Skip site navigation (1)Skip section navigation (2)
Date:      Fri, 23 Jun 2006 20:40:30 +0100
From:      "Joao Barros" <joao.barros@gmail.com>
To:        "Alex Franks" <arfranks@gmail.com>
Cc:        freebsd-questions@freebsd.org
Subject:   Re: Hot-Swapping hard drives on Dell PowerEdge 2850 running FBSD 5.5-PRE
Message-ID:  <70e8236f0606231240t77e1b510xd5ecd98c093af559@mail.gmail.com>
In-Reply-To: <2f488c030606231113i2b9b4bdcsa1b4192be54b9011@mail.gmail.com>
References:  <2f488c030606221106q4183de17gbff80d696f704505@mail.gmail.com> <449BAE45.7030705@dial.pipex.com> <2f488c030606231113i2b9b4bdcsa1b4192be54b9011@mail.gmail.com>

next in thread | previous in thread | raw e-mail | index | archive | help
On 6/23/06, Alex Franks <arfranks@gmail.com> wrote:
> The controller is a Perc 4e/Di as assumed, and I'm still a little
> unsure as to whether the 2 drives that shipped with the machine are
> currently set up in a RAID array. The current filesystem is mounted on
> /dev/amrd0s1[a-f] and I would expect to find the new drives named
> similarly after using some useful utility that I'm unaware of. Any
> thoughts?
>
> Thanks again.
> Alex

Try amrstat from ports which will show you something like this:

Logical volume 0        optimal (101.60 GB, RAID5)
Physical drive 0:0      online
Physical drive 0:1      online
Physical drive 1:0      online
Physical drive 1:2      online
Physical drive 1:4      hotspare


-- 
Joao Barros