Skip site navigation (1)Skip section navigation (2)
Date:      Tue, 18 Dec 2001 19:58:43 +0100
From:      Massimo Lusetti <massimo@datacode.it>
To:        freebsd-scsi@freebsd.org
Subject:   big mly(4) logical volume
Message-ID:  <1008701923.3c1f91e30fbc2@webapps.datacode.it>

next in thread | raw e-mail | index | archive | help

I've done a fresh 4.4-RELEASE install on-top of a RAID 5 with 5x70G HDD + 1x70G 
hot spare driver over a AcceleRAID 352 controller. 
Just after the kernel take control i notice the hdd's led blink and the never 
stop (at least in the last 8 hours) but i didn't notice any message from the 
driver, well really i've noticed only one message just after the boot process 
ends and i got the login prompt telling me: 

sense data received: 
sense key 11 asc 47 ascq 00 

which i think should per 'aborted command on SCSI parity error' 

Is it normal to have this hdd always busy !? If the controlled is (re)building 
something i should notice on kernel message... right ?! 

Obviously the server is not busy... for now it is disconnected from the 
network. 

Regards, 
Massimo 

To Unsubscribe: send mail to majordomo@FreeBSD.org
with "unsubscribe freebsd-scsi" in the body of the message




Want to link to this message? Use this URL: <https://mail-archive.FreeBSD.org/cgi/mid.cgi?1008701923.3c1f91e30fbc2>