Skip site navigation (1)Skip section navigation (2)
Date:      Wed, 11 Nov 2009 17:19:52 +0100
From:      Miroslav Lachman <000.fbsd@quip.cz>
To:        Tom Judge <tom@tomjudge.com>
Cc:        David Christensen <davidch@broadcom.com>, "rwilliams@borderware.com" <rwilliams@borderware.com>, Gideon Naim <gideon.naim@broadcom.com>, "net@freebsd.org" <net@freebsd.org>
Subject:   Re: bce(4) BCM5907 CTX write errors on 7.2 driver
Message-ID:  <4AFAE428.5090907@quip.cz>
In-Reply-To: <4AEB2571.7090006@tomjudge.com>
References:  <4AE72910.8090708@tomjudge.com>	<5D267A3F22FD854F8F48B3D2B52381933A04B49180@IRVEXCHCCR01.corp.ad.broadcom.com>	<4AE76FF1.9010401@tomjudge.com>	<5D267A3F22FD854F8F48B3D2B52381933A04B491AE@IRVEXCHCCR01.corp.ad.broadcom.com>	<4AE8CC59.7020004@tomjudge.com>	<4AE9D10F.4040703@tomjudge.com>	<5D267A3F22FD854F8F48B3D2B52381933A054DE883@IRVEXCHCCR01.corp.ad.broadcom.com>	<4AE9F576.4060101@tomjudge.com>	<5D267A3F22FD854F8F48B3D2B52381933A19B35A55@IRVEXCHCCR01.corp.ad.broadcom.com>	<4AEA0B11.2050209@tomjudge.com>	<5D267A3F22FD854F8F48B3D2B52381933A19B35AB0@IRVEXCHCCR01.corp.ad.broadcom.com>	<4AEA1183.7050306@tomjudge.com> <4AEB2571.7090006@tomjudge.com>

next in thread | previous in thread | raw e-mail | index | archive | help
Tom Judge wrote:
> Tom Judge wrote:
>> David Christensen wrote:
>>>>> The next test is to diable the LOM's management firmware
>>>> but boot to
>>>>> an active network.
>
> After disabling the management firmware and doing 1 cold reboot and 3
> warms all worked correctly.
>
> After re enabling the firmware and doing 1 cold reboot and 3 warms, the
> cold works correctly and the warms all failed.
>
> Tom
>>>>> Finally, the routine bce_print_adapter_info() in HEAD
>>>> prints out both
>>>>> the bootcode and management firmware versions. If you can
>>>> get those
>>>>> same changes into your release I'd like to see the versions
>>>> reported
>>>>> on your system.
>>>>>
>>>> Here is the info from a boot of 8.0 RC2.
>>>>
>>>> ASIC: 0x57092003
>>>> B/C: 5.0.6
>>>> Rev: C0
>>>> Bus: PCIe x4, 2.5Gb/s
>>>> Flags: MSI|MFW
>>>> MFW: NCS 2.0.3
>>>>
>>>> And looking at this it seems dells update CD was not up to date
>>>> enough and I only got 5.0.6 firmware not 5.0.9.
>>>
>>> The package version and the bootcode version are similar but
>>> they are not the same. The bootcode you have (v5.0.6) is
>>> sufficient to fix the problem.
>>>
>>
>> Ok just checked in the life cycle manager and it has 5.0.9 installed
>> my bad.
>>
>> Running the other test now.

Hi,
we have two new Dell R610 machines with four bce NICs (only bce0 is 
connected at this time). I tried cold (power cycle in iDRAC) and warm 
reboot (shutdown -r now), NIC is working on every reboot, but I am still 
seeing messages:

bce0: /usr/src/sys/dev/bce/if_bce.c(1525): PHY write timeout!
bce0: /usr/src/sys/dev/bce/if_bce.c(1525): PHY write timeout!
bce0: link state changed to UP

This is on FreeBSD 7.2-RELEASE-p4 amd64

I also see "PHY write timeout" on shutdown time for each NIC.

Other than the log messages, I see no problems with bce NIC, but I have 
not tested it with any high load.

I did not upgraded FW or anything else.

What can I do to help with solving this issue?

Miroslav Lachman



Want to link to this message? Use this URL: <https://mail-archive.FreeBSD.org/cgi/mid.cgi?4AFAE428.5090907>