Date: Fri, 22 Aug 2008 16:28:32 -0700 From: Randy Bush <randy@psg.com> To: freebsd-fs@freebsd.org Subject: zfs bringing a new drive online Message-ID: <48AF4BA0.5040208@psg.com>
next in thread | raw e-mail | index | archive | help
one of the drives in my pool got funky. i put it offline 2008-07-26.16:23:44 zpool offline -t tank ad6s1 2008-07-26.16:24:28 zpool offline tank ad6s1 and then replaced it. i rebooted so the hw and driver would be happy about the drive, and then # zpool online tank ad6s1 Bringing device ad6s1 online # zpool status -x pool: tank state: DEGRADED status: One or more devices could not be opened. Sufficient replicas exist for the pool to continue functioning in a degraded state. action: Attach the missing device and online it using 'zpool online'. see: http://www.sun.com/msg/ZFS-8000-D3 scrub: resilver completed with 0 errors on Fri Aug 22 23:14:44 2008 config: NAME STATE READ WRITE CKSUM tank DEGRADED 0 0 0 raidz1 DEGRADED 0 0 0 ad4s2 ONLINE 0 0 0 ad8s2 ONLINE 0 0 0 ad6s1 UNAVAIL 0 0 0 cannot open ad10s1 ONLINE 0 0 0 errors: No known data errors smartctl seems to like the spindle # smartctl -a /dev/ad6 smartctl version 5.38 [amd64-portbld-freebsd8.0] Copyright (C) 2002-8 Bruce Allen Home page is http://smartmontools.sourceforge.net/ === START OF INFORMATION SECTION === Model Family: Seagate Barracuda 7200.10 family Device Model: ST3320620AS Serial Number: 6QF3RPZC Firmware Version: 3.AAE User Capacity: 320,072,933,376 bytes Device is: In smartctl database [for details use: -P show] ATA Version is: 7 ATA Standard is: Exact ATA specification draft version not indicated Local Time is: Fri Aug 22 23:25:37 2008 UTC SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 430) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 115) minutes. SMART Attributes Data Structure revision number: 10 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 105 100 006 Pre-fail Always - 145017563 3 Spin_Up_Time 0x0003 099 099 000 Pre-fail Always - 0 4 Start_Stop_Count 0x0032 100 100 020 Old_age Always - 1 5 Reallocated_Sector_Ct 0x0033 100 100 036 Pre-fail Always - 0 7 Seek_Error_Rate 0x000f 100 253 030 Pre-fail Always - 279592 9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 4 10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0 12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 3 187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0 189 High_Fly_Writes 0x003a 100 100 000 Old_age Always - 0 190 Airflow_Temperature_Cel 0x0022 054 054 045 Old_age Always - 46 (Lifetime Min/Max 37/46) 194 Temperature_Celsius 0x0022 046 046 000 Old_age Always - 46 (0 37 0 0) 195 Hardware_ECC_Recovered 0x001a 063 060 000 Old_age Always - 159460935 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x003e 200 253 000 Old_age Always - 0 200 Multi_Zone_Error_Rate 0x0000 100 253 000 Old_age Offline - 0 202 TA_Increase_Count 0x0032 100 253 000 Old_age Always - 0 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 4 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. clearly, i am not understanding something randy
Want to link to this message? Use this URL: <https://mail-archive.FreeBSD.org/cgi/mid.cgi?48AF4BA0.5040208>