Skip site navigation (1)Skip section navigation (2)
Date:      Thu, 12 Nov 2009 18:46:42 +0100
From:      Miroslav Lachman <000.fbsd@quip.cz>
To:        David Christensen <davidch@broadcom.com>
Cc:        Tom Judge <tom@tomjudge.com>, "rwilliams@borderware.com" <rwilliams@borderware.com>, Gideon Naim <gideon.naim@broadcom.com>, "net@freebsd.org" <net@freebsd.org>
Subject:   Re: bce(4) BCM5907 CTX write errors on 7.2 driver
Message-ID:  <4AFC4A02.8080503@quip.cz>
In-Reply-To: <5D267A3F22FD854F8F48B3D2B52381933A20D4C55D@IRVEXCHCCR01.corp.ad.broadcom.com>
References:  <4AE72910.8090708@tomjudge.com>	<5D267A3F22FD854F8F48B3D2B52381933A04B49180@IRVEXCHCCR01.corp.ad.broadcom.com>	<4AE76FF1.9010401@tomjudge.com>	<5D267A3F22FD854F8F48B3D2B52381933A04B491AE@IRVEXCHCCR01.corp.ad.broadcom.com>	<4AE8CC59.7020004@tomjudge.com> <4AE9D10F.4040703@tomjudge.com>	<5D267A3F22FD854F8F48B3D2B52381933A054DE883@IRVEXCHCCR01.corp.ad.broadcom.com>	<4AE9F576.4060101@tomjudge.com>	<5D267A3F22FD854F8F48B3D2B52381933A19B35A55@IRVEXCHCCR01.corp.ad.broadcom.com>	<4AEA0B11.2050209@tomjudge.com>	<5D267A3F22FD854F8F48B3D2B52381933A19B35AB0@IRVEXCHCCR01.corp.ad.broadcom.com>	<4AEA1183.7050306@tomjudge.com> <4AEB2571.7090006@tomjudge.com>	<4AFAE428.5090907@quip.cz> <5D267A3F22FD854F8F48B3D2B52381933A20D4C55D@IRVEXCHCCR01.corp.ad.broadcom.com>

next in thread | previous in thread | raw e-mail | index | archive | help
David Christensen wrote:
> Hi,
>> we have two new Dell R610 machines with four bce NICs (only
>> bce0 is connected at this time). I tried cold (power cycle in
>> iDRAC) and warm reboot (shutdown -r now), NIC is working on
>> every reboot, but I am still seeing messages:
>>
>> bce0: /usr/src/sys/dev/bce/if_bce.c(1525): PHY write timeout!
>> bce0: /usr/src/sys/dev/bce/if_bce.c(1525): PHY write timeout!
>> bce0: link state changed to UP
>>
>> This is on FreeBSD 7.2-RELEASE-p4 amd64
>>
>> I also see "PHY write timeout" on shutdown time for each NIC.
>>
>> Other than the log messages, I see no problems with bce NIC,
>> but I have not tested it with any high load.
>>
>> I did not upgraded FW or anything else.
>>
>> What can I do to help with solving this issue?
>
> You'll need to upgrade to 7-STABLE.
>
> Dave

Thank you!

Todays 7-STABLE seems fine.
FreeBSD 7.2-STABLE #1: Thu Nov 12 17:20:36 CET 2009 GENERIC amd64

bce0 has firmware 5.0.9 and is attached to brgphy instead of previous ukphy.

bce0: <Broadcom NetXtreme II BCM5709 1000Base-T (C0)> mem 
0xd6000000-0xd7ffffff irq 36 at device 0.0 on pci1
miibus0: <MII bus> on bce0
brgphy0: <BCM5709C 10/100/1000baseTX PHY> PHY 1 on miibus0
brgphy0:  10baseT, 10baseT-FDX, 100baseTX, 100baseTX-FDX, 1000baseT, 
1000baseT-FDX, auto

No more "PHY write timeout" messages on shutdown or bootup.

So problem seems solved by 7-STABLE.

Miroslav Lachman



Want to link to this message? Use this URL: <https://mail-archive.FreeBSD.org/cgi/mid.cgi?4AFC4A02.8080503>