Skip site navigation (1)Skip section navigation (2)
Date:      Fri, 20 Feb 2004 09:22:21 +1100
From:      Tony Frank <tfrank@optushome.com.au>
To:        Danny Carroll <danny@dannysplace.net>
Cc:        freebsd-questions@freebsd.org
Subject:   Re: Help with Vinum disk crash...
Message-ID:  <20040219222221.GA88317@marvin.home.local>
In-Reply-To: <1077180395.4prky8v4skqo@mailsrv.dannysplace.net>
References:  <00ed01c3f559$d7f1ac20$8052260a@capgemini.nl> <20040217223827.GM33797@wantadilla.lemis.com> <1077093269.15aypd5fp76s@mailsrv.dannysplace.net> <20040218111653.GB289@marvin.home.local> <1077106518.yyrhxqeampw@mailsrv.dannysplace.net> <20040218140429.GG289@marvin.home.local> <1077180395.4prky8v4skqo@mailsrv.dannysplace.net>

next in thread | previous in thread | raw e-mail | index | archive | help
Hi,

On Thu, Feb 19, 2004 at 09:46:35AM +0100, Danny Carroll wrote:
> Thanks for the information...  I really need the space now so I am going to wipe
> it and start from scratch, although I am not sure if I will use vinum again.
> 
> I guess my main concern is that when one of my disks crashed, the ufs filesystem
> got corrupted and I really did not expect that to happen.
> 
> It could be ignorance on my part, I dont know but perhaps someone can help me
> understand how this could have happened?

Filesystems can get corrupted if the system crashes and does not cleanly close the
filesystem first.
In your case I'm personally not too sure - some more questions perhaps can help.

- Were you using softupdates on the filesystem?
- Did the system panic/reboot when the disk crashed without shutting down cleanly?
- What version of FreeBSD are you / were you running?

> Another thing, Greg, you mentioned that I should have a second plex if I wanted
> to protect the data.  You mean like a mirror?  Surely 1 is enough when we are
> talking raid-5?

Raid-5 should still work if a single subdisk fails.  
In your original post you did not indicate if you were using raid5 setup.

If you had configured the subdisks as a concatenated or striped plex then there
would most likely be no way to continue with a disk missing unless there existed
a second plex with a copy of the data.

Regards,

Tony