Skip site navigation (1)Skip section navigation (2)
Date:      Wed, 10 Mar 2010 13:08:42 -0600
From:      Kevin Day <toasty@dragondata.com>
To:        Kostik Belousov <kostikbel@gmail.com>
Cc:        freebsd-hackers@freebsd.org
Subject:   Re: Extremely slow boot on VMWare with Opteron 2352 (acpi?)
Message-ID:  <F2B3958F-FC4B-422B-BDA7-3185C8931447@dragondata.com>
In-Reply-To: <20100310112753.GW2489@deviant.kiev.zoral.com.ua>
References:  <2C7A849F-2571-48E7-AA75-B6F87C2352C1@dragondata.com> <201003091727.09188.jhb@freebsd.org> <207B4180-B8AF-4C93-8BC7-7F1FFEEBB713@dragondata.com> <20100310112753.GW2489@deviant.kiev.zoral.com.ua>

next in thread | previous in thread | raw e-mail | index | archive | help

On Mar 10, 2010, at 5:27 AM, Kostik Belousov wrote:
> I think that the idea not to for CLFLUSH in the loop for large regions
> is good. We do not extract the L2/L3 cache size now, I suppose that =
2MB
> estimation is good for most situations.
>=20
> commit bbac1632d349d68b905df644656ce9a8e4aed094


Thanks for everyone's help. This has actually increased the boot up =
speed of all of our Opteron based boxes through VMware ESX. I'll report =
the problem to VMware, but I'm betting this is a side effect of the =
CLFLUSH problems in virtualized Opteron machines that they worked around =
with a much slower function.

-- Kevin
=20=



Want to link to this message? Use this URL: <https://mail-archive.FreeBSD.org/cgi/mid.cgi?F2B3958F-FC4B-422B-BDA7-3185C8931447>