown
  negotiated physical link rate: phy enabled, 6 Gbps
  optical mode enabled: 0
  negotiated SSC: 0
  hardware muxing supported: 0
  default inside ZPSDS persistent: 0
  default requested inside ZPSDS: 0
  default zone group persistent: 1
  default zoning enabled: 0
  default zone group: 1
  saved inside ZPSDS persistent: 0
  saved requested inside ZPSDS: 0
  saved zone group persistent: 1
  saved zoning enabled: 0
  saved zone group: 1
  shadow inside ZPSDS persistent: 0
  shadow requested inside ZPSDS: 0
  shadow zone group persistent: 1
  shadow zoning enabled: 0
  shadow zone group: 1
  device slot number: 255
  device slot group number: 255
  device slot group output connector:      =20
Discover response:
  expander change count: 1328
  phy identifier: 23
  attached device type: SAS or SATA device
  attached reason: unknown
  negotiated logical link rate: phy enabled, 6 Gbps
  attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0
  attached sata port selector: 0
  STP buffer too small: 0
  attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D1
  SAS address: 0x50030480017ae23f
  attached SAS address: 0x50030480017ae217
  attached phy identifier: 0
  attached persistent capable: 0
  attached power capable: 0
  attached slumber capable: 0
  attached partial capable: 0
  attached inside ZPSDS persistent: 0
  attached requested inside ZPSDS: 0
  attached break_reply capable: 0
  attached pwr_dis capable: 0
  programmed minimum physical link rate: 1.5 Gbps
  hardware minimum physical link rate: 1.5 Gbps
  programmed maximum physical link rate: 6 Gbps
  hardware maximum physical link rate: 6 Gbps
  phy change count: 49
  virtual phy: 0
  partial pathway timeout value: 7 us
  routing attribute: table
  connector type: SAS Drive backplane receptacle (SFF-8482) [max 2 phys]
  connector element index: 11
  connector physical link: 0
  phy power condition: 0
  sas power capable: 0
  sas slumber capable: 0
  sas partial capable: 0
  sata slumber capable: 0
  sata partial capable: 0
  pwr_dis signal: 0
  pwr_dis control capable: 0
  sas slumber enabled: 0
  sas partial enabled: 0
  sata slumber enabled: 0
  sata partial enabled: 0
  attached device name: 0x0
  requested inside ZPSDS changed by expander: 0
  inside ZPSDS persistent: 0
  requested inside ZPSDS: 0
  zone group persistent: 1
  inside ZPSDS: 0
  zoning enabled: 0
  zone group: 1
  self-configuration status: 0
  self-configuration levels completed: 0
  self-configuration sas address: 0x0
  programmed phy capabilities: 0x0
  current phy capabilities: 0x0
  attached phy capabilities: 0x0
  reason: unknown
  negotiated physical link rate: phy enabled, 6 Gbps
  optical mode enabled: 0
  negotiated SSC: 0
  hardware muxing supported: 0
  default inside ZPSDS persistent: 0
  default requested inside ZPSDS: 0
  default zone group persistent: 1
  default zoning enabled: 0
  default zone group: 1
  saved inside ZPSDS persistent: 0
  saved requested inside ZPSDS: 0
  saved zone group persistent: 1
  saved zoning enabled: 0
  saved zone group: 1
  shadow inside ZPSDS persistent: 0
  shadow requested inside ZPSDS: 0
  shadow zone group persistent: 1
  shadow zoning enabled: 0
  shadow zone group: 1
  device slot number: 255
  device slot group number: 255
  device slot group output connector:      =20
Discover response:
  expander change count: 1328
  phy identifier: 24
  attached device type: SAS or SATA device
  attached reason: unknown
  negotiated logical link rate: phy enabled, 6 Gbps
  attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0
  attached sata port selector: 0
  STP buffer too small: 0
  attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D1
  SAS address: 0x50030480017ae23f
  attached SAS address: 0x50030480017ae218
  attached phy identifier: 0
  attached persistent capable: 0
  attached power capable: 0
  attached slumber capable: 0
  attached partial capable: 0
  attached inside ZPSDS persistent: 0
  attached requested inside ZPSDS: 0
  attached break_reply capable: 0
  attached pwr_dis capable: 0
  programmed minimum physical link rate: 1.5 Gbps
  hardware minimum physical link rate: 1.5 Gbps
  programmed maximum physical link rate: 6 Gbps
  hardware maximum physical link rate: 6 Gbps
  phy change count: 48
  virtual phy: 0
  partial pathway timeout value: 7 us
  routing attribute: table
  connector type: SAS Drive backplane receptacle (SFF-8482) [max 2 phys]
  connector element index: 12
  connector physical link: 0
  phy power condition: 0
  sas power capable: 0
  sas slumber capable: 0
  sas partial capable: 0
  sata slumber capable: 0
  sata partial capable: 0
  pwr_dis signal: 0
  pwr_dis control capable: 0
  sas slumber enabled: 0
  sas partial enabled: 0
  sata slumber enabled: 0
  sata partial enabled: 0
  attached device name: 0x0
  requested inside ZPSDS changed by expander: 0
  inside ZPSDS persistent: 0
  requested inside ZPSDS: 0
  zone group persistent: 1
  inside ZPSDS: 0
  zoning enabled: 0
  zone group: 1
  self-configuration status: 0
  self-configuration levels completed: 0
  self-configuration sas address: 0x0
  programmed phy capabilities: 0x0
  current phy capabilities: 0x0
  attached phy capabilities: 0x0
  reason: unknown
  negotiated physical link rate: phy enabled, 6 Gbps
  optical mode enabled: 0
  negotiated SSC: 0
  hardware muxing supported: 0
  default inside ZPSDS persistent: 0
  default requested inside ZPSDS: 0
  default zone group persistent: 1
  default zoning enabled: 0
  default zone group: 1
  saved inside ZPSDS persistent: 0
  saved requested inside ZPSDS: 0
  saved zone group persistent: 1
  saved zoning enabled: 0
  saved zone group: 1
  shadow inside ZPSDS persistent: 0
  shadow requested inside ZPSDS: 0
  shadow zone group persistent: 1
  shadow zoning enabled: 0
  shadow zone group: 1
  device slot number: 255
  device slot group number: 255
  device slot group output connector:      =20
Discover response:
  expander change count: 1328
  phy identifier: 25
  attached device type: SAS or SATA device
  attached reason: unknown
  negotiated logical link rate: phy enabled, 6 Gbps
  attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0
  attached sata port selector: 0
  STP buffer too small: 0
  attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D1
  SAS address: 0x50030480017ae23f
  attached SAS address: 0x50030480017ae219
  attached phy identifier: 0
  attached persistent capable: 0
  attached power capable: 0
  attached slumber capable: 0
  attached partial capable: 0
  attached inside ZPSDS persistent: 0
  attached requested inside ZPSDS: 0
  attached break_reply capable: 0
  attached pwr_dis capable: 0
  programmed minimum physical link rate: 1.5 Gbps
  hardware minimum physical link rate: 1.5 Gbps
  programmed maximum physical link rate: 6 Gbps
  hardware maximum physical link rate: 6 Gbps
  phy change count: 48
  virtual phy: 0
  partial pathway timeout value: 7 us
  routing attribute: table
  connector type: SAS Drive backplane receptacle (SFF-8482) [max 2 phys]
  connector element index: 13
  connector physical link: 0
  phy power condition: 0
  sas power capable: 0
  sas slumber capable: 0
  sas partial capable: 0
  sata slumber capable: 0
  sata partial capable: 0
  pwr_dis signal: 0
  pwr_dis control capable: 0
  sas slumber enabled: 0
  sas partial enabled: 0
  sata slumber enabled: 0
  sata partial enabled: 0
  attached device name: 0x0
  requested inside ZPSDS changed by expander: 0
  inside ZPSDS persistent: 0
  requested inside ZPSDS: 0
  zone group persistent: 1
  inside ZPSDS: 0
  zoning enabled: 0
  zone group: 1
  self-configuration status: 0
  self-configuration levels completed: 0
  self-configuration sas address: 0x0
  programmed phy capabilities: 0x0
  current phy capabilities: 0x0
  attached phy capabilities: 0x0
  reason: unknown
  negotiated physical link rate: phy enabled, 6 Gbps
  optical mode enabled: 0
  negotiated SSC: 0
  hardware muxing supported: 0
  default inside ZPSDS persistent: 0
  default requested inside ZPSDS: 0
  default zone group persistent: 1
  default zoning enabled: 0
  default zone group: 1
  saved inside ZPSDS persistent: 0
  saved requested inside ZPSDS: 0
  saved zone group persistent: 1
  saved zoning enabled: 0
  saved zone group: 1
  shadow inside ZPSDS persistent: 0
  shadow requested inside ZPSDS: 0
  shadow zone group persistent: 1
  shadow zoning enabled: 0
  shadow zone group: 1
  device slot number: 255
  device slot group number: 255
  device slot group output connector:      =20
Discover response:
  expander change count: 1328
  phy identifier: 26
  attached device type: SAS or SATA device
  attached reason: unknown
  negotiated logical link rate: phy enabled, 6 Gbps
  attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0
  attached sata port selector: 0
  STP buffer too small: 0
  attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D1
  SAS address: 0x50030480017ae23f
  attached SAS address: 0x50030480017ae21a
  attached phy identifier: 0
  attached persistent capable: 0
  attached power capable: 0
  attached slumber capable: 0
  attached partial capable: 0
  attached inside ZPSDS persistent: 0
  attached requested inside ZPSDS: 0
  attached break_reply capable: 0
  attached pwr_dis capable: 0
  programmed minimum physical link rate: 1.5 Gbps
  hardware minimum physical link rate: 1.5 Gbps
  programmed maximum physical link rate: 6 Gbps
  hardware maximum physical link rate: 6 Gbps
  phy change count: 48
  virtual phy: 0
  partial pathway timeout value: 7 us
  routing attribute: table
  connector type: SAS Drive backplane receptacle (SFF-8482) [max 2 phys]
  connector element index: 14
  connector physical link: 0
  phy power condition: 0
  sas power capable: 0
  sas slumber capable: 0
  sas partial capable: 0
  sata slumber capable: 0
  sata partial capable: 0
  pwr_dis signal: 0
  pwr_dis control capable: 0
  sas slumber enabled: 0
  sas partial enabled: 0
  sata slumber enabled: 0
  sata partial enabled: 0
  attached device name: 0x0
  requested inside ZPSDS changed by expander: 0
  inside ZPSDS persistent: 0
  requested inside ZPSDS: 0
  zone group persistent: 1
  inside ZPSDS: 0
  zoning enabled: 0
  zone group: 1
  self-configuration status: 0
  self-configuration levels completed: 0
  self-configuration sas address: 0x0
  programmed phy capabilities: 0x0
  current phy capabilities: 0x0
  attached phy capabilities: 0x0
  reason: unknown
  negotiated physical link rate: phy enabled, 6 Gbps
  optical mode enabled: 0
  negotiated SSC: 0
  hardware muxing supported: 0
  default inside ZPSDS persistent: 0
  default requested inside ZPSDS: 0
  default zone group persistent: 1
  default zoning enabled: 0
  default zone group: 1
  saved inside ZPSDS persistent: 0
  saved requested inside ZPSDS: 0
  saved zone group persistent: 1
  saved zoning enabled: 0
  saved zone group: 1
  shadow inside ZPSDS persistent: 0
  shadow requested inside ZPSDS: 0
  shadow zone group persistent: 1
  shadow zoning enabled: 0
  shadow zone group: 1
  device slot number: 255
  device slot group number: 255
  device slot group output connector:      =20
Discover response:
  expander change count: 1328
  phy identifier: 27
  attached device type: SAS or SATA device
  attached reason: unknown
  negotiated logical link rate: phy enabled, 6 Gbps
  attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0
  attached sata port selector: 0
  STP buffer too small: 0
  attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D1
  SAS address: 0x50030480017ae23f
  attached SAS address: 0x50030480017ae21b
  attached phy identifier: 0
  attached persistent capable: 0
  attached power capable: 0
  attached slumber capable: 0
  attached partial capable: 0
  attached inside ZPSDS persistent: 0
  attached requested inside ZPSDS: 0
  attached break_reply capable: 0
  attached pwr_dis capable: 0
  programmed minimum physical link rate: 1.5 Gbps
  hardware minimum physical link rate: 1.5 Gbps
  programmed maximum physical link rate: 6 Gbps
  hardware maximum physical link rate: 6 Gbps
  phy change count: 49
  virtual phy: 0
  partial pathway timeout value: 7 us
  routing attribute: table
  connector type: SAS Drive backplane receptacle (SFF-8482) [max 2 phys]
  connector element index: 15
  connector physical link: 0
  phy power condition: 0
  sas power capable: 0
  sas slumber capable: 0
  sas partial capable: 0
  sata slumber capable: 0
  sata partial capable: 0
  pwr_dis signal: 0
  pwr_dis control capable: 0
  sas slumber enabled: 0
  sas partial enabled: 0
  sata slumber enabled: 0
  sata partial enabled: 0
  attached device name: 0x0
  requested inside ZPSDS changed by expander: 0
  inside ZPSDS persistent: 0
  requested inside ZPSDS: 0
  zone group persistent: 1
  inside ZPSDS: 0
  zoning enabled: 0
  zone group: 1
  self-configuration status: 0
  self-configuration levels completed: 0
  self-configuration sas address: 0x0
  programmed phy capabilities: 0x0
  current phy capabilities: 0x0
  attached phy capabilities: 0x0
  reason: unknown
  negotiated physical link rate: phy enabled, 6 Gbps
  optical mode enabled: 0
  negotiated SSC: 0
  hardware muxing supported: 0
  default inside ZPSDS persistent: 0
  default requested inside ZPSDS: 0
  default zone group persistent: 1
  default zoning enabled: 0
  default zone group: 1
  saved inside ZPSDS persistent: 0
  saved requested inside ZPSDS: 0
  saved zone group persistent: 1
  saved zoning enabled: 0
  saved zone group: 1
  shadow inside ZPSDS persistent: 0
  shadow requested inside ZPSDS: 0
  shadow zone group persistent: 1
  shadow zoning enabled: 0
  shadow zone group: 1
  device slot number: 255
  device slot group number: 255
  device slot group output connector:      =20
Discover response:
  expander change count: 1328
  phy identifier: 28
  attached device type: SAS or SATA device
  attached reason: unknown
  negotiated logical link rate: phy enabled, 6 Gbps
  attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0
  attached sata port selector: 0
  STP buffer too small: 0
  attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D1
  SAS address: 0x50030480017ae23f
  attached SAS address: 0x50030480017ae21c
  attached phy identifier: 0
  attached persistent capable: 0
  attached power capable: 0
  attached slumber capable: 0
  attached partial capable: 0
  attached inside ZPSDS persistent: 0
  attached requested inside ZPSDS: 0
  attached break_reply capable: 0
  attached pwr_dis capable: 0
  programmed minimum physical link rate: 1.5 Gbps
  hardware minimum physical link rate: 1.5 Gbps
  programmed maximum physical link rate: 6 Gbps
  hardware maximum physical link rate: 6 Gbps
  phy change count: 45
  virtual phy: 0
  partial pathway timeout value: 7 us
  routing attribute: table
  connector type: SAS Drive backplane receptacle (SFF-8482) [max 2 phys]
  connector element index: 16
  connector physical link: 0
  phy power condition: 0
  sas power capable: 0
  sas slumber capable: 0
  sas partial capable: 0
  sata slumber capable: 0
  sata partial capable: 0
  pwr_dis signal: 0
  pwr_dis control capable: 0
  sas slumber enabled: 0
  sas partial enabled: 0
  sata slumber enabled: 0
  sata partial enabled: 0
  attached device name: 0x0
  requested inside ZPSDS changed by expander: 0
  inside ZPSDS persistent: 0
  requested inside ZPSDS: 0
  zone group persistent: 1
  inside ZPSDS: 0
  zoning enabled: 0
  zone group: 1
  self-configuration status: 0
  self-configuration levels completed: 0
  self-configuration sas address: 0x0
  programmed phy capabilities: 0x0
  current phy capabilities: 0x0
  attached phy capabilities: 0x0
  reason: unknown
  negotiated physical link rate: phy enabled, 6 Gbps
  optical mode enabled: 0
  negotiated SSC: 0
  hardware muxing supported: 0
  default inside ZPSDS persistent: 0
  default requested inside ZPSDS: 0
  default zone group persistent: 1
  default zoning enabled: 0
  default zone group: 1
  saved inside ZPSDS persistent: 0
  saved requested inside ZPSDS: 0
  saved zone group persistent: 1
  saved zoning enabled: 0
  saved zone group: 1
  shadow inside ZPSDS persistent: 0
  shadow requested inside ZPSDS: 0
  shadow zone group persistent: 1
  shadow zoning enabled: 0
  shadow zone group: 1
  device slot number: 255
  device slot group number: 255
  device slot group output connector:      =20
Discover response:
  expander change count: 1328
  phy identifier: 29
  attached device type: SAS or SATA device
  attached reason: unknown
  negotiated logical link rate: phy enabled, 6 Gbps
  attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0
  attached sata port selector: 0
  STP buffer too small: 0
  attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D1
  SAS address: 0x50030480017ae23f
  attached SAS address: 0x50030480017ae21d
  attached phy identifier: 0
  attached persistent capable: 0
  attached power capable: 0
  attached slumber capable: 0
  attached partial capable: 0
  attached inside ZPSDS persistent: 0
  attached requested inside ZPSDS: 0
  attached break_reply capable: 0
  attached pwr_dis capable: 0
  programmed minimum physical link rate: 1.5 Gbps
  hardware minimum physical link rate: 1.5 Gbps
  programmed maximum physical link rate: 6 Gbps
  hardware maximum physical link rate: 6 Gbps
  phy change count: 45
  virtual phy: 0
  partial pathway timeout value: 7 us
  routing attribute: table
  connector type: SAS Drive backplane receptacle (SFF-8482) [max 2 phys]
  connector element index: 17
  connector physical link: 0
  phy power condition: 0
  sas power capable: 0
  sas slumber capable: 0
  sas partial capable: 0
  sata slumber capable: 0
  sata partial capable: 0
  pwr_dis signal: 0
  pwr_dis control capable: 0
  sas slumber enabled: 0
  sas partial enabled: 0
  sata slumber enabled: 0
  sata partial enabled: 0
  attached device name: 0x0
  requested inside ZPSDS changed by expander: 0
  inside ZPSDS persistent: 0
  requested inside ZPSDS: 0
  zone group persistent: 1
  inside ZPSDS: 0
  zoning enabled: 0
  zone group: 1
  self-configuration status: 0
  self-configuration levels completed: 0
  self-configuration sas address: 0x0
  programmed phy capabilities: 0x0
  current phy capabilities: 0x0
  attached phy capabilities: 0x0
  reason: unknown
  negotiated physical link rate: phy enabled, 6 Gbps
  optical mode enabled: 0
  negotiated SSC: 0
  hardware muxing supported: 0
  default inside ZPSDS persistent: 0
  default requested inside ZPSDS: 0
  default zone group persistent: 1
  default zoning enabled: 0
  default zone group: 1
  saved inside ZPSDS persistent: 0
  saved requested inside ZPSDS: 0
  saved zone group persistent: 1
  saved zoning enabled: 0
  saved zone group: 1
  shadow inside ZPSDS persistent: 0
  shadow requested inside ZPSDS: 0
  shadow zone group persistent: 1
  shadow zoning enabled: 0
  shadow zone group: 1
  device slot number: 255
  device slot group number: 255
  device slot group output connector:      =20
Discover response:
  expander change count: 1328
  phy identifier: 30
  attached device type: SAS or SATA device
  attached reason: unknown
  negotiated logical link rate: phy enabled, 6 Gbps
  attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0
  attached sata port selector: 0
  STP buffer too small: 0
  attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D1
  SAS address: 0x50030480017ae23f
  attached SAS address: 0x50030480017ae21e
  attached phy identifier: 0
  attached persistent capable: 0
  attached power capable: 0
  attached slumber capable: 0
  attached partial capable: 0
  attached inside ZPSDS persistent: 0
  attached requested inside ZPSDS: 0
  attached break_reply capable: 0
  attached pwr_dis capable: 0
  programmed minimum physical link rate: 1.5 Gbps
  hardware minimum physical link rate: 1.5 Gbps
  programmed maximum physical link rate: 6 Gbps
  hardware maximum physical link rate: 6 Gbps
  phy change count: 45
  virtual phy: 0
  partial pathway timeout value: 7 us
  routing attribute: table
  connector type: SAS Drive backplane receptacle (SFF-8482) [max 2 phys]
  connector element index: 18
  connector physical link: 0
  phy power condition: 0
  sas power capable: 0
  sas slumber capable: 0
  sas partial capable: 0
  sata slumber capable: 0
  sata partial capable: 0
  pwr_dis signal: 0
  pwr_dis control capable: 0
  sas slumber enabled: 0
  sas partial enabled: 0
  sata slumber enabled: 0
  sata partial enabled: 0
  attached device name: 0x0
  requested inside ZPSDS changed by expander: 0
  inside ZPSDS persistent: 0
  requested inside ZPSDS: 0
  zone group persistent: 1
  inside ZPSDS: 0
  zoning enabled: 0
  zone group: 1
  self-configuration status: 0
  self-configuration levels completed: 0
  self-configuration sas address: 0x0
  programmed phy capabilities: 0x0
  current phy capabilities: 0x0
  attached phy capabilities: 0x0
  reason: unknown
  negotiated physical link rate: phy enabled, 6 Gbps
  optical mode enabled: 0
  negotiated SSC: 0
  hardware muxing supported: 0
  default inside ZPSDS persistent: 0
  default requested inside ZPSDS: 0
  default zone group persistent: 1
  default zoning enabled: 0
  default zone group: 1
  saved inside ZPSDS persistent: 0
  saved requested inside ZPSDS: 0
  saved zone group persistent: 1
  saved zoning enabled: 0
  saved zone group: 1
  shadow inside ZPSDS persistent: 0
  shadow requested inside ZPSDS: 0
  shadow zone group persistent: 1
  shadow zoning enabled: 0
  shadow zone group: 1
  device slot number: 255
  device slot group number: 255
  device slot group output connector:      =20
Discover response:
  expander change count: 1328
  phy identifier: 31
  attached device type: SAS or SATA device
  attached reason: unknown
  negotiated logical link rate: phy enabled, 6 Gbps
  attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0
  attached sata port selector: 0
  STP buffer too small: 0
  attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D1
  SAS address: 0x50030480017ae23f
  attached SAS address: 0x50030480017ae21f
  attached phy identifier: 0
  attached persistent capable: 0
  attached power capable: 0
  attached slumber capable: 0
  attached partial capable: 0
  attached inside ZPSDS persistent: 0
  attached requested inside ZPSDS: 0
  attached break_reply capable: 0
  attached pwr_dis capable: 0
  programmed minimum physical link rate: 1.5 Gbps
  hardware minimum physical link rate: 1.5 Gbps
  programmed maximum physical link rate: 6 Gbps
  hardware maximum physical link rate: 6 Gbps
  phy change count: 45
  virtual phy: 0
  partial pathway timeout value: 7 us
  routing attribute: table
  connector type: SAS Drive backplane receptacle (SFF-8482) [max 2 phys]
  connector element index: 19
  connector physical link: 0
  phy power condition: 0
  sas power capable: 0
  sas slumber capable: 0
  sas partial capable: 0
  sata slumber capable: 0
  sata partial capable: 0
  pwr_dis signal: 0
  pwr_dis control capable: 0
  sas slumber enabled: 0
  sas partial enabled: 0
  sata slumber enabled: 0
  sata partial enabled: 0
  attached device name: 0x0
  requested inside ZPSDS changed by expander: 0
  inside ZPSDS persistent: 0
  requested inside ZPSDS: 0
  zone group persistent: 1
  inside ZPSDS: 0
  zoning enabled: 0
  zone group: 1
  self-configuration status: 0
  self-configuration levels completed: 0
  self-configuration sas address: 0x0
  programmed phy capabilities: 0x0
  current phy capabilities: 0x0
  attached phy capabilities: 0x0
  reason: unknown
  negotiated physical link rate: phy enabled, 6 Gbps
  optical mode enabled: 0
  negotiated SSC: 0
  hardware muxing supported: 0
  default inside ZPSDS persistent: 0
  default requested inside ZPSDS: 0
  default zone group persistent: 1
  default zoning enabled: 0
  default zone group: 1
  saved inside ZPSDS persistent: 0
  saved requested inside ZPSDS: 0
  saved zone group persistent: 1
  saved zoning enabled: 0
  saved zone group: 1
  shadow inside ZPSDS persistent: 0
  shadow requested inside ZPSDS: 0
  shadow zone group persistent: 1
  shadow zoning enabled: 0
  shadow zone group: 1
  device slot number: 255
  device slot group number: 255
  device slot group output connector:      =20
Discover response:
  expander change count: 1328
  phy identifier: 32
  attached device type: SAS or SATA device
  attached reason: unknown
  negotiated logical link rate: phy enabled, 6 Gbps
  attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0
  attached sata port selector: 0
  STP buffer too small: 0
  attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D1
  SAS address: 0x50030480017ae23f
  attached SAS address: 0x50030480017ae220
  attached phy identifier: 0
  attached persistent capable: 0
  attached power capable: 0
  attached slumber capable: 0
  attached partial capable: 0
  attached inside ZPSDS persistent: 0
  attached requested inside ZPSDS: 0
  attached break_reply capable: 0
  attached pwr_dis capable: 0
  programmed minimum physical link rate: 1.5 Gbps
  hardware minimum physical link rate: 1.5 Gbps
  programmed maximum physical link rate: 6 Gbps
  hardware maximum physical link rate: 6 Gbps
  phy change count: 45
  virtual phy: 0
  partial pathway timeout value: 7 us
  routing attribute: table
  connector type: SAS Drive backplane receptacle (SFF-8482) [max 2 phys]
  connector element index: 20
  connector physical link: 0
  phy power condition: 0
  sas power capable: 0
  sas slumber capable: 0
  sas partial capable: 0
  sata slumber capable: 0
  sata partial capable: 0
  pwr_dis signal: 0
  pwr_dis control capable: 0
  sas slumber enabled: 0
  sas partial enabled: 0
  sata slumber enabled: 0
  sata partial enabled: 0
  attached device name: 0x0
  requested inside ZPSDS changed by expander: 0
  inside ZPSDS persistent: 0
  requested inside ZPSDS: 0
  zone group persistent: 1
  inside ZPSDS: 0
  zoning enabled: 0
  zone group: 1
  self-configuration status: 0
  self-configuration levels completed: 0
  self-configuration sas address: 0x0
  programmed phy capabilities: 0x0
  current phy capabilities: 0x0
  attached phy capabilities: 0x0
  reason: unknown
  negotiated physical link rate: phy enabled, 6 Gbps
  optical mode enabled: 0
  negotiated SSC: 0
  hardware muxing supported: 0
  default inside ZPSDS persistent: 0
  default requested inside ZPSDS: 0
  default zone group persistent: 1
  default zoning enabled: 0
  default zone group: 1
  saved inside ZPSDS persistent: 0
  saved requested inside ZPSDS: 0
  saved zone group persistent: 1
  saved zoning enabled: 0
  saved zone group: 1
  shadow inside ZPSDS persistent: 0
  shadow requested inside ZPSDS: 0
  shadow zone group persistent: 1
  shadow zoning enabled: 0
  shadow zone group: 1
  device slot number: 255
  device slot group number: 255
  device slot group output connector:      =20
Discover response:
  expander change count: 1328
  phy identifier: 33
  attached device type: SAS or SATA device
  attached reason: unknown
  negotiated logical link rate: phy enabled, 6 Gbps
  attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0
  attached sata port selector: 0
  STP buffer too small: 0
  attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D1
  SAS address: 0x50030480017ae23f
  attached SAS address: 0x50030480017ae221
  attached phy identifier: 0
  attached persistent capable: 0
  attached power capable: 0
  attached slumber capable: 0
  attached partial capable: 0
  attached inside ZPSDS persistent: 0
  attached requested inside ZPSDS: 0
  attached break_reply capable: 0
  attached pwr_dis capable: 0
  programmed minimum physical link rate: 1.5 Gbps
  hardware minimum physical link rate: 1.5 Gbps
  programmed maximum physical link rate: 6 Gbps
  hardware maximum physical link rate: 6 Gbps
  phy change count: 45
  virtual phy: 0
  partial pathway timeout value: 7 us
  routing attribute: table
  connector type: SAS Drive backplane receptacle (SFF-8482) [max 2 phys]
  connector element index: 21
  connector physical link: 0
  phy power condition: 0
  sas power capable: 0
  sas slumber capable: 0
  sas partial capable: 0
  sata slumber capable: 0
  sata partial capable: 0
  pwr_dis signal: 0
  pwr_dis control capable: 0
  sas slumber enabled: 0
  sas partial enabled: 0
  sata slumber enabled: 0
  sata partial enabled: 0
  attached device name: 0x0
  requested inside ZPSDS changed by expander: 0
  inside ZPSDS persistent: 0
  requested inside ZPSDS: 0
  zone group persistent: 1
  inside ZPSDS: 0
  zoning enabled: 0
  zone group: 1
  self-configuration status: 0
  self-configuration levels completed: 0
  self-configuration sas address: 0x0
  programmed phy capabilities: 0x0
  current phy capabilities: 0x0
  attached phy capabilities: 0x0
  reason: unknown
  negotiated physical link rate: phy enabled, 6 Gbps
  optical mode enabled: 0
  negotiated SSC: 0
  hardware muxing supported: 0
  default inside ZPSDS persistent: 0
  default requested inside ZPSDS: 0
  default zone group persistent: 1
  default zoning enabled: 0
  default zone group: 1
  saved inside ZPSDS persistent: 0
  saved requested inside ZPSDS: 0
  saved zone group persistent: 1
  saved zoning enabled: 0
  saved zone group: 1
  shadow inside ZPSDS persistent: 0
  shadow requested inside ZPSDS: 0
  shadow zone group persistent: 1
  shadow zoning enabled: 0
  shadow zone group: 1
  device slot number: 255
  device slot group number: 255
  device slot group output connector:      =20
Discover response:
  expander change count: 1328
  phy identifier: 34
  attached device type: SAS or SATA device
  attached reason: unknown
  negotiated logical link rate: phy enabled, 6 Gbps
  attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0
  attached sata port selector: 0
  STP buffer too small: 0
  attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D1
  SAS address: 0x50030480017ae23f
  attached SAS address: 0x50030480017ae222
  attached phy identifier: 0
  attached persistent capable: 0
  attached power capable: 0
  attached slumber capable: 0
  attached partial capable: 0
  attached inside ZPSDS persistent: 0
  attached requested inside ZPSDS: 0
  attached break_reply capable: 0
  attached pwr_dis capable: 0
  programmed minimum physical link rate: 1.5 Gbps
  hardware minimum physical link rate: 1.5 Gbps
  programmed maximum physical link rate: 6 Gbps
  hardware maximum physical link rate: 6 Gbps
  phy change count: 45
  virtual phy: 0
  partial pathway timeout value: 7 us
  routing attribute: table
  connector type: SAS Drive backplane receptacle (SFF-8482) [max 2 phys]
  connector element index: 22
  connector physical link: 0
  phy power condition: 0
  sas power capable: 0
  sas slumber capable: 0
  sas partial capable: 0
  sata slumber capable: 0
  sata partial capable: 0
  pwr_dis signal: 0
  pwr_dis control capable: 0
  sas slumber enabled: 0
  sas partial enabled: 0
  sata slumber enabled: 0
  sata partial enabled: 0
  attached device name: 0x0
  requested inside ZPSDS changed by expander: 0
  inside ZPSDS persistent: 0
  requested inside ZPSDS: 0
  zone group persistent: 1
  inside ZPSDS: 0
  zoning enabled: 0
  zone group: 1
  self-configuration status: 0
  self-configuration levels completed: 0
  self-configuration sas address: 0x0
  programmed phy capabilities: 0x0
  current phy capabilities: 0x0
  attached phy capabilities: 0x0
  reason: unknown
  negotiated physical link rate: phy enabled, 6 Gbps
  optical mode enabled: 0
  negotiated SSC: 0
  hardware muxing supported: 0
  default inside ZPSDS persistent: 0
  default requested inside ZPSDS: 0
  default zone group persistent: 1
  default zoning enabled: 0
  default zone group: 1
  saved inside ZPSDS persistent: 0
  saved requested inside ZPSDS: 0
  saved zone group persistent: 1
  saved zoning enabled: 0
  saved zone group: 1
  shadow inside ZPSDS persistent: 0
  shadow requested inside ZPSDS: 0
  shadow zone group persistent: 1
  shadow zoning enabled: 0
  shadow zone group: 1
  device slot number: 255
  device slot group number: 255
  device slot group output connector:      =20
Discover response:
  expander change count: 1328
  phy identifier: 35
  attached device type: SAS or SATA device
  attached reason: unknown
  negotiated logical link rate: phy enabled, 6 Gbps
  attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0
  attached sata port selector: 0
  STP buffer too small: 0
  attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D1
  SAS address: 0x50030480017ae23f
  attached SAS address: 0x50030480017ae223
  attached phy identifier: 0
  attached persistent capable: 0
  attached power capable: 0
  attached slumber capable: 0
  attached partial capable: 0
  attached inside ZPSDS persistent: 0
  attached requested inside ZPSDS: 0
  attached break_reply capable: 0
  attached pwr_dis capable: 0
  programmed minimum physical link rate: 1.5 Gbps
  hardware minimum physical link rate: 1.5 Gbps
  programmed maximum physical link rate: 6 Gbps
  hardware maximum physical link rate: 6 Gbps
  phy change count: 45
  virtual phy: 0
  partial pathway timeout value: 7 us
  routing attribute: table
  connector type: SAS Drive backplane receptacle (SFF-8482) [max 2 phys]
  connector element index: 23
  connector physical link: 0
  phy power condition: 0
  sas power capable: 0
  sas slumber capable: 0
  sas partial capable: 0
  sata slumber capable: 0
  sata partial capable: 0
  pwr_dis signal: 0
  pwr_dis control capable: 0
  sas slumber enabled: 0
  sas partial enabled: 0
  sata slumber enabled: 0
  sata partial enabled: 0
  attached device name: 0x0
  requested inside ZPSDS changed by expander: 0
  inside ZPSDS persistent: 0
  requested inside ZPSDS: 0
  zone group persistent: 1
  inside ZPSDS: 0
  zoning enabled: 0
  zone group: 1
  self-configuration status: 0
  self-configuration levels completed: 0
  self-configuration sas address: 0x0
  programmed phy capabilities: 0x0
  current phy capabilities: 0x0
  attached phy capabilities: 0x0
  reason: unknown
  negotiated physical link rate: phy enabled, 6 Gbps
  optical mode enabled: 0
  negotiated SSC: 0
  hardware muxing supported: 0
  default inside ZPSDS persistent: 0
  default requested inside ZPSDS: 0
  default zone group persistent: 1
  default zoning enabled: 0
  default zone group: 1
  saved inside ZPSDS persistent: 0
  saved requested inside ZPSDS: 0
  saved zone group persistent: 1
  saved zoning enabled: 0
  saved zone group: 1
  shadow inside ZPSDS persistent: 0
  shadow requested inside ZPSDS: 0
  shadow zone group persistent: 1
  shadow zoning enabled: 0
  shadow zone group: 1
  device slot number: 255
  device slot group number: 255
  device slot group output connector:      =20
Discover response:
  expander change count: 1328
  phy identifier: 36
  attached device type: SAS or SATA device
  attached reason: unknown
  negotiated logical link rate: phy enabled, 6 Gbps
  attached initiator: ssp=3D1 stp=3D0 smp=3D1 sata_host=3D0
  attached sata port selector: 0
  STP buffer too small: 0
  attached target: ssp=3D1 stp=3D0 smp=3D0 sata_device=3D0
  SAS address: 0x50030480017ae23f
  attached SAS address: 0x50030480017ae23d
  attached phy identifier: 0
  attached persistent capable: 0
  attached power capable: 0
  attached slumber capable: 0
  attached partial capable: 0
  attached inside ZPSDS persistent: 0
  attached requested inside ZPSDS: 0
  attached break_reply capable: 0
  attached pwr_dis capable: 0
  programmed minimum physical link rate: 6 Gbps
  hardware minimum physical link rate: 6 Gbps
  programmed maximum physical link rate: 6 Gbps
  hardware maximum physical link rate: 6 Gbps
  phy change count: 1
  virtual phy: 1
  partial pathway timeout value: 7 us
  routing attribute: direct
  connector type: SAS virtual connector [max 1 phy]
  connector element index: 24
  connector physical link: 0
  phy power condition: 0
  sas power capable: 0
  sas slumber capable: 0
  sas partial capable: 0
  sata slumber capable: 0
  sata partial capable: 0
  pwr_dis signal: 0
  pwr_dis control capable: 0
  sas slumber enabled: 0
  sas partial enabled: 0
  sata slumber enabled: 0
  sata partial enabled: 0
  attached device name: 0x0
  requested inside ZPSDS changed by expander: 0
  inside ZPSDS persistent: 0
  requested inside ZPSDS: 0
  zone group persistent: 1
  inside ZPSDS: 1
  zoning enabled: 0
  zone group: 1
  self-configuration status: 0
  self-configuration levels completed: 0
  self-configuration sas address: 0x0
  programmed phy capabilities: 0x0
  current phy capabilities: 0x0
  attached phy capabilities: 0x0
  reason: unknown
  negotiated physical link rate: phy enabled, 6 Gbps
  optical mode enabled: 0
  negotiated SSC: 0
  hardware muxing supported: 0
  default inside ZPSDS persistent: 0
  default requested inside ZPSDS: 0
  default zone group persistent: 1
  default zoning enabled: 0
  default zone group: 1
  saved inside ZPSDS persistent: 0
  saved requested inside ZPSDS: 0
  saved zone group persistent: 1
  saved zoning enabled: 0
  saved zone group: 1
  shadow inside ZPSDS persistent: 0
  shadow requested inside ZPSDS: 0
  shadow zone group persistent: 1
  shadow zoning enabled: 0
  shadow zone group: 1
  device slot number: 255
  device slot group number: 255
  device slot group output connector:      =20



root@rhea:~ #  smp_discover ses1
  phy   0:S:attached:[50030480017ae23f:04 exp t(SMP)]  6 Gbps
  phy   1:S:attached:[50030480017ae23f:05 exp t(SMP)]  6 Gbps
  phy   2:S:attached:[50030480017ae23f:06 exp t(SMP)]  6 Gbps
  phy   3:S:attached:[50030480017ae23f:07 exp t(SMP)]  6 Gbps
  phy   8:D:disabled
  phy   9:D:disabled
  phy  10:D:disabled
  phy  11:D:disabled
  phy  12:U:attached:[50030480017bd5ac:00  t(SATA)]  6 Gbps
  phy  13:U:attached:[50030480017bd5ad:00  t(SATA)]  6 Gbps
  phy  14:U:attached:[50030480017bd5ae:00  t(SATA)]  6 Gbps
  phy  15:U:attached:[50030480017bd5af:00  t(SATA)]  6 Gbps
  phy  16:U:attached:[50030480017bd5b0:00  t(SATA)]  6 Gbps
  phy  17:U:attached:[50030480017bd5b1:00  t(SATA)]  6 Gbps
  phy  18:U:attached:[50030480017bd5b2:00  t(SATA)]  6 Gbps
  phy  19:U:attached:[50030480017bd5b3:00  t(SATA)]  6 Gbps
  phy  20:U:attached:[50030480017bd5b4:00  t(SATA)]  6 Gbps
  phy  21:U:attached:[50030480017bd5b5:00  t(SATA)]  6 Gbps
  phy  22:U:attached:[50030480017bd5b6:00  t(SATA)]  6 Gbps
  phy  23:U:attached:[50030480017bd5b7:00  t(SATA)]  6 Gbps
  phy  24:D:disabled
  phy  25:D:disabled
  phy  26:D:disabled
  phy  27:D:disabled
  phy  28:D:attached:[50030480017bd5bd:00  V i(SSP+SMP) t(SSP)]  6 Gbps
root@rhea:~ # foreach PHY ( `seq 0 1 28` )
foreach? smp_discover -p $PHY ses1
foreach? end
Discover response:
  expander change count: 241
  phy identifier: 0
  attached device type: expander device
  attached reason: loss of dword synchronization
  negotiated logical link rate: phy enabled, 6 Gbps
  attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0
  attached sata port selector: 0
  STP buffer too small: 0
  attached target: ssp=3D0 stp=3D0 smp=3D1 sata_device=3D0
  SAS address: 0x50030480017bd5bf
  attached SAS address: 0x50030480017ae23f
  attached phy identifier: 4
  attached persistent capable: 0
  attached power capable: 0
  attached slumber capable: 0
  attached partial capable: 0
  attached inside ZPSDS persistent: 0
  attached requested inside ZPSDS: 0
  attached break_reply capable: 1
  attached pwr_dis capable: 0
  programmed minimum physical link rate: 1.5 Gbps
  hardware minimum physical link rate: 1.5 Gbps
  programmed maximum physical link rate: 6 Gbps
  hardware maximum physical link rate: 6 Gbps
  phy change count: 1
  virtual phy: 0
  partial pathway timeout value: 7 us
  routing attribute: subtractive
  connector type: No information
  connector element index: 0
  connector physical link: 0
  phy power condition: 0
  sas power capable: 0
  sas slumber capable: 0
  sas partial capable: 0
  sata slumber capable: 0
  sata partial capable: 0
  pwr_dis signal: 0
  pwr_dis control capable: 0
  sas slumber enabled: 0
  sas partial enabled: 0
  sata slumber enabled: 0
  sata partial enabled: 0
  attached device name: 0x50030480017ae23f
  requested inside ZPSDS changed by expander: 0
  inside ZPSDS persistent: 0
  requested inside ZPSDS: 0
  zone group persistent: 1
  inside ZPSDS: 0
  zoning enabled: 0
  zone group: 1
  self-configuration status: 0
  self-configuration levels completed: 1
  self-configuration sas address: 0x0
  programmed phy capabilities: 0x0
  current phy capabilities: 0x0
  attached phy capabilities: 0x0
  reason: unknown
  negotiated physical link rate: phy enabled, 6 Gbps
  optical mode enabled: 0
  negotiated SSC: 0
  hardware muxing supported: 0
  default inside ZPSDS persistent: 0
  default requested inside ZPSDS: 0
  default zone group persistent: 1
  default zoning enabled: 0
  default zone group: 1
  saved inside ZPSDS persistent: 0
  saved requested inside ZPSDS: 0
  saved zone group persistent: 1
  saved zoning enabled: 0
  saved zone group: 1
  shadow inside ZPSDS persistent: 0
  shadow requested inside ZPSDS: 0
  shadow zone group persistent: 1
  shadow zoning enabled: 0
  shadow zone group: 1
  device slot number: 255
  device slot group number: 255
  device slot group output connector:      =20
Discover response:
  expander change count: 241
  phy identifier: 1
  attached device type: expander device
  attached reason: loss of dword synchronization
  negotiated logical link rate: phy enabled, 6 Gbps
  attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0
  attached sata port selector: 0
  STP buffer too small: 0
  attached target: ssp=3D0 stp=3D0 smp=3D1 sata_device=3D0
  SAS address: 0x50030480017bd5bf
  attached SAS address: 0x50030480017ae23f
  attached phy identifier: 5
  attached persistent capable: 0
  attached power capable: 0
  attached slumber capable: 0
  attached partial capable: 0
  attached inside ZPSDS persistent: 0
  attached requested inside ZPSDS: 0
  attached break_reply capable: 1
  attached pwr_dis capable: 0
  programmed minimum physical link rate: 1.5 Gbps
  hardware minimum physical link rate: 1.5 Gbps
  programmed maximum physical link rate: 6 Gbps
  hardware maximum physical link rate: 6 Gbps
  phy change count: 1
  virtual phy: 0
  partial pathway timeout value: 7 us
  routing attribute: subtractive
  connector type: No information
  connector element index: 0
  connector physical link: 0
  phy power condition: 0
  sas power capable: 0
  sas slumber capable: 0
  sas partial capable: 0
  sata slumber capable: 0
  sata partial capable: 0
  pwr_dis signal: 0
  pwr_dis control capable: 0
  sas slumber enabled: 0
  sas partial enabled: 0
  sata slumber enabled: 0
  sata partial enabled: 0
  attached device name: 0x50030480017ae23f
  requested inside ZPSDS changed by expander: 0
  inside ZPSDS persistent: 0
  requested inside ZPSDS: 0
  zone group persistent: 1
  inside ZPSDS: 0
  zoning enabled: 0
  zone group: 1
  self-configuration status: 0
  self-configuration levels completed: 1
  self-configuration sas address: 0x0
  programmed phy capabilities: 0x0
  current phy capabilities: 0x0
  attached phy capabilities: 0x0
  reason: unknown
  negotiated physical link rate: phy enabled, 6 Gbps
  optical mode enabled: 0
  negotiated SSC: 0
  hardware muxing supported: 0
  default inside ZPSDS persistent: 0
  default requested inside ZPSDS: 0
  default zone group persistent: 1
  default zoning enabled: 0
  default zone group: 1
  saved inside ZPSDS persistent: 0
  saved requested inside ZPSDS: 0
  saved zone group persistent: 1
  saved zoning enabled: 0
  saved zone group: 1
  shadow inside ZPSDS persistent: 0
  shadow requested inside ZPSDS: 0
  shadow zone group persistent: 1
  shadow zoning enabled: 0
  shadow zone group: 1
  device slot number: 255
  device slot group number: 255
  device slot group output connector:      =20
Discover response:
  expander change count: 241
  phy identifier: 2
  attached device type: expander device
  attached reason: loss of dword synchronization
  negotiated logical link rate: phy enabled, 6 Gbps
  attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0
  attached sata port selector: 0
  STP buffer too small: 0
  attached target: ssp=3D0 stp=3D0 smp=3D1 sata_device=3D0
  SAS address: 0x50030480017bd5bf
  attached SAS address: 0x50030480017ae23f
  attached phy identifier: 6
  attached persistent capable: 0
  attached power capable: 0
  attached slumber capable: 0
  attached partial capable: 0
  attached inside ZPSDS persistent: 0
  attached requested inside ZPSDS: 0
  attached break_reply capable: 1
  attached pwr_dis capable: 0
  programmed minimum physical link rate: 1.5 Gbps
  hardware minimum physical link rate: 1.5 Gbps
  programmed maximum physical link rate: 6 Gbps
  hardware maximum physical link rate: 6 Gbps
  phy change count: 1
  virtual phy: 0
  partial pathway timeout value: 7 us
  routing attribute: subtractive
  connector type: No information
  connector element index: 0
  connector physical link: 0
  phy power condition: 0
  sas power capable: 0
  sas slumber capable: 0
  sas partial capable: 0
  sata slumber capable: 0
  sata partial capable: 0
  pwr_dis signal: 0
  pwr_dis control capable: 0
  sas slumber enabled: 0
  sas partial enabled: 0
  sata slumber enabled: 0
  sata partial enabled: 0
  attached device name: 0x50030480017ae23f
  requested inside ZPSDS changed by expander: 0
  inside ZPSDS persistent: 0
  requested inside ZPSDS: 0
  zone group persistent: 1
  inside ZPSDS: 0
  zoning enabled: 0
  zone group: 1
  self-configuration status: 0
  self-configuration levels completed: 1
  self-configuration sas address: 0x0
  programmed phy capabilities: 0x0
  current phy capabilities: 0x0
  attached phy capabilities: 0x0
  reason: unknown
  negotiated physical link rate: phy enabled, 6 Gbps
  optical mode enabled: 0
  negotiated SSC: 0
  hardware muxing supported: 0
  default inside ZPSDS persistent: 0
  default requested inside ZPSDS: 0
  default zone group persistent: 1
  default zoning enabled: 0
  default zone group: 1
  saved inside ZPSDS persistent: 0
  saved requested inside ZPSDS: 0
  saved zone group persistent: 1
  saved zoning enabled: 0
  saved zone group: 1
  shadow inside ZPSDS persistent: 0
  shadow requested inside ZPSDS: 0
  shadow zone group persistent: 1
  shadow zoning enabled: 0
  shadow zone group: 1
  device slot number: 255
  device slot group number: 255
  device slot group output connector:      =20
Discover response:
  expander change count: 241
  phy identifier: 3
  attached device type: expander device
  attached reason: loss of dword synchronization
  negotiated logical link rate: phy enabled, 6 Gbps
  attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0
  attached sata port selector: 0
  STP buffer too small: 0
  attached target: ssp=3D0 stp=3D0 smp=3D1 sata_device=3D0
  SAS address: 0x50030480017bd5bf
  attached SAS address: 0x50030480017ae23f
  attached phy identifier: 7
  attached persistent capable: 0
  attached power capable: 0
  attached slumber capable: 0
  attached partial capable: 0
  attached inside ZPSDS persistent: 0
  attached requested inside ZPSDS: 0
  attached break_reply capable: 1
  attached pwr_dis capable: 0
  programmed minimum physical link rate: 1.5 Gbps
  hardware minimum physical link rate: 1.5 Gbps
  programmed maximum physical link rate: 6 Gbps
  hardware maximum physical link rate: 6 Gbps
  phy change count: 1
  virtual phy: 0
  partial pathway timeout value: 7 us
  routing attribute: subtractive
  connector type: No information
  connector element index: 0
  connector physical link: 0
  phy power condition: 0
  sas power capable: 0
  sas slumber capable: 0
  sas partial capable: 0
  sata slumber capable: 0
  sata partial capable: 0
  pwr_dis signal: 0
  pwr_dis control capable: 0
  sas slumber enabled: 0
  sas partial enabled: 0
  sata slumber enabled: 0
  sata partial enabled: 0
  attached device name: 0x50030480017ae23f
  requested inside ZPSDS changed by expander: 0
  inside ZPSDS persistent: 0
  requested inside ZPSDS: 0
  zone group persistent: 1
  inside ZPSDS: 0
  zoning enabled: 0
  zone group: 1
  self-configuration status: 0
  self-configuration levels completed: 1
  self-configuration sas address: 0x0
  programmed phy capabilities: 0x0
  current phy capabilities: 0x0
  attached phy capabilities: 0x0
  reason: unknown
  negotiated physical link rate: phy enabled, 6 Gbps
  optical mode enabled: 0
  negotiated SSC: 0
  hardware muxing supported: 0
  default inside ZPSDS persistent: 0
  default requested inside ZPSDS: 0
  default zone group persistent: 1
  default zoning enabled: 0
  default zone group: 1
  saved inside ZPSDS persistent: 0
  saved requested inside ZPSDS: 0
  saved zone group persistent: 1
  saved zoning enabled: 0
  saved zone group: 1
  shadow inside ZPSDS persistent: 0
  shadow requested inside ZPSDS: 0
  shadow zone group persistent: 1
  shadow zoning enabled: 0
  shadow zone group: 1
  device slot number: 255
  device slot group number: 255
  device slot group output connector:      =20
Discover response:
  expander change count: 241
  phy identifier: 4
  attached device type: no device attached
  attached reason: unknown
  negotiated logical link rate: phy enabled; unknown
  attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0
  attached sata port selector: 0
  STP buffer too small: 0
  attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D0
  SAS address: 0x50030480017bd5bf
  attached SAS address: 0x0
  attached phy identifier: 0
  attached persistent capable: 0
  attached power capable: 0
  attached slumber capable: 0
  attached partial capable: 0
  attached inside ZPSDS persistent: 0
  attached requested inside ZPSDS: 0
  attached break_reply capable: 0
  attached pwr_dis capable: 0
  programmed minimum physical link rate: 1.5 Gbps
  hardware minimum physical link rate: 1.5 Gbps
  programmed maximum physical link rate: 6 Gbps
  hardware maximum physical link rate: 6 Gbps
  phy change count: 1
  virtual phy: 0
  partial pathway timeout value: 7 us
  routing attribute: table
  connector type: No information
  connector element index: 0
  connector physical link: 0
  phy power condition: 0
  sas power capable: 0
  sas slumber capable: 0
  sas partial capable: 0
  sata slumber capable: 0
  sata partial capable: 0
  pwr_dis signal: 0
  pwr_dis control capable: 0
  sas slumber enabled: 0
  sas partial enabled: 0
  sata slumber enabled: 0
  sata partial enabled: 0
  attached device name: 0x0
  requested inside ZPSDS changed by expander: 0
  inside ZPSDS persistent: 0
  requested inside ZPSDS: 0
  zone group persistent: 1
  inside ZPSDS: 0
  zoning enabled: 0
  zone group: 1
  self-configuration status: 0
  self-configuration levels completed: 0
  self-configuration sas address: 0x0
  programmed phy capabilities: 0x0
  current phy capabilities: 0x0
  attached phy capabilities: 0x0
  reason: unknown
  negotiated physical link rate: phy enabled; unknown
  optical mode enabled: 0
  negotiated SSC: 0
  hardware muxing supported: 0
  default inside ZPSDS persistent: 0
  default requested inside ZPSDS: 0
  default zone group persistent: 1
  default zoning enabled: 0
  default zone group: 1
  saved inside ZPSDS persistent: 0
  saved requested inside ZPSDS: 0
  saved zone group persistent: 1
  saved zoning enabled: 0
  saved zone group: 1
  shadow inside ZPSDS persistent: 0
  shadow requested inside ZPSDS: 0
  shadow zone group persistent: 1
  shadow zoning enabled: 0
  shadow zone group: 1
  device slot number: 255
  device slot group number: 255
  device slot group output connector:      =20
Discover response:
  expander change count: 241
  phy identifier: 5
  attached device type: no device attached
  attached reason: unknown
  negotiated logical link rate: phy enabled; unknown
  attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0
  attached sata port selector: 0
  STP buffer too small: 0
  attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D0
  SAS address: 0x50030480017bd5bf
  attached SAS address: 0x0
  attached phy identifier: 0
  attached persistent capable: 0
  attached power capable: 0
  attached slumber capable: 0
  attached partial capable: 0
  attached inside ZPSDS persistent: 0
  attached requested inside ZPSDS: 0
  attached break_reply capable: 0
  attached pwr_dis capable: 0
  programmed minimum physical link rate: 1.5 Gbps
  hardware minimum physical link rate: 1.5 Gbps
  programmed maximum physical link rate: 6 Gbps
  hardware maximum physical link rate: 6 Gbps
  phy change count: 1
  virtual phy: 0
  partial pathway timeout value: 7 us
  routing attribute: table
  connector type: No information
  connector element index: 0
  connector physical link: 0
  phy power condition: 0
  sas power capable: 0
  sas slumber capable: 0
  sas partial capable: 0
  sata slumber capable: 0
  sata partial capable: 0
  pwr_dis signal: 0
  pwr_dis control capable: 0
  sas slumber enabled: 0
  sas partial enabled: 0
  sata slumber enabled: 0
  sata partial enabled: 0
  attached device name: 0x0
  requested inside ZPSDS changed by expander: 0
  inside ZPSDS persistent: 0
  requested inside ZPSDS: 0
  zone group persistent: 1
  inside ZPSDS: 0
  zoning enabled: 0
  zone group: 1
  self-configuration status: 0
  self-configuration levels completed: 0
  self-configuration sas address: 0x0
  programmed phy capabilities: 0x0
  current phy capabilities: 0x0
  attached phy capabilities: 0x0
  reason: unknown
  negotiated physical link rate: phy enabled; unknown
  optical mode enabled: 0
  negotiated SSC: 0
  hardware muxing supported: 0
  default inside ZPSDS persistent: 0
  default requested inside ZPSDS: 0
  default zone group persistent: 1
  default zoning enabled: 0
  default zone group: 1
  saved inside ZPSDS persistent: 0
  saved requested inside ZPSDS: 0
  saved zone group persistent: 1
  saved zoning enabled: 0
  saved zone group: 1
  shadow inside ZPSDS persistent: 0
  shadow requested inside ZPSDS: 0
  shadow zone group persistent: 1
  shadow zoning enabled: 0
  shadow zone group: 1
  device slot number: 255
  device slot group number: 255
  device slot group output connector:      =20
Discover response:
  expander change count: 241
  phy identifier: 6
  attached device type: no device attached
  attached reason: unknown
  negotiated logical link rate: phy enabled; unknown
  attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0
  attached sata port selector: 0
  STP buffer too small: 0
  attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D0
  SAS address: 0x50030480017bd5bf
  attached SAS address: 0x0
  attached phy identifier: 0
  attached persistent capable: 0
  attached power capable: 0
  attached slumber capable: 0
  attached partial capable: 0
  attached inside ZPSDS persistent: 0
  attached requested inside ZPSDS: 0
  attached break_reply capable: 0
  attached pwr_dis capable: 0
  programmed minimum physical link rate: 1.5 Gbps
  hardware minimum physical link rate: 1.5 Gbps
  programmed maximum physical link rate: 6 Gbps
  hardware maximum physical link rate: 6 Gbps
  phy change count: 1
  virtual phy: 0
  partial pathway timeout value: 7 us
  routing attribute: table
  connector type: No information
  connector element index: 0
  connector physical link: 0
  phy power condition: 0
  sas power capable: 0
  sas slumber capable: 0
  sas partial capable: 0
  sata slumber capable: 0
  sata partial capable: 0
  pwr_dis signal: 0
  pwr_dis control capable: 0
  sas slumber enabled: 0
  sas partial enabled: 0
  sata slumber enabled: 0
  sata partial enabled: 0
  attached device name: 0x0
  requested inside ZPSDS changed by expander: 0
  inside ZPSDS persistent: 0
  requested inside ZPSDS: 0
  zone group persistent: 1
  inside ZPSDS: 0
  zoning enabled: 0
  zone group: 1
  self-configuration status: 0
  self-configuration levels completed: 0
  self-configuration sas address: 0x0
  programmed phy capabilities: 0x0
  current phy capabilities: 0x0
  attached phy capabilities: 0x0
  reason: unknown
  negotiated physical link rate: phy enabled; unknown
  optical mode enabled: 0
  negotiated SSC: 0
  hardware muxing supported: 0
  default inside ZPSDS persistent: 0
  default requested inside ZPSDS: 0
  default zone group persistent: 1
  default zoning enabled: 0
  default zone group: 1
  saved inside ZPSDS persistent: 0
  saved requested inside ZPSDS: 0
  saved zone group persistent: 1
  saved zoning enabled: 0
  saved zone group: 1
  shadow inside ZPSDS persistent: 0
  shadow requested inside ZPSDS: 0
  shadow zone group persistent: 1
  shadow zoning enabled: 0
  shadow zone group: 1
  device slot number: 255
  device slot group number: 255
  device slot group output connector:      =20
Discover response:
  expander change count: 241
  phy identifier: 7
  attached device type: no device attached
  attached reason: unknown
  negotiated logical link rate: phy enabled; unknown
  attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0
  attached sata port selector: 0
  STP buffer too small: 0
  attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D0
  SAS address: 0x50030480017bd5bf
  attached SAS address: 0x0
  attached phy identifier: 0
  attached persistent capable: 0
  attached power capable: 0
  attached slumber capable: 0
  attached partial capable: 0
  attached inside ZPSDS persistent: 0
  attached requested inside ZPSDS: 0
  attached break_reply capable: 0
  attached pwr_dis capable: 0
  programmed minimum physical link rate: 1.5 Gbps
  hardware minimum physical link rate: 1.5 Gbps
  programmed maximum physical link rate: 6 Gbps
  hardware maximum physical link rate: 6 Gbps
  phy change count: 1
  virtual phy: 0
  partial pathway timeout value: 7 us
  routing attribute: table
  connector type: No information
  connector element index: 0
  connector physical link: 0
  phy power condition: 0
  sas power capable: 0
  sas slumber capable: 0
  sas partial capable: 0
  sata slumber capable: 0
  sata partial capable: 0
  pwr_dis signal: 0
  pwr_dis control capable: 0
  sas slumber enabled: 0
  sas partial enabled: 0
  sata slumber enabled: 0
  sata partial enabled: 0
  attached device name: 0x0
  requested inside ZPSDS changed by expander: 0
  inside ZPSDS persistent: 0
  requested inside ZPSDS: 0
  zone group persistent: 1
  inside ZPSDS: 0
  zoning enabled: 0
  zone group: 1
  self-configuration status: 0
  self-configuration levels completed: 0
  self-configuration sas address: 0x0
  programmed phy capabilities: 0x0
  current phy capabilities: 0x0
  attached phy capabilities: 0x0
  reason: unknown
  negotiated physical link rate: phy enabled; unknown
  optical mode enabled: 0
  negotiated SSC: 0
  hardware muxing supported: 0
  default inside ZPSDS persistent: 0
  default requested inside ZPSDS: 0
  default zone group persistent: 1
  default zoning enabled: 0
  default zone group: 1
  saved inside ZPSDS persistent: 0
  saved requested inside ZPSDS: 0
  saved zone group persistent: 1
  saved zoning enabled: 0
  saved zone group: 1
  shadow inside ZPSDS persistent: 0
  shadow requested inside ZPSDS: 0
  shadow zone group persistent: 1
  shadow zoning enabled: 0
  shadow zone group: 1
  device slot number: 255
  device slot group number: 255
  device slot group output connector:      =20
Discover response:
  expander change count: 241
  phy identifier: 8
  attached device type: no device attached
  attached reason: unknown
  negotiated logical link rate: phy disabled
  attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0
  attached sata port selector: 0
  STP buffer too small: 0
  attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D0
  SAS address: 0x50030480017bd5bf
  attached SAS address: 0x0
  attached phy identifier: 0
  attached persistent capable: 0
  attached power capable: 0
  attached slumber capable: 0
  attached partial capable: 0
  attached inside ZPSDS persistent: 0
  attached requested inside ZPSDS: 0
  attached break_reply capable: 0
  attached pwr_dis capable: 0
  programmed minimum physical link rate: 1.5 Gbps
  hardware minimum physical link rate: 1.5 Gbps
  programmed maximum physical link rate: 6 Gbps
  hardware maximum physical link rate: 6 Gbps
  phy change count: 1
  virtual phy: 0
  partial pathway timeout value: 7 us
  routing attribute: direct
  connector type: No information
  connector element index: 0
  connector physical link: 0
  phy power condition: 0
  sas power capable: 0
  sas slumber capable: 0
  sas partial capable: 0
  sata slumber capable: 0
  sata partial capable: 0
  pwr_dis signal: 0
  pwr_dis control capable: 0
  sas slumber enabled: 0
  sas partial enabled: 0
  sata slumber enabled: 0
  sata partial enabled: 0
  attached device name: 0x0
  requested inside ZPSDS changed by expander: 0
  inside ZPSDS persistent: 0
  requested inside ZPSDS: 0
  zone group persistent: 1
  inside ZPSDS: 0
  zoning enabled: 0
  zone group: 1
  self-configuration status: 0
  self-configuration levels completed: 0
  self-configuration sas address: 0x0
  programmed phy capabilities: 0x0
  current phy capabilities: 0x0
  attached phy capabilities: 0x0
  reason: unknown
  negotiated physical link rate: phy disabled
  optical mode enabled: 0
  negotiated SSC: 0
  hardware muxing supported: 0
  default inside ZPSDS persistent: 0
  default requested inside ZPSDS: 0
  default zone group persistent: 1
  default zoning enabled: 0
  default zone group: 1
  saved inside ZPSDS persistent: 0
  saved requested inside ZPSDS: 0
  saved zone group persistent: 1
  saved zoning enabled: 0
  saved zone group: 1
  shadow inside ZPSDS persistent: 0
  shadow requested inside ZPSDS: 0
  shadow zone group persistent: 1
  shadow zoning enabled: 0
  shadow zone group: 1
  device slot number: 255
  device slot group number: 255
  device slot group output connector:      =20
Discover response:
  expander change count: 241
  phy identifier: 9
  attached device type: no device attached
  attached reason: unknown
  negotiated logical link rate: phy disabled
  attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0
  attached sata port selector: 0
  STP buffer too small: 0
  attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D0
  SAS address: 0x50030480017bd5bf
  attached SAS address: 0x0
  attached phy identifier: 0
  attached persistent capable: 0
  attached power capable: 0
  attached slumber capable: 0
  attached partial capable: 0
  attached inside ZPSDS persistent: 0
  attached requested inside ZPSDS: 0
  attached break_reply capable: 0
  attached pwr_dis capable: 0
  programmed minimum physical link rate: 1.5 Gbps
  hardware minimum physical link rate: 1.5 Gbps
  programmed maximum physical link rate: 6 Gbps
  hardware maximum physical link rate: 6 Gbps
  phy change count: 1
  virtual phy: 0
  partial pathway timeout value: 7 us
  routing attribute: direct
  connector type: No information
  connector element index: 0
  connector physical link: 0
  phy power condition: 0
  sas power capable: 0
  sas slumber capable: 0
  sas partial capable: 0
  sata slumber capable: 0
  sata partial capable: 0
  pwr_dis signal: 0
  pwr_dis control capable: 0
  sas slumber enabled: 0
  sas partial enabled: 0
  sata slumber enabled: 0
  sata partial enabled: 0
  attached device name: 0x0
  requested inside ZPSDS changed by expander: 0
  inside ZPSDS persistent: 0
  requested inside ZPSDS: 0
  zone group persistent: 1
  inside ZPSDS: 0
  zoning enabled: 0
  zone group: 1
  self-configuration status: 0
  self-configuration levels completed: 0
  self-configuration sas address: 0x0
  programmed phy capabilities: 0x0
  current phy capabilities: 0x0
  attached phy capabilities: 0x0
  reason: unknown
  negotiated physical link rate: phy disabled
  optical mode enabled: 0
  negotiated SSC: 0
  hardware muxing supported: 0
  default inside ZPSDS persistent: 0
  default requested inside ZPSDS: 0
  default zone group persistent: 1
  default zoning enabled: 0
  default zone group: 1
  saved inside ZPSDS persistent: 0
  saved requested inside ZPSDS: 0
  saved zone group persistent: 1
  saved zoning enabled: 0
  saved zone group: 1
  shadow inside ZPSDS persistent: 0
  shadow requested inside ZPSDS: 0
  shadow zone group persistent: 1
  shadow zoning enabled: 0
  shadow zone group: 1
  device slot number: 255
  device slot group number: 255
  device slot group output connector:      =20
Discover response:
  expander change count: 241
  phy identifier: 10
  attached device type: no device attached
  attached reason: unknown
  negotiated logical link rate: phy disabled
  attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0
  attached sata port selector: 0
  STP buffer too small: 0
  attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D0
  SAS address: 0x50030480017bd5bf
  attached SAS address: 0x0
  attached phy identifier: 0
  attached persistent capable: 0
  attached power capable: 0
  attached slumber capable: 0
  attached partial capable: 0
  attached inside ZPSDS persistent: 0
  attached requested inside ZPSDS: 0
  attached break_reply capable: 0
  attached pwr_dis capable: 0
  programmed minimum physical link rate: 1.5 Gbps
  hardware minimum physical link rate: 1.5 Gbps
  programmed maximum physical link rate: 6 Gbps
  hardware maximum physical link rate: 6 Gbps
  phy change count: 1
  virtual phy: 0
  partial pathway timeout value: 7 us
  routing attribute: direct
  connector type: No information
  connector element index: 0
  connector physical link: 0
  phy power condition: 0
  sas power capable: 0
  sas slumber capable: 0
  sas partial capable: 0
  sata slumber capable: 0
  sata partial capable: 0
  pwr_dis signal: 0
  pwr_dis control capable: 0
  sas slumber enabled: 0
  sas partial enabled: 0
  sata slumber enabled: 0
  sata partial enabled: 0
  attached device name: 0x0
  requested inside ZPSDS changed by expander: 0
  inside ZPSDS persistent: 0
  requested inside ZPSDS: 0
  zone group persistent: 1
  inside ZPSDS: 0
  zoning enabled: 0
  zone group: 1
  self-configuration status: 0
  self-configuration levels completed: 0
  self-configuration sas address: 0x0
  programmed phy capabilities: 0x0
  current phy capabilities: 0x0
  attached phy capabilities: 0x0
  reason: unknown
  negotiated physical link rate: phy disabled
  optical mode enabled: 0
  negotiated SSC: 0
  hardware muxing supported: 0
  default inside ZPSDS persistent: 0
  default requested inside ZPSDS: 0
  default zone group persistent: 1
  default zoning enabled: 0
  default zone group: 1
  saved inside ZPSDS persistent: 0
  saved requested inside ZPSDS: 0
  saved zone group persistent: 1
  saved zoning enabled: 0
  saved zone group: 1
  shadow inside ZPSDS persistent: 0
  shadow requested inside ZPSDS: 0
  shadow zone group persistent: 1
  shadow zoning enabled: 0
  shadow zone group: 1
  device slot number: 255
  device slot group number: 255
  device slot group output connector:      =20
Discover response:
  expander change count: 241
  phy identifier: 11
  attached device type: no device attached
  attached reason: unknown
  negotiated logical link rate: phy disabled
  attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0
  attached sata port selector: 0
  STP buffer too small: 0
  attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D0
  SAS address: 0x50030480017bd5bf
  attached SAS address: 0x0
  attached phy identifier: 0
  attached persistent capable: 0
  attached power capable: 0
  attached slumber capable: 0
  attached partial capable: 0
  attached inside ZPSDS persistent: 0
  attached requested inside ZPSDS: 0
  attached break_reply capable: 0
  attached pwr_dis capable: 0
  programmed minimum physical link rate: 1.5 Gbps
  hardware minimum physical link rate: 1.5 Gbps
  programmed maximum physical link rate: 6 Gbps
  hardware maximum physical link rate: 6 Gbps
  phy change count: 1
  virtual phy: 0
  partial pathway timeout value: 7 us
  routing attribute: direct
  connector type: No information
  connector element index: 0
  connector physical link: 0
  phy power condition: 0
  sas power capable: 0
  sas slumber capable: 0
  sas partial capable: 0
  sata slumber capable: 0
  sata partial capable: 0
  pwr_dis signal: 0
  pwr_dis control capable: 0
  sas slumber enabled: 0
  sas partial enabled: 0
  sata slumber enabled: 0
  sata partial enabled: 0
  attached device name: 0x0
  requested inside ZPSDS changed by expander: 0
  inside ZPSDS persistent: 0
  requested inside ZPSDS: 0
  zone group persistent: 1
  inside ZPSDS: 0
  zoning enabled: 0
  zone group: 1
  self-configuration status: 0
  self-configuration levels completed: 0
  self-configuration sas address: 0x0
  programmed phy capabilities: 0x0
  current phy capabilities: 0x0
  attached phy capabilities: 0x0
  reason: unknown
  negotiated physical link rate: phy disabled
  optical mode enabled: 0
  negotiated SSC: 0
  hardware muxing supported: 0
  default inside ZPSDS persistent: 0
  default requested inside ZPSDS: 0
  default zone group persistent: 1
  default zoning enabled: 0
  default zone group: 1
  saved inside ZPSDS persistent: 0
  saved requested inside ZPSDS: 0
  saved zone group persistent: 1
  saved zoning enabled: 0
  saved zone group: 1
  shadow inside ZPSDS persistent: 0
  shadow requested inside ZPSDS: 0
  shadow zone group persistent: 1
  shadow zoning enabled: 0
  shadow zone group: 1
  device slot number: 255
  device slot group number: 255
  device slot group output connector:      =20
Discover response:
  expander change count: 241
  phy identifier: 12
  attached device type: SAS or SATA device
  attached reason: unknown
  negotiated logical link rate: phy enabled, 6 Gbps
  attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0
  attached sata port selector: 0
  STP buffer too small: 0
  attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D1
  SAS address: 0x50030480017bd5bf
  attached SAS address: 0x50030480017bd5ac
  attached phy identifier: 0
  attached persistent capable: 0
  attached power capable: 0
  attached slumber capable: 0
  attached partial capable: 0
  attached inside ZPSDS persistent: 0
  attached requested inside ZPSDS: 0
  attached break_reply capable: 0
  attached pwr_dis capable: 0
  programmed minimum physical link rate: 1.5 Gbps
  hardware minimum physical link rate: 1.5 Gbps
  programmed maximum physical link rate: 6 Gbps
  hardware maximum physical link rate: 6 Gbps
  phy change count: 21
  virtual phy: 0
  partial pathway timeout value: 7 us
  routing attribute: table
  connector type: SAS Drive backplane receptacle (SFF-8482) [max 2 phys]
  connector element index: 0
  connector physical link: 0
  phy power condition: 0
  sas power capable: 0
  sas slumber capable: 0
  sas partial capable: 0
  sata slumber capable: 0
  sata partial capable: 0
  pwr_dis signal: 0
  pwr_dis control capable: 0
  sas slumber enabled: 0
  sas partial enabled: 0
  sata slumber enabled: 0
  sata partial enabled: 0
  attached device name: 0x0
  requested inside ZPSDS changed by expander: 0
  inside ZPSDS persistent: 0
  requested inside ZPSDS: 0
  zone group persistent: 1
  inside ZPSDS: 0
  zoning enabled: 0
  zone group: 1
  self-configuration status: 0
  self-configuration levels completed: 0
  self-configuration sas address: 0x0
  programmed phy capabilities: 0x0
  current phy capabilities: 0x0
  attached phy capabilities: 0x0
  reason: unknown
  negotiated physical link rate: phy enabled, 6 Gbps
  optical mode enabled: 0
  negotiated SSC: 0
  hardware muxing supported: 0
  default inside ZPSDS persistent: 0
  default requested inside ZPSDS: 0
  default zone group persistent: 1
  default zoning enabled: 0
  default zone group: 1
  saved inside ZPSDS persistent: 0
  saved requested inside ZPSDS: 0
  saved zone group persistent: 1
  saved zoning enabled: 0
  saved zone group: 1
  shadow inside ZPSDS persistent: 0
  shadow requested inside ZPSDS: 0
  shadow zone group persistent: 1
  shadow zoning enabled: 0
  shadow zone group: 1
  device slot number: 255
  device slot group number: 255
  device slot group output connector:      =20
Discover response:
  expander change count: 241
  phy identifier: 13
  attached device type: SAS or SATA device
  attached reason: unknown
  negotiated logical link rate: phy enabled, 6 Gbps
  attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0
  attached sata port selector: 0
  STP buffer too small: 0
  attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D1
  SAS address: 0x50030480017bd5bf
  attached SAS address: 0x50030480017bd5ad
  attached phy identifier: 0
  attached persistent capable: 0
  attached power capable: 0
  attached slumber capable: 0
  attached partial capable: 0
  attached inside ZPSDS persistent: 0
  attached requested inside ZPSDS: 0
  attached break_reply capable: 0
  attached pwr_dis capable: 0
  programmed minimum physical link rate: 1.5 Gbps
  hardware minimum physical link rate: 1.5 Gbps
  programmed maximum physical link rate: 6 Gbps
  hardware maximum physical link rate: 6 Gbps
  phy change count: 19
  virtual phy: 0
  partial pathway timeout value: 7 us
  routing attribute: table
  connector type: SAS Drive backplane receptacle (SFF-8482) [max 2 phys]
  connector element index: 1
  connector physical link: 0
  phy power condition: 0
  sas power capable: 0
  sas slumber capable: 0
  sas partial capable: 0
  sata slumber capable: 0
  sata partial capable: 0
  pwr_dis signal: 0
  pwr_dis control capable: 0
  sas slumber enabled: 0
  sas partial enabled: 0
  sata slumber enabled: 0
  sata partial enabled: 0
  attached device name: 0x0
  requested inside ZPSDS changed by expander: 0
  inside ZPSDS persistent: 0
  requested inside ZPSDS: 0
  zone group persistent: 1
  inside ZPSDS: 0
  zoning enabled: 0
  zone group: 1
  self-configuration status: 0
  self-configuration levels completed: 0
  self-configuration sas address: 0x0
  programmed phy capabilities: 0x0
  current phy capabilities: 0x0
  attached phy capabilities: 0x0
  reason: unknown
  negotiated physical link rate: phy enabled, 6 Gbps
  optical mode enabled: 0
  negotiated SSC: 0
  hardware muxing supported: 0
  default inside ZPSDS persistent: 0
  default requested inside ZPSDS: 0
  default zone group persistent: 1
  default zoning enabled: 0
  default zone group: 1
  saved inside ZPSDS persistent: 0
  saved requested inside ZPSDS: 0
  saved zone group persistent: 1
  saved zoning enabled: 0
  saved zone group: 1
  shadow inside ZPSDS persistent: 0
  shadow requested inside ZPSDS: 0
  shadow zone group persistent: 1
  shadow zoning enabled: 0
  shadow zone group: 1
  device slot number: 255
  device slot group number: 255
  device slot group output connector:      =20
Discover response:
  expander change count: 241
  phy identifier: 14
  attached device type: SAS or SATA device
  attached reason: unknown
  negotiated logical link rate: phy enabled, 6 Gbps
  attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0
  attached sata port selector: 0
  STP buffer too small: 0
  attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D1
  SAS address: 0x50030480017bd5bf
  attached SAS address: 0x50030480017bd5ae
  attached phy identifier: 0
  attached persistent capable: 0
  attached power capable: 0
  attached slumber capable: 0
  attached partial capable: 0
  attached inside ZPSDS persistent: 0
  attached requested inside ZPSDS: 0
  attached break_reply capable: 0
  attached pwr_dis capable: 0
  programmed minimum physical link rate: 1.5 Gbps
  hardware minimum physical link rate: 1.5 Gbps
  programmed maximum physical link rate: 6 Gbps
  hardware maximum physical link rate: 6 Gbps
  phy change count: 19
  virtual phy: 0
  partial pathway timeout value: 7 us
  routing attribute: table
  connector type: SAS Drive backplane receptacle (SFF-8482) [max 2 phys]
  connector element index: 2
  connector physical link: 0
  phy power condition: 0
  sas power capable: 0
  sas slumber capable: 0
  sas partial capable: 0
  sata slumber capable: 0
  sata partial capable: 0
  pwr_dis signal: 0
  pwr_dis control capable: 0
  sas slumber enabled: 0
  sas partial enabled: 0
  sata slumber enabled: 0
  sata partial enabled: 0
  attached device name: 0x0
  requested inside ZPSDS changed by expander: 0
  inside ZPSDS persistent: 0
  requested inside ZPSDS: 0
  zone group persistent: 1
  inside ZPSDS: 0
  zoning enabled: 0
  zone group: 1
  self-configuration status: 0
  self-configuration levels completed: 0
  self-configuration sas address: 0x0
  programmed phy capabilities: 0x0
  current phy capabilities: 0x0
  attached phy capabilities: 0x0
  reason: unknown
  negotiated physical link rate: phy enabled, 6 Gbps
  optical mode enabled: 0
  negotiated SSC: 0
  hardware muxing supported: 0
  default inside ZPSDS persistent: 0
  default requested inside ZPSDS: 0
  default zone group persistent: 1
  default zoning enabled: 0
  default zone group: 1
  saved inside ZPSDS persistent: 0
  saved requested inside ZPSDS: 0
  saved zone group persistent: 1
  saved zoning enabled: 0
  saved zone group: 1
  shadow inside ZPSDS persistent: 0
  shadow requested inside ZPSDS: 0
  shadow zone group persistent: 1
  shadow zoning enabled: 0
  shadow zone group: 1
  device slot number: 255
  device slot group number: 255
  device slot group output connector:      =20
Discover response:
  expander change count: 241
  phy identifier: 15
  attached device type: SAS or SATA device
  attached reason: unknown
  negotiated logical link rate: phy enabled, 6 Gbps
  attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0
  attached sata port selector: 0
  STP buffer too small: 0
  attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D1
  SAS address: 0x50030480017bd5bf
  attached SAS address: 0x50030480017bd5af
  attached phy identifier: 0
  attached persistent capable: 0
  attached power capable: 0
  attached slumber capable: 0
  attached partial capable: 0
  attached inside ZPSDS persistent: 0
  attached requested inside ZPSDS: 0
  attached break_reply capable: 0
  attached pwr_dis capable: 0
  programmed minimum physical link rate: 1.5 Gbps
  hardware minimum physical link rate: 1.5 Gbps
  programmed maximum physical link rate: 6 Gbps
  hardware maximum physical link rate: 6 Gbps
  phy change count: 18
  virtual phy: 0
  partial pathway timeout value: 7 us
  routing attribute: table
  connector type: SAS Drive backplane receptacle (SFF-8482) [max 2 phys]
  connector element index: 3
  connector physical link: 0
  phy power condition: 0
  sas power capable: 0
  sas slumber capable: 0
  sas partial capable: 0
  sata slumber capable: 0
  sata partial capable: 0
  pwr_dis signal: 0
  pwr_dis control capable: 0
  sas slumber enabled: 0
  sas partial enabled: 0
  sata slumber enabled: 0
  sata partial enabled: 0
  attached device name: 0x0
  requested inside ZPSDS changed by expander: 0
  inside ZPSDS persistent: 0
  requested inside ZPSDS: 0
  zone group persistent: 1
  inside ZPSDS: 0
  zoning enabled: 0
  zone group: 1
  self-configuration status: 0
  self-configuration levels completed: 0
  self-configuration sas address: 0x0
  programmed phy capabilities: 0x0
  current phy capabilities: 0x0
  attached phy capabilities: 0x0
  reason: unknown
  negotiated physical link rate: phy enabled, 6 Gbps
  optical mode enabled: 0
  negotiated SSC: 0
  hardware muxing supported: 0
  default inside ZPSDS persistent: 0
  default requested inside ZPSDS: 0
  default zone group persistent: 1
  default zoning enabled: 0
  default zone group: 1
  saved inside ZPSDS persistent: 0
  saved requested inside ZPSDS: 0
  saved zone group persistent: 1
  saved zoning enabled: 0
  saved zone group: 1
  shadow inside ZPSDS persistent: 0
  shadow requested inside ZPSDS: 0
  shadow zone group persistent: 1
  shadow zoning enabled: 0
  shadow zone group: 1
  device slot number: 255
  device slot group number: 255
  device slot group output connector:      =20
Discover response:
  expander change count: 241
  phy identifier: 16
  attached device type: SAS or SATA device
  attached reason: unknown
  negotiated logical link rate: phy enabled, 6 Gbps
  attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0
  attached sata port selector: 0
  STP buffer too small: 0
  attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D1
  SAS address: 0x50030480017bd5bf
  attached SAS address: 0x50030480017bd5b0
  attached phy identifier: 0
  attached persistent capable: 0
  attached power capable: 0
  attached slumber capable: 0
  attached partial capable: 0
  attached inside ZPSDS persistent: 0
  attached requested inside ZPSDS: 0
  attached break_reply capable: 0
  attached pwr_dis capable: 0
  programmed minimum physical link rate: 1.5 Gbps
  hardware minimum physical link rate: 1.5 Gbps
  programmed maximum physical link rate: 6 Gbps
  hardware maximum physical link rate: 6 Gbps
  phy change count: 19
  virtual phy: 0
  partial pathway timeout value: 7 us
  routing attribute: table
  connector type: SAS Drive backplane receptacle (SFF-8482) [max 2 phys]
  connector element index: 4
  connector physical link: 0
  phy power condition: 0
  sas power capable: 0
  sas slumber capable: 0
  sas partial capable: 0
  sata slumber capable: 0
  sata partial capable: 0
  pwr_dis signal: 0
  pwr_dis control capable: 0
  sas slumber enabled: 0
  sas partial enabled: 0
  sata slumber enabled: 0
  sata partial enabled: 0
  attached device name: 0x0
  requested inside ZPSDS changed by expander: 0
  inside ZPSDS persistent: 0
  requested inside ZPSDS: 0
  zone group persistent: 1
  inside ZPSDS: 0
  zoning enabled: 0
  zone group: 1
  self-configuration status: 0
  self-configuration levels completed: 0
  self-configuration sas address: 0x0
  programmed phy capabilities: 0x0
  current phy capabilities: 0x0
  attached phy capabilities: 0x0
  reason: unknown
  negotiated physical link rate: phy enabled, 6 Gbps
  optical mode enabled: 0
  negotiated SSC: 0
  hardware muxing supported: 0
  default inside ZPSDS persistent: 0
  default requested inside ZPSDS: 0
  default zone group persistent: 1
  default zoning enabled: 0
  default zone group: 1
  saved inside ZPSDS persistent: 0
  saved requested inside ZPSDS: 0
  saved zone group persistent: 1
  saved zoning enabled: 0
  saved zone group: 1
  shadow inside ZPSDS persistent: 0
  shadow requested inside ZPSDS: 0
  shadow zone group persistent: 1
  shadow zoning enabled: 0
  shadow zone group: 1
  device slot number: 255
  device slot group number: 255
  device slot group output connector:      =20
Discover response:
  expander change count: 241
  phy identifier: 17
  attached device type: SAS or SATA device
  attached reason: unknown
  negotiated logical link rate: phy enabled, 6 Gbps
  attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0
  attached sata port selector: 0
  STP buffer too small: 0
  attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D1
  SAS address: 0x50030480017bd5bf
  attached SAS address: 0x50030480017bd5b1
  attached phy identifier: 0
  attached persistent capable: 0
  attached power capable: 0
  attached slumber capable: 0
  attached partial capable: 0
  attached inside ZPSDS persistent: 0
  attached requested inside ZPSDS: 0
  attached break_reply capable: 0
  attached pwr_dis capable: 0
  programmed minimum physical link rate: 1.5 Gbps
  hardware minimum physical link rate: 1.5 Gbps
  programmed maximum physical link rate: 6 Gbps
  hardware maximum physical link rate: 6 Gbps
  phy change count: 18
  virtual phy: 0
  partial pathway timeout value: 7 us
  routing attribute: table
  connector type: SAS Drive backplane receptacle (SFF-8482) [max 2 phys]
  connector element index: 5
  connector physical link: 0
  phy power condition: 0
  sas power capable: 0
  sas slumber capable: 0
  sas partial capable: 0
  sata slumber capable: 0
  sata partial capable: 0
  pwr_dis signal: 0
  pwr_dis control capable: 0
  sas slumber enabled: 0
  sas partial enabled: 0
  sata slumber enabled: 0
  sata partial enabled: 0
  attached device name: 0x0
  requested inside ZPSDS changed by expander: 0
  inside ZPSDS persistent: 0
  requested inside ZPSDS: 0
  zone group persistent: 1
  inside ZPSDS: 0
  zoning enabled: 0
  zone group: 1
  self-configuration status: 0
  self-configuration levels completed: 0
  self-configuration sas address: 0x0
  programmed phy capabilities: 0x0
  current phy capabilities: 0x0
  attached phy capabilities: 0x0
  reason: unknown
  negotiated physical link rate: phy enabled, 6 Gbps
  optical mode enabled: 0
  negotiated SSC: 0
  hardware muxing supported: 0
  default inside ZPSDS persistent: 0
  default requested inside ZPSDS: 0
  default zone group persistent: 1
  default zoning enabled: 0
  default zone group: 1
  saved inside ZPSDS persistent: 0
  saved requested inside ZPSDS: 0
  saved zone group persistent: 1
  saved zoning enabled: 0
  saved zone group: 1
  shadow inside ZPSDS persistent: 0
  shadow requested inside ZPSDS: 0
  shadow zone group persistent: 1
  shadow zoning enabled: 0
  shadow zone group: 1
  device slot number: 255
  device slot group number: 255
  device slot group output connector:      =20
Discover response:
  expander change count: 241
  phy identifier: 18
  attached device type: SAS or SATA device
  attached reason: unknown
  negotiated logical link rate: phy enabled, 6 Gbps
  attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0
  attached sata port selector: 0
  STP buffer too small: 0
  attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D1
  SAS address: 0x50030480017bd5bf
  attached SAS address: 0x50030480017bd5b2
  attached phy identifier: 0
  attached persistent capable: 0
  attached power capable: 0
  attached slumber capable: 0
  attached partial capable: 0
  attached inside ZPSDS persistent: 0
  attached requested inside ZPSDS: 0
  attached break_reply capable: 0
  attached pwr_dis capable: 0
  programmed minimum physical link rate: 1.5 Gbps
  hardware minimum physical link rate: 1.5 Gbps
  programmed maximum physical link rate: 6 Gbps
  hardware maximum physical link rate: 6 Gbps
  phy change count: 18
  virtual phy: 0
  partial pathway timeout value: 7 us
  routing attribute: table
  connector type: SAS Drive backplane receptacle (SFF-8482) [max 2 phys]
  connector element index: 6
  connector physical link: 0
  phy power condition: 0
  sas power capable: 0
  sas slumber capable: 0
  sas partial capable: 0
  sata slumber capable: 0
  sata partial capable: 0
  pwr_dis signal: 0
  pwr_dis control capable: 0
  sas slumber enabled: 0
  sas partial enabled: 0
  sata slumber enabled: 0
  sata partial enabled: 0
  attached device name: 0x0
  requested inside ZPSDS changed by expander: 0
  inside ZPSDS persistent: 0
  requested inside ZPSDS: 0
  zone group persistent: 1
  inside ZPSDS: 0
  zoning enabled: 0
  zone group: 1
  self-configuration status: 0
  self-configuration levels completed: 0
  self-configuration sas address: 0x0
  programmed phy capabilities: 0x0
  current phy capabilities: 0x0
  attached phy capabilities: 0x0
  reason: unknown
  negotiated physical link rate: phy enabled, 6 Gbps
  optical mode enabled: 0
  negotiated SSC: 0
  hardware muxing supported: 0
  default inside ZPSDS persistent: 0
  default requested inside ZPSDS: 0
  default zone group persistent: 1
  default zoning enabled: 0
  default zone group: 1
  saved inside ZPSDS persistent: 0
  saved requested inside ZPSDS: 0
  saved zone group persistent: 1
  saved zoning enabled: 0
  saved zone group: 1
  shadow inside ZPSDS persistent: 0
  shadow requested inside ZPSDS: 0
  shadow zone group persistent: 1
  shadow zoning enabled: 0
  shadow zone group: 1
  device slot number: 255
  device slot group number: 255
  device slot group output connector:      =20
Discover response:
  expander change count: 241
  phy identifier: 19
  attached device type: SAS or SATA device
  attached reason: unknown
  negotiated logical link rate: phy enabled, 6 Gbps
  attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0
  attached sata port selector: 0
  STP buffer too small: 0
  attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D1
  SAS address: 0x50030480017bd5bf
  attached SAS address: 0x50030480017bd5b3
  attached phy identifier: 0
  attached persistent capable: 0
  attached power capable: 0
  attached slumber capable: 0
  attached partial capable: 0
  attached inside ZPSDS persistent: 0
  attached requested inside ZPSDS: 0
  attached break_reply capable: 0
  attached pwr_dis capable: 0
  programmed minimum physical link rate: 1.5 Gbps
  hardware minimum physical link rate: 1.5 Gbps
  programmed maximum physical link rate: 6 Gbps
  hardware maximum physical link rate: 6 Gbps
  phy change count: 18
  virtual phy: 0
  partial pathway timeout value: 7 us
  routing attribute: table
  connector type: SAS Drive backplane receptacle (SFF-8482) [max 2 phys]
  connector element index: 7
  connector physical link: 0
  phy power condition: 0
  sas power capable: 0
  sas slumber capable: 0
  sas partial capable: 0
  sata slumber capable: 0
  sata partial capable: 0
  pwr_dis signal: 0
  pwr_dis control capable: 0
  sas slumber enabled: 0
  sas partial enabled: 0
  sata slumber enabled: 0
  sata partial enabled: 0
  attached device name: 0x0
  requested inside ZPSDS changed by expander: 0
  inside ZPSDS persistent: 0
  requested inside ZPSDS: 0
  zone group persistent: 1
  inside ZPSDS: 0
  zoning enabled: 0
  zone group: 1
  self-configuration status: 0
  self-configuration levels completed: 0
  self-configuration sas address: 0x0
  programmed phy capabilities: 0x0
  current phy capabilities: 0x0
  attached phy capabilities: 0x0
  reason: unknown
  negotiated physical link rate: phy enabled, 6 Gbps
  optical mode enabled: 0
  negotiated SSC: 0
  hardware muxing supported: 0
  default inside ZPSDS persistent: 0
  default requested inside ZPSDS: 0
  default zone group persistent: 1
  default zoning enabled: 0
  default zone group: 1
  saved inside ZPSDS persistent: 0
  saved requested inside ZPSDS: 0
  saved zone group persistent: 1
  saved zoning enabled: 0
  saved zone group: 1
  shadow inside ZPSDS persistent: 0
  shadow requested inside ZPSDS: 0
  shadow zone group persistent: 1
  shadow zoning enabled: 0
  shadow zone group: 1
  device slot number: 255
  device slot group number: 255
  device slot group output connector:      =20
Discover response:
  expander change count: 241
  phy identifier: 20
  attached device type: SAS or SATA device
  attached reason: unknown
  negotiated logical link rate: phy enabled, 6 Gbps
  attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0
  attached sata port selector: 0
  STP buffer too small: 0
  attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D1
  SAS address: 0x50030480017bd5bf
  attached SAS address: 0x50030480017bd5b4
  attached phy identifier: 0
  attached persistent capable: 0
  attached power capable: 0
  attached slumber capable: 0
  attached partial capable: 0
  attached inside ZPSDS persistent: 0
  attached requested inside ZPSDS: 0
  attached break_reply capable: 0
  attached pwr_dis capable: 0
  programmed minimum physical link rate: 1.5 Gbps
  hardware minimum physical link rate: 1.5 Gbps
  programmed maximum physical link rate: 6 Gbps
  hardware maximum physical link rate: 6 Gbps
  phy change count: 18
  virtual phy: 0
  partial pathway timeout value: 7 us
  routing attribute: table
  connector type: SAS Drive backplane receptacle (SFF-8482) [max 2 phys]
  connector element index: 8
  connector physical link: 0
  phy power condition: 0
  sas power capable: 0
  sas slumber capable: 0
  sas partial capable: 0
  sata slumber capable: 0
  sata partial capable: 0
  pwr_dis signal: 0
  pwr_dis control capable: 0
  sas slumber enabled: 0
  sas partial enabled: 0
  sata slumber enabled: 0
  sata partial enabled: 0
  attached device name: 0x0
  requested inside ZPSDS changed by expander: 0
  inside ZPSDS persistent: 0
  requested inside ZPSDS: 0
  zone group persistent: 1
  inside ZPSDS: 0
  zoning enabled: 0
  zone group: 1
  self-configuration status: 0
  self-configuration levels completed: 0
  self-configuration sas address: 0x0
  programmed phy capabilities: 0x0
  current phy capabilities: 0x0
  attached phy capabilities: 0x0
  reason: unknown
  negotiated physical link rate: phy enabled, 6 Gbps
  optical mode enabled: 0
  negotiated SSC: 0
  hardware muxing supported: 0
  default inside ZPSDS persistent: 0
  default requested inside ZPSDS: 0
  default zone group persistent: 1
  default zoning enabled: 0
  default zone group: 1
  saved inside ZPSDS persistent: 0
  saved requested inside ZPSDS: 0
  saved zone group persistent: 1
  saved zoning enabled: 0
  saved zone group: 1
  shadow inside ZPSDS persistent: 0
  shadow requested inside ZPSDS: 0
  shadow zone group persistent: 1
  shadow zoning enabled: 0
  shadow zone group: 1
  device slot number: 255
  device slot group number: 255
  device slot group output connector:      =20
Discover response:
  expander change count: 241
  phy identifier: 21
  attached device type: SAS or SATA device
  attached reason: unknown
  negotiated logical link rate: phy enabled, 6 Gbps
  attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0
  attached sata port selector: 0
  STP buffer too small: 0
  attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D1
  SAS address: 0x50030480017bd5bf
  attached SAS address: 0x50030480017bd5b5
  attached phy identifier: 0
  attached persistent capable: 0
  attached power capable: 0
  attached slumber capable: 0
  attached partial capable: 0
  attached inside ZPSDS persistent: 0
  attached requested inside ZPSDS: 0
  attached break_reply capable: 0
  attached pwr_dis capable: 0
  programmed minimum physical link rate: 1.5 Gbps
  hardware minimum physical link rate: 1.5 Gbps
  programmed maximum physical link rate: 6 Gbps
  hardware maximum physical link rate: 6 Gbps
  phy change count: 18
  virtual phy: 0
  partial pathway timeout value: 7 us
  routing attribute: table
  connector type: SAS Drive backplane receptacle (SFF-8482) [max 2 phys]
  connector element index: 9
  connector physical link: 0
  phy power condition: 0
  sas power capable: 0
  sas slumber capable: 0
  sas partial capable: 0
  sata slumber capable: 0
  sata partial capable: 0
  pwr_dis signal: 0
  pwr_dis control capable: 0
  sas slumber enabled: 0
  sas partial enabled: 0
  sata slumber enabled: 0
  sata partial enabled: 0
  attached device name: 0x0
  requested inside ZPSDS changed by expander: 0
  inside ZPSDS persistent: 0
  requested inside ZPSDS: 0
  zone group persistent: 1
  inside ZPSDS: 0
  zoning enabled: 0
  zone group: 1
  self-configuration status: 0
  self-configuration levels completed: 0
  self-configuration sas address: 0x0
  programmed phy capabilities: 0x0
  current phy capabilities: 0x0
  attached phy capabilities: 0x0
  reason: unknown
  negotiated physical link rate: phy enabled, 6 Gbps
  optical mode enabled: 0
  negotiated SSC: 0
  hardware muxing supported: 0
  default inside ZPSDS persistent: 0
  default requested inside ZPSDS: 0
  default zone group persistent: 1
  default zoning enabled: 0
  default zone group: 1
  saved inside ZPSDS persistent: 0
  saved requested inside ZPSDS: 0
  saved zone group persistent: 1
  saved zoning enabled: 0
  saved zone group: 1
  shadow inside ZPSDS persistent: 0
  shadow requested inside ZPSDS: 0
  shadow zone group persistent: 1
  shadow zoning enabled: 0
  shadow zone group: 1
  device slot number: 255
  device slot group number: 255
  device slot group output connector:      =20
Discover response:
  expander change count: 241
  phy identifier: 22
  attached device type: SAS or SATA device
  attached reason: unknown
  negotiated logical link rate: phy enabled, 6 Gbps
  attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0
  attached sata port selector: 0
  STP buffer too small: 0
  attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D1
  SAS address: 0x50030480017bd5bf
  attached SAS address: 0x50030480017bd5b6
  attached phy identifier: 0
  attached persistent capable: 0
  attached power capable: 0
  attached slumber capable: 0
  attached partial capable: 0
  attached inside ZPSDS persistent: 0
  attached requested inside ZPSDS: 0
  attached break_reply capable: 0
  attached pwr_dis capable: 0
  programmed minimum physical link rate: 1.5 Gbps
  hardware minimum physical link rate: 1.5 Gbps
  programmed maximum physical link rate: 6 Gbps
  hardware maximum physical link rate: 6 Gbps
  phy change count: 18
  virtual phy: 0
  partial pathway timeout value: 7 us
  routing attribute: table
  connector type: SAS Drive backplane receptacle (SFF-8482) [max 2 phys]
  connector element index: 10
  connector physical link: 0
  phy power condition: 0
  sas power capable: 0
  sas slumber capable: 0
  sas partial capable: 0
  sata slumber capable: 0
  sata partial capable: 0
  pwr_dis signal: 0
  pwr_dis control capable: 0
  sas slumber enabled: 0
  sas partial enabled: 0
  sata slumber enabled: 0
  sata partial enabled: 0
  attached device name: 0x0
  requested inside ZPSDS changed by expander: 0
  inside ZPSDS persistent: 0
  requested inside ZPSDS: 0
  zone group persistent: 1
  inside ZPSDS: 0
  zoning enabled: 0
  zone group: 1
  self-configuration status: 0
  self-configuration levels completed: 0
  self-configuration sas address: 0x0
  programmed phy capabilities: 0x0
  current phy capabilities: 0x0
  attached phy capabilities: 0x0
  reason: unknown
  negotiated physical link rate: phy enabled, 6 Gbps
  optical mode enabled: 0
  negotiated SSC: 0
  hardware muxing supported: 0
  default inside ZPSDS persistent: 0
  default requested inside ZPSDS: 0
  default zone group persistent: 1
  default zoning enabled: 0
  default zone group: 1
  saved inside ZPSDS persistent: 0
  saved requested inside ZPSDS: 0
  saved zone group persistent: 1
  saved zoning enabled: 0
  saved zone group: 1
  shadow inside ZPSDS persistent: 0
  shadow requested inside ZPSDS: 0
  shadow zone group persistent: 1
  shadow zoning enabled: 0
  shadow zone group: 1
  device slot number: 255
  device slot group number: 255
  device slot group output connector:      =20
Discover response:
  expander change count: 241
  phy identifier: 23
  attached device type: SAS or SATA device
  attached reason: unknown
  negotiated logical link rate: phy enabled, 6 Gbps
  attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0
  attached sata port selector: 0
  STP buffer too small: 0
  attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D1
  SAS address: 0x50030480017bd5bf
  attached SAS address: 0x50030480017bd5b7
  attached phy identifier: 0
  attached persistent capable: 0
  attached power capable: 0
  attached slumber capable: 0
  attached partial capable: 0
  attached inside ZPSDS persistent: 0
  attached requested inside ZPSDS: 0
  attached break_reply capable: 0
  attached pwr_dis capable: 0
  programmed minimum physical link rate: 1.5 Gbps
  hardware minimum physical link rate: 1.5 Gbps
  programmed maximum physical link rate: 6 Gbps
  hardware maximum physical link rate: 6 Gbps
  phy change count: 18
  virtual phy: 0
  partial pathway timeout value: 7 us
  routing attribute: table
  connector type: SAS Drive backplane receptacle (SFF-8482) [max 2 phys]
  connector element index: 11
  connector physical link: 0
  phy power condition: 0
  sas power capable: 0
  sas slumber capable: 0
  sas partial capable: 0
  sata slumber capable: 0
  sata partial capable: 0
  pwr_dis signal: 0
  pwr_dis control capable: 0
  sas slumber enabled: 0
  sas partial enabled: 0
  sata slumber enabled: 0
  sata partial enabled: 0
  attached device name: 0x0
  requested inside ZPSDS changed by expander: 0
  inside ZPSDS persistent: 0
  requested inside ZPSDS: 0
  zone group persistent: 1
  inside ZPSDS: 0
  zoning enabled: 0
  zone group: 1
  self-configuration status: 0
  self-configuration levels completed: 0
  self-configuration sas address: 0x0
  programmed phy capabilities: 0x0
  current phy capabilities: 0x0
  attached phy capabilities: 0x0
  reason: unknown
  negotiated physical link rate: phy enabled, 6 Gbps
  optical mode enabled: 0
  negotiated SSC: 0
  hardware muxing supported: 0
  default inside ZPSDS persistent: 0
  default requested inside ZPSDS: 0
  default zone group persistent: 1
  default zoning enabled: 0
  default zone group: 1
  saved inside ZPSDS persistent: 0
  saved requested inside ZPSDS: 0
  saved zone group persistent: 1
  saved zoning enabled: 0
  saved zone group: 1
  shadow inside ZPSDS persistent: 0
  shadow requested inside ZPSDS: 0
  shadow zone group persistent: 1
  shadow zoning enabled: 0
  shadow zone group: 1
  device slot number: 255
  device slot group number: 255
  device slot group output connector:      =20
Discover response:
  expander change count: 241
  phy identifier: 24
  attached device type: no device attached
  attached reason: unknown
  negotiated logical link rate: phy disabled
  attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0
  attached sata port selector: 0
  STP buffer too small: 0
  attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D0
  SAS address: 0x50030480017bd5bf
  attached SAS address: 0x0
  attached phy identifier: 0
  attached persistent capable: 0
  attached power capable: 0
  attached slumber capable: 0
  attached partial capable: 0
  attached inside ZPSDS persistent: 0
  attached requested inside ZPSDS: 0
  attached break_reply capable: 0
  attached pwr_dis capable: 0
  programmed minimum physical link rate: 1.5 Gbps
  hardware minimum physical link rate: 1.5 Gbps
  programmed maximum physical link rate: 6 Gbps
  hardware maximum physical link rate: 6 Gbps
  phy change count: 1
  virtual phy: 0
  partial pathway timeout value: 7 us
  routing attribute: direct
  connector type: No information
  connector element index: 0
  connector physical link: 0
  phy power condition: 0
  sas power capable: 0
  sas slumber capable: 0
  sas partial capable: 0
  sata slumber capable: 0
  sata partial capable: 0
  pwr_dis signal: 0
  pwr_dis control capable: 0
  sas slumber enabled: 0
  sas partial enabled: 0
  sata slumber enabled: 0
  sata partial enabled: 0
  attached device name: 0x0
  requested inside ZPSDS changed by expander: 0
  inside ZPSDS persistent: 0
  requested inside ZPSDS: 0
  zone group persistent: 1
  inside ZPSDS: 0
  zoning enabled: 0
  zone group: 1
  self-configuration status: 0
  self-configuration levels completed: 0
  self-configuration sas address: 0x0
  programmed phy capabilities: 0x0
  current phy capabilities: 0x0
  attached phy capabilities: 0x0
  reason: unknown
  negotiated physical link rate: phy disabled
  optical mode enabled: 0
  negotiated SSC: 0
  hardware muxing supported: 0
  default inside ZPSDS persistent: 0
  default requested inside ZPSDS: 0
  default zone group persistent: 1
  default zoning enabled: 0
  default zone group: 1
  saved inside ZPSDS persistent: 0
  saved requested inside ZPSDS: 0
  saved zone group persistent: 1
  saved zoning enabled: 0
  saved zone group: 1
  shadow inside ZPSDS persistent: 0
  shadow requested inside ZPSDS: 0
  shadow zone group persistent: 1
  shadow zoning enabled: 0
  shadow zone group: 1
  device slot number: 255
  device slot group number: 255
  device slot group output connector:      =20
Discover response:
  expander change count: 241
  phy identifier: 25
  attached device type: no device attached
  attached reason: unknown
  negotiated logical link rate: phy disabled
  attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0
  attached sata port selector: 0
  STP buffer too small: 0
  attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D0
  SAS address: 0x50030480017bd5bf
  attached SAS address: 0x0
  attached phy identifier: 0
  attached persistent capable: 0
  attached power capable: 0
  attached slumber capable: 0
  attached partial capable: 0
  attached inside ZPSDS persistent: 0
  attached requested inside ZPSDS: 0
  attached break_reply capable: 0
  attached pwr_dis capable: 0
  programmed minimum physical link rate: 1.5 Gbps
  hardware minimum physical link rate: 1.5 Gbps
  programmed maximum physical link rate: 6 Gbps
  hardware maximum physical link rate: 6 Gbps
  phy change count: 1
  virtual phy: 0
  partial pathway timeout value: 7 us
  routing attribute: direct
  connector type: No information
  connector element index: 0
  connector physical link: 0
  phy power condition: 0
  sas power capable: 0
  sas slumber capable: 0
  sas partial capable: 0
  sata slumber capable: 0
  sata partial capable: 0
  pwr_dis signal: 0
  pwr_dis control capable: 0
  sas slumber enabled: 0
  sas partial enabled: 0
  sata slumber enabled: 0
  sata partial enabled: 0
  attached device name: 0x0
  requested inside ZPSDS changed by expander: 0
  inside ZPSDS persistent: 0
  requested inside ZPSDS: 0
  zone group persistent: 1
  inside ZPSDS: 0
  zoning enabled: 0
  zone group: 1
  self-configuration status: 0
  self-configuration levels completed: 0
  self-configuration sas address: 0x0
  programmed phy capabilities: 0x0
  current phy capabilities: 0x0
  attached phy capabilities: 0x0
  reason: unknown
  negotiated physical link rate: phy disabled
  optical mode enabled: 0
  negotiated SSC: 0
  hardware muxing supported: 0
  default inside ZPSDS persistent: 0
  default requested inside ZPSDS: 0
  default zone group persistent: 1
  default zoning enabled: 0
  default zone group: 1
  saved inside ZPSDS persistent: 0
  saved requested inside ZPSDS: 0
  saved zone group persistent: 1
  saved zoning enabled: 0
  saved zone group: 1
  shadow inside ZPSDS persistent: 0
  shadow requested inside ZPSDS: 0
  shadow zone group persistent: 1
  shadow zoning enabled: 0
  shadow zone group: 1
  device slot number: 255
  device slot group number: 255
  device slot group output connector:      =20
Discover response:
  expander change count: 241
  phy identifier: 26
  attached device type: no device attached
  attached reason: unknown
  negotiated logical link rate: phy disabled
  attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0
  attached sata port selector: 0
  STP buffer too small: 0
  attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D0
  SAS address: 0x50030480017bd5bf
  attached SAS address: 0x0
  attached phy identifier: 0
  attached persistent capable: 0
  attached power capable: 0
  attached slumber capable: 0
  attached partial capable: 0
  attached inside ZPSDS persistent: 0
  attached requested inside ZPSDS: 0
  attached break_reply capable: 0
  attached pwr_dis capable: 0
  programmed minimum physical link rate: 1.5 Gbps
  hardware minimum physical link rate: 1.5 Gbps
  programmed maximum physical link rate: 6 Gbps
  hardware maximum physical link rate: 6 Gbps
  phy change count: 1
  virtual phy: 0
  partial pathway timeout value: 7 us
  routing attribute: direct
  connector type: No information
  connector element index: 0
  connector physical link: 0
  phy power condition: 0
  sas power capable: 0
  sas slumber capable: 0
  sas partial capable: 0
  sata slumber capable: 0
  sata partial capable: 0
  pwr_dis signal: 0
  pwr_dis control capable: 0
  sas slumber enabled: 0
  sas partial enabled: 0
  sata slumber enabled: 0
  sata partial enabled: 0
  attached device name: 0x0
  requested inside ZPSDS changed by expander: 0
  inside ZPSDS persistent: 0
  requested inside ZPSDS: 0
  zone group persistent: 1
  inside ZPSDS: 0
  zoning enabled: 0
  zone group: 1
  self-configuration status: 0
  self-configuration levels completed: 0
  self-configuration sas address: 0x0
  programmed phy capabilities: 0x0
  current phy capabilities: 0x0
  attached phy capabilities: 0x0
  reason: unknown
  negotiated physical link rate: phy disabled
  optical mode enabled: 0
  negotiated SSC: 0
  hardware muxing supported: 0
  default inside ZPSDS persistent: 0
  default requested inside ZPSDS: 0
  default zone group persistent: 1
  default zoning enabled: 0
  default zone group: 1
  saved inside ZPSDS persistent: 0
  saved requested inside ZPSDS: 0
  saved zone group persistent: 1
  saved zoning enabled: 0
  saved zone group: 1
  shadow inside ZPSDS persistent: 0
  shadow requested inside ZPSDS: 0
  shadow zone group persistent: 1
  shadow zoning enabled: 0
  shadow zone group: 1
  device slot number: 255
  device slot group number: 255
  device slot group output connector:      =20
Discover response:
  expander change count: 241
  phy identifier: 27
  attached device type: no device attached
  attached reason: unknown
  negotiated logical link rate: phy disabled
  attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0
  attached sata port selector: 0
  STP buffer too small: 0
  attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D0
  SAS address: 0x50030480017bd5bf
  attached SAS address: 0x0
  attached phy identifier: 0
  attached persistent capable: 0
  attached power capable: 0
  attached slumber capable: 0
  attached partial capable: 0
  attached inside ZPSDS persistent: 0
  attached requested inside ZPSDS: 0
  attached break_reply capable: 0
  attached pwr_dis capable: 0
  programmed minimum physical link rate: 1.5 Gbps
  hardware minimum physical link rate: 1.5 Gbps
  programmed maximum physical link rate: 6 Gbps
  hardware maximum physical link rate: 6 Gbps
  phy change count: 1
  virtual phy: 0
  partial pathway timeout value: 7 us
  routing attribute: direct
  connector type: No information
  connector element index: 0
  connector physical link: 0
  phy power condition: 0
  sas power capable: 0
  sas slumber capable: 0
  sas partial capable: 0
  sata slumber capable: 0
  sata partial capable: 0
  pwr_dis signal: 0
  pwr_dis control capable: 0
  sas slumber enabled: 0
  sas partial enabled: 0
  sata slumber enabled: 0
  sata partial enabled: 0
  attached device name: 0x0
  requested inside ZPSDS changed by expander: 0
  inside ZPSDS persistent: 0
  requested inside ZPSDS: 0
  zone group persistent: 1
  inside ZPSDS: 0
  zoning enabled: 0
  zone group: 1
  self-configuration status: 0
  self-configuration levels completed: 0
  self-configuration sas address: 0x0
  programmed phy capabilities: 0x0
  current phy capabilities: 0x0
  attached phy capabilities: 0x0
  reason: unknown
  negotiated physical link rate: phy disabled
  optical mode enabled: 0
  negotiated SSC: 0
  hardware muxing supported: 0
  default inside ZPSDS persistent: 0
  default requested inside ZPSDS: 0
  default zone group persistent: 1
  default zoning enabled: 0
  default zone group: 1
  saved inside ZPSDS persistent: 0
  saved requested inside ZPSDS: 0
  saved zone group persistent: 1
  saved zoning enabled: 0
  saved zone group: 1
  shadow inside ZPSDS persistent: 0
  shadow requested inside ZPSDS: 0
  shadow zone group persistent: 1
  shadow zoning enabled: 0
  shadow zone group: 1
  device slot number: 255
  device slot group number: 255
  device slot group output connector:      =20
Discover response:
  expander change count: 241
  phy identifier: 28
  attached device type: SAS or SATA device
  attached reason: unknown
  negotiated logical link rate: phy enabled, 6 Gbps
  attached initiator: ssp=3D1 stp=3D0 smp=3D1 sata_host=3D0
  attached sata port selector: 0
  STP buffer too small: 0
  attached target: ssp=3D1 stp=3D0 smp=3D0 sata_device=3D0
  SAS address: 0x50030480017bd5bf
  attached SAS address: 0x50030480017bd5bd
  attached phy identifier: 0
  attached persistent capable: 0
  attached power capable: 0
  attached slumber capable: 0
  attached partial capable: 0
  attached inside ZPSDS persistent: 0
  attached requested inside ZPSDS: 0
  attached break_reply capable: 0
  attached pwr_dis capable: 0
  programmed minimum physical link rate: 6 Gbps
  hardware minimum physical link rate: 6 Gbps
  programmed maximum physical link rate: 6 Gbps
  hardware maximum physical link rate: 6 Gbps
  phy change count: 1
  virtual phy: 1
  partial pathway timeout value: 7 us
  routing attribute: direct
  connector type: No information
  connector element index: 0
  connector physical link: 0
  phy power condition: 0
  sas power capable: 0
  sas slumber capable: 0
  sas partial capable: 0
  sata slumber capable: 0
  sata partial capable: 0
  pwr_dis signal: 0
  pwr_dis control capable: 0
  sas slumber enabled: 0
  sas partial enabled: 0
  sata slumber enabled: 0
  sata partial enabled: 0
  attached device name: 0x0
  requested inside ZPSDS changed by expander: 0
  inside ZPSDS persistent: 0
  requested inside ZPSDS: 0
  zone group persistent: 1
  inside ZPSDS: 1
  zoning enabled: 0
  zone group: 1
  self-configuration status: 0
  self-configuration levels completed: 0
  self-configuration sas address: 0x0
  programmed phy capabilities: 0x0
  current phy capabilities: 0x0
  attached phy capabilities: 0x0
  reason: unknown
  negotiated physical link rate: phy enabled, 6 Gbps
  optical mode enabled: 0
  negotiated SSC: 0
  hardware muxing supported: 0
  default inside ZPSDS persistent: 0
  default requested inside ZPSDS: 0
  default zone group persistent: 1
  default zoning enabled: 0
  default zone group: 1
  saved inside ZPSDS persistent: 0
  saved requested inside ZPSDS: 0
  saved zone group persistent: 1
  saved zoning enabled: 0
  saved zone group: 1
  shadow inside ZPSDS persistent: 0
  shadow requested inside ZPSDS: 0
  shadow zone group persistent: 1
  shadow zoning enabled: 0
  shadow zone group: 1
  device slot number: 255
  device slot group number: 255
  device slot group output connector:      =20
root@rhea:~ #=20


On Dec 5, 2014, at 5:05 PM, Alan Somers <asomers@freebsd.org> wrote:

> I had a very similar problem that ended up being a bug in the expander
> firmware.  It was exposed by the mpr(4) driver because that driver
> enumerates drives differently than mps(4) or Linux.  Please install
> sysutils.smp_utils and post the output of "smp_discover -p $PHY $DEV"
> where $DEV is each expander (probably ses0 and ses1) and $PHY is every
> phy on each expander.  You can see the list of phys by doing
> "smp_discover $DEV" without the "-p" option.  Also, would you mind
> running "sg_inq --hex --len=3D64 $DEV" so I know what we're working
> with?
>=20
> -Alan
>=20




Want to link to this message? Use this URL: <https://mail-archive.FreeBSD.org/cgi/mid.cgi?DD7EC4AD-A4B6-46F7-8F1C-9AD111DF20C6>