Skip site navigation (1)Skip section navigation (2)
Date:      Tue, 25 Mar 1997 17:21:46 +0000 (GMT)
From:      Mark Dawson <md@dcs.qmw.ac.uk>
To:        Luigi Rizzo <luigi@labinfo.iet.unipi.it>
Cc:        freebsd-hackers@FreeBSD.org, programmers@dcs.qmw.ac.uk
Subject:   Re: Compaq Smart-2/P RAID controller results
Message-ID:  <YnC0aeO_9JY15SEdJU@dcs.qmw.ac.uk>
In-Reply-To: <199703251425.PAA04749@labinfo.iet.unipi.it>
References:  <199703251425.PAA04749@labinfo.iet.unipi.it>

next in thread | previous in thread | raw e-mail | index | archive | help
> too bad the CCD configuration is not comparable at all with the
> RAID0/RAID5 configuration (actually, it is even slower than my single
> IDE disk!). Would you have a chance of running CCD on the same config as
> H RAID0 ?

You're right, the Wren-VII disks aren't youthful so the comparison is
not fair to the CCD driver.  I've attached the H RAID0 disks to the
ProLiant's integrated NCR 53c875 wide scsi controller and configured
them as a 6 x 4.3GB CCD disk with the following results:

            -------Sequential Output-------- ---Sequential Input-- --Random--
            -Per Char- --Block--- -Rewrite-- -Per Char- --Block--- --Seeks---
Machine  MB K/sec %CPU K/sec %CPU K/sec %CPU K/sec %CPU K/sec %CPU  /sec %CPU
H CCD   300  8491 76.5  8474 19.1  5123 13.7 10273 96.6 12138 16.2 136.8  2.4
H RAID0 300 11615 98.3 15231 36.9  9096 27.1 10532 98.0 16073 30.7 131.6  2.6

Mark