References:  <CAPYfQ9z-YUzKDAh3=V3_m1wmDtds4NzcewTq0wLUD9LWt3VaGA@mail.gmail.com> <20140316130936.3f2d18e0@X220.alogt.com> <CAPYfQ9ycxEr%2B-qPBC6qY6tvLrTMqT3guU%2B8q%2BbK2_RAj=WH1tw@mail.gmail.com> <20140316134309.2edc258a@X220.alogt.com> <CAPYfQ9ztmzYWSRoNLJk2Z-mTAdDti48ZOJrKT0LEEpuWf5SqHg@mail.gmail.com>

next in thread | previous in thread | raw e-mail | index | archive | help
On Sun, 16 Mar 2014, cruxpot wrote:

> Back in December, it was the power supply. That was a cheap Rosewill
> 300W PSU. The new is a Corsair CX500 (500W). The system basically just
> has an old SCSI card and 4 Green Barracuda 2TB disks and a low end
> pci-e video card and pci-e gigabit NIC. How can the PSU be the problem
> since I replaced it and it's more than adequate?

Those SMART numbers are not necessarily a problem.  Seagate reports them 
differently than other vendors.  I've found used Seagate drives with 
similar ridiculous numbers, but searches found that it was a normal 
Seagate thing, and the drives have continued to work normally.  For 
example, in 8191 operating hours, a Seagate Momentus drive reports a
Raw_Read_Error_Rate of 1,946,347,38 and a Seek_Error_Rate of 
110,829,183.

The counts to really watch are Reallocated_Sector_Ct and 
Current_Pending_Sector.