Skip site navigation (1)Skip section navigation (2)
Date:      Thu, 22 Dec 2005 13:30:27 +0300
From:      Gleb Smirnoff <glebius@FreeBSD.org>
To:        Danny Braniss <danny@cs.huji.ac.il>
Cc:        freebsd-stable@FreeBSD.org
Subject:   Re: em bad performance
Message-ID:  <20051222103027.GZ41381@cell.sick.ru>
In-Reply-To: <E1EpNco-000HuT-VQ@cs1.cs.huji.ac.il>
References:  <20051222095240.GX41381@FreeBSD.org> <E1EpNco-000HuT-VQ@cs1.cs.huji.ac.il>

next in thread | previous in thread | raw e-mail | index | archive | help
On Thu, Dec 22, 2005 at 12:24:42PM +0200, Danny Braniss wrote:
D> ------------------------------------------------------------
D> Server listening on TCP port 5001
D> TCP window size: 64.0 KByte (default)
D> ------------------------------------------------------------
D> [  4] local 132.65.16.100 port 5001 connected with [6.0/SE7501WV2] port 58122 
D> (intel westvill)
D> [ ID] Interval       Transfer     Bandwidth
D> [  4]  0.0-10.0 sec  1.01 GBytes   867 Mbits/sec
D> [  4] local 132.65.16.100 port 5001 connected with [5.4/SE7501WV2] port 55269 
D> (intel westvill)
D> [ ID] Interval       Transfer     Bandwidth
D> [  4]  0.0-10.0 sec   967 MBytes   811 Mbits/sec
D> [  5] local 132.65.16.100 port 5001 connected with [6.0/SR1435VP2 port 58363  
D> (intel dual xeon/emt64)
D> [ ID] Interval       Transfer     Bandwidth
D> [  5]  0.0-10.0 sec   578 MBytes   485 Mbits/sec
D> 
D> i've run this several times, and the results are very similar.
D> i also tried i386, and the same bad results.
D> all hosts are connected at 1gb to the same switch.

So we see a strong drawback between SE7501WV2 and SR1435VP2. Let's compare the NIC
hardware. Can you plese show pciconf -lv | grep -A3 ^em on both motherboards?

-- 
Totus tuus, Glebius.
GLEBIUS-RIPN GLEB-RIPE



Want to link to this message? Use this URL: <https://mail-archive.FreeBSD.org/cgi/mid.cgi?20051222103027.GZ41381>