Skip site navigation (1)Skip section navigation (2)
Date:      Fri, 22 Aug 2008 16:28:32 -0700
From:      Randy Bush <randy@psg.com>
To:        freebsd-fs@freebsd.org
Subject:   zfs bringing a new drive online
Message-ID:  <48AF4BA0.5040208@psg.com>

next in thread | raw e-mail | index | archive | help
one of the drives in my pool got funky.  i put it offline

2008-07-26.16:23:44 zpool offline -t tank ad6s1
2008-07-26.16:24:28 zpool offline tank ad6s1

and then replaced it.  i rebooted so the hw and driver would be happy
about the drive, and then

# zpool online tank ad6s1
Bringing device ad6s1 online

# zpool status -x
  pool: tank
 state: DEGRADED
status: One or more devices could not be opened.  Sufficient replicas
exist for
        the pool to continue functioning in a degraded state.
action: Attach the missing device and online it using 'zpool online'.
   see: http://www.sun.com/msg/ZFS-8000-D3
 scrub: resilver completed with 0 errors on Fri Aug 22 23:14:44 2008
config:

        NAME        STATE     READ WRITE CKSUM
        tank        DEGRADED     0     0     0
          raidz1    DEGRADED     0     0     0
            ad4s2   ONLINE       0     0     0
            ad8s2   ONLINE       0     0     0
            ad6s1   UNAVAIL      0     0     0  cannot open
            ad10s1  ONLINE       0     0     0

errors: No known data errors

smartctl seems to like the spindle

# smartctl -a /dev/ad6
smartctl version 5.38 [amd64-portbld-freebsd8.0] Copyright (C) 2002-8
Bruce Allen
Home page is http://smartmontools.sourceforge.net/

=== START OF INFORMATION SECTION ===
Model Family:     Seagate Barracuda 7200.10 family
Device Model:     ST3320620AS
Serial Number:    6QF3RPZC
Firmware Version: 3.AAE
User Capacity:    320,072,933,376 bytes
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   7
ATA Standard is:  Exact ATA specification draft version not indicated
Local Time is:    Fri Aug 22 23:25:37 2008 UTC
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x82) Offline data collection activity
                                        was completed without error.
                                        Auto Offline Data Collection:
Enabled.
Self-test execution status:      (   0) The previous self-test routine
completed
                                        without error or no self-test
has ever
                                        been run.
Total time to complete Offline
data collection:                 ( 430) seconds.
Offline data collection
capabilities:                    (0x5b) SMART execute Offline immediate.
                                        Auto Offline data collection
on/off support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        No Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine
recommended polling time:        (   1) minutes.
Extended self-test routine
recommended polling time:        ( 115) minutes.

SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE
UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000f   105   100   006    Pre-fail  Always
      -       145017563
  3 Spin_Up_Time            0x0003   099   099   000    Pre-fail  Always
      -       0
  4 Start_Stop_Count        0x0032   100   100   020    Old_age   Always
      -       1
  5 Reallocated_Sector_Ct   0x0033   100   100   036    Pre-fail  Always
      -       0
  7 Seek_Error_Rate         0x000f   100   253   030    Pre-fail  Always
      -       279592
  9 Power_On_Hours          0x0032   100   100   000    Old_age   Always
      -       4
 10 Spin_Retry_Count        0x0013   100   100   097    Pre-fail  Always
      -       0
 12 Power_Cycle_Count       0x0032   100   100   020    Old_age   Always
      -       3
187 Reported_Uncorrect      0x0032   100   100   000    Old_age   Always
      -       0
189 High_Fly_Writes         0x003a   100   100   000    Old_age   Always
      -       0
190 Airflow_Temperature_Cel 0x0022   054   054   045    Old_age   Always
      -       46 (Lifetime Min/Max 37/46)
194 Temperature_Celsius     0x0022   046   046   000    Old_age   Always
      -       46 (0 37 0 0)
195 Hardware_ECC_Recovered  0x001a   063   060   000    Old_age   Always
      -       159460935
197 Current_Pending_Sector  0x0012   100   100   000    Old_age   Always
      -       0
198 Offline_Uncorrectable   0x0010   100   100   000    Old_age
Offline      -       0
199 UDMA_CRC_Error_Count    0x003e   200   253   000    Old_age   Always
      -       0
200 Multi_Zone_Error_Rate   0x0000   100   253   000    Old_age
Offline      -       0
202 TA_Increase_Count       0x0032   100   253   000    Old_age   Always
      -       0

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining
LifeTime(hours)  LBA_of_first_error
# 1  Short offline       Completed without error       00%         4
     -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

clearly, i am not understanding something

randy