Skip site navigation (1)Skip section navigation (2)
Date:      Mon, 27 May 2002 22:46:07 +0300
From:      Vallo Kallaste <kalts@estpak.ee>
To:        David J Duchscher <daved@nostrum.com>
Cc:        freebsd-stable@FreeBSD.ORG
Subject:   Re: Hardware RAID vs vinum
Message-ID:  <20020527194607.GA14628@myhakas.estpak.ee>
In-Reply-To: <B2649056-71A6-11D6-96E4-00306547FB28@nostrum.com>
References:  <20020527084348.GA9774@myhakas.estpak.ee> <B2649056-71A6-11D6-96E4-00306547FB28@nostrum.com>

next in thread | previous in thread | raw e-mail | index | archive | help
On Mon, May 27, 2002 at 02:19:42PM -0500, David J Duchscher <daved@nostrum.com> wrote:

> >Have you had dying disk in your vinum R5 configuration? If yes can
> >you please tell me how you rebuilt new disk? I have had no luck
> >rebuilding failed disk while filesystem on the degraded array is
> >mounted and user I/O going on. The disk will be rebuilt and
> >filesystem will be corrupted. I'm able to reproduce it at will with
> >either SCSI or ATA disks, no matter on what system I try it.
> 
> Have you tried these instructions:
> 
>   http://www.vinumvm.org/vinum/replacing-drive.html

Yes I'm aware of these, no I'm not in need of them because of
failure simulation only. While testing (simulating) replace and
rebuild of failed drive there's no need to physically remove nor
repartition disk. You'll place load on filesystem residing on R5
array, then simply force stop (stop -f) one subdisk. After a while
running in degraded mode will simply start the subdisk again and
reviving process starts. At the end you can be sure that newfs and
restore of data is in order. Haven't had any other experience.
Smells like FUD but isn't.
-- 

Vallo Kallaste
kalts@estpak.ee

To Unsubscribe: send mail to majordomo@FreeBSD.org
with "unsubscribe freebsd-stable" in the body of the message




Want to link to this message? Use this URL: <https://mail-archive.FreeBSD.org/cgi/mid.cgi?20020527194607.GA14628>