Skip site navigation (1)Skip section navigation (2)
Date:      Fri, 01 May 1998 18:06:18 +1000
From:      Hugh Blandford <hugh@island.net.au>
To:        questions@FreeBSD.ORG
Subject:   UPSd & APC with ShareUPS
Message-ID:  <3.0.1.32.19980501180618.006d156c@mail.island.net.au>
In-Reply-To: <862565F6.00577442.00@platinum.com>

next in thread | previous in thread | raw e-mail | index | archive | help
Hi all,

I have an APC SmartUPS 3000 and a ShareUPS.  I have a NT box currently
plugged into the master port on the ShareUPS running Powerchute.  This box
doesn't run 24x7 unlike the FreeBSD boxes ;)  Anyway I have been trying to
get the UPSd from the ports collection to run on the FreeBSD machines.

I have tried a cable as per the spec on
http://www.cre8tivegroup.com/upsd.html and the APC cable and none seem to
work with my configuration.  I have tried using the upsd.conf.sample file,
renamed as the configuration file and it says that it cannot switch to
smart mode.  I have also tried the default config and it says that it fails
the self-test.  

Can someone please enlighten me and if possible send me a .conf that works
(privately :) for 240V?  Is the 3 wire cable all I need as per the above
URL or should I be running with a cable configured exactly the same as the
APC one?

On another note I've set up the ShareUPS so that it runs till 2 min warning
and then it shuts down the UPS so it cycles the power on startup.  Is there
a way to set up the .conf to make an impossibly large wait for the shutdown
time and when the daemon receives the 2 min warning triggers a shutdown.

Thanks for the help.

Hugh

To Unsubscribe: send mail to majordomo@FreeBSD.org
with "unsubscribe freebsd-questions" in the body of the message



Want to link to this message? Use this URL: <https://mail-archive.FreeBSD.org/cgi/mid.cgi?3.0.1.32.19980501180618.006d156c>