Skip site navigation (1)Skip section navigation (2)
Date:      Sun, 28 Mar 1999 12:33:33 -0500
From:      "RT" <tr49986@rcc.on.ca>
To:        <current@FreeBSD.ORG>
Subject:   3com Nic Problems
Message-ID:  <000101be7941$1b2e3200$2300000a@a35.my.intranet>

next in thread | raw e-mail | index | archive | help
Heres are the nic combinations I've tried in one machine:

3com 905 (at 100mbit) & 3com 905b (at 10mbit)
3com 905b (at 100mbit) & 3com 905 (at 10mbit)
3com 905 (at 100mbit) & realtek 8039 (at 10mbit)
3com 905b (at 100mbit) & realtek (at 10mbit)
3com 905b (at 100mbit) & ne2000 (at 10mbit)

In each case the 3com operating at 100mbit failed to do so smoothly.  In
some cases I receive device time-outs, on bootup "xl0 command not
completed", and in some cases no warning at all..

100mbit will peak at 4MB/s, then all of a sudden stop, then go racing off,
then stop...

This doesn't happen if the 3com cards are operated by themselves.   The
realtek & ne2000 (while slow) perform without these problems.  I believe the
xl? drivers have a problem.

My system is 4-current (updated weekly).  I only starting using 2 nics in
the machine last week. (When I got my cable modem).   The problem occurs
both with and without natd & ipfw.  It also doesn't matter which of the 4
cards is receiving the data (as long as there is only one of them).

Any more information needed?



To Unsubscribe: send mail to majordomo@FreeBSD.org
with "unsubscribe freebsd-current" in the body of the message




Want to link to this message? Use this URL: <https://mail-archive.FreeBSD.org/cgi/mid.cgi?000101be7941$1b2e3200$2300000a>