Hi,

My IBM System x3250 M5 has IPMI. It shares onboard NIC Broadcom BCM5719.
I'm setup it and IPMI works perfectly.
But when server boots in single user mode IPMI's IP becomes unreachable.
It occures when bge0 init.

Any hints?

Thanks.


Details are:

FreeBSD 10.1-STABLE (r274690) amd64

/boot/loader.conf
hw.bge.allow_asf=1


bge0: <Broadcom NetXtreme Gigabit Ethernet Controller, ASIC rev.
0x5719001> mem
0x82a50000-0x82a5ffff,0x82a40000-0x82a4ffff,0x82a30000-0x82a3ffff irq 16
at device 0.0 on pci6
bge0: APE FW version: NCSI v1.2.33.0
bge0: CHIP ID 0x05719001; ASIC REV 0x5719; CHIP REV 0x57190; PCI-E
miibus0: <MII bus> on bge0
brgphy0: <BCM5719C 1000BASE-T media interface> PHY 1 on miibus0
brgphy0:  10baseT, 10baseT-FDX, 100baseTX, 100baseTX-FDX, 1000baseT,
1000baseT-master, 1000baseT-FDX, 1000baseT-FDX-master, auto, auto-flow
bge0: Using defaults for TSO: 65518/35/2048
bge0: Ethernet address: 6c:ae:8b:5b:74:98


bge0@pci0:6:0:0:        class=0x020000 card=0x04911014 chip=0x165714e4
rev=0x01 hdr=0x00
    vendor     = 'Broadcom Corporation'
    device     = 'NetXtreme BCM5719 Gigabit Ethernet PCIe'
    class      = network
    subclass   = ethernet
    bar   [10] = type Prefetchable Memory, range 64, base 0x82a50000,
size 65536, enabled
    bar   [18] = type Prefetchable Memory, range 64, base 0x82a40000,
size 65536, enabled
    bar   [20] = type Prefetchable Memory, range 64, base 0x82a30000,
size 65536, enabled
    cap 01[48] = powerspec 3  supports D0 D3  current D0
    cap 03[50] = VPD
    cap 05[58] = MSI supports 8 messages, 64 bit enabled with 1 message
    cap 11[a0] = MSI-X supports 17 messages
                 Table in map 0x20[0x0], PBA in map 0x20[0x1000]
    cap 10[ac] = PCI-Express 2 endpoint max data 128(256) FLR link x2(x4)
                 speed 5.0(5.0) ASPM disabled(L0s/L1)
    ecap 0001[100] = AER 1 0 fatal 0 non-fatal 1 corrected
    ecap 0003[13c] = Serial 1 00006cae8b5b7498
    ecap 0004[150] = Power Budgeting 1
    ecap 0002[160] = VC 1 max VC0


-- 