Skip site navigation (1)Skip section navigation (2)
Date:      Wed, 2 Jul 2008 09:55:09 +0200
From:      Marian Hettwer <mh@kernel32.de>
To:        ulf@Alameda.net
Cc:        Jo Rhett <jrhett@netconsonance.com>, freebsd-stable@freebsd.org
Subject:   Re: no serial console for ttyd0 HP Blade
Message-ID:  <b6cd88e60d6565f3a6529c2684f75c6a@localhost>
In-Reply-To: <20080702063651.GD69034@evil.alameda.net>
References:  <20080702063651.GD69034@evil.alameda.net>

next in thread | previous in thread | raw e-mail | index | archive | help
Hi there,

On Tue, 1 Jul 2008 23:36:51 -0700, Ulf Zimmermann <ulf@Alameda.net> wrote:
> Also remember that the blades have 2 serial ports, one can be accessed
via
> a dongle in the front of the blade and I believe that is what usual would
> be
> called COM1 by default. The virtual serial via ilo takes up the COM2 by
> default. This is at least the default on DL series servers and I haven't
> checked into using the virtual serial on the Blades we have.
> 
Well, I enabled ttyd1 too in /etc/ttys and gave init a kill -HUP:
[root@db46-202.mobile.rz] <~>ps ax | grep ttyd                         
[9:54:02 on 08-07-02]
 7888  ??  S      0:00.01 /usr/libexec/getty std.9600 ttyd1
  961  d0  Is+    0:00.00 /usr/libexec/getty std.9600 ttyd0

But no login prompt, though...

regards,
Marian