Skip site navigation (1)Skip section navigation (2)
Date:      Fri, 27 Jul 2001 10:34:49 +0200
From:      Bernd Walter <ticso@mail.cicely.de>
To:        Milon Papezik <Milon.Papezik@oskarmobil.cz>
Cc:        Bernd Walter <ticso@mail.cicely.de>, Leo Bicknell <bicknell@ufp.org>, hackers@FreeBSD.ORG
Subject:   Re: ARP cache problems....
Message-ID:  <20010727103449.B4276@cicely20.cicely.de>
In-Reply-To: <B57AF59C8ABFD411BBE000508BF300F3F3293E@wh01ex01.ceskymobil.cz>; from Milon.Papezik@oskarmobil.cz on Fri, Jul 27, 2001 at 10:15:32AM %2B0200
References:  <B57AF59C8ABFD411BBE000508BF300F3F3293E@wh01ex01.ceskymobil.cz>

next in thread | previous in thread | raw e-mail | index | archive | help
On Fri, Jul 27, 2001 at 10:15:32AM +0200, Milon Papezik wrote:
> > -----Original Message-----
> > From: Bernd Walter [mailto:ticso@mail.cicely.de]
> > Sent: Thursday, July 26, 2001 19:12
> > To: Leo Bicknell
> > Cc: hackers@FreeBSD.ORG
> > Subject: Re: ARP cache problems....
> > 
> > 
> > On Thu, Jul 26, 2001 at 11:35:59AM -0400, Leo Bicknell wrote:
> > > On Thu, Jul 26, 2001 at 10:01:05AM +0200, Bernd Walter wrote:
> > > > But there is no reason to put more than one interface on 
> > the same hub.
> > > > Simply configure one interface with alias entries.
> > > 
> > > s/hub/switch/ and there is, and the system should make this not
> > > too painful to configure.  
> > 
> > If you are using a switch you should use FEC or VLANs.
> > Yes I know there switches out there without that features but if you
> > want more performance then use hardware that can do the job you need.
> 
> Could you please point me to some howto for FEC on FreeBSD ?

See the list archive - theres a Netgraph implementation for FreeBSD
available.

> I need to connect my server to two redundant switches
> (=> two connection, two cards, one logical interface, one ifconfig, ...).

FEC bundles ethernet channels between the same devices.
That doesn't help you in a multi switch case.
AFAIK you can't tell a switched network that a single MAC is connected
to more than one switch.  Switches are beleaving to see a loop and
disable one port.

-- 
B.Walter              COSMO-Project         http://www.cosmo-project.de