Skip site navigation (1)Skip section navigation (2)
Date:      Mon, 5 Feb 1996 14:52:10 +0200
From:      "Andrew V. Stesin" <stesin@elvisti.kiev.ua>
To:        hackers@freebsd.org
Subject:   Re: Problem with new drive (Connor CFP1060S 1.05GD 243F)
Message-ID:  <199602051252.OAA05742@office.elvisti.kiev.ua>

next in thread | raw e-mail | index | archive | help
Michael Smith wrote:

: Marc G. Fournier stands accused of saying:
: > 
: > When I tried to install, it newfs'd 3 partitions, then got the above error
: > on the 4th (you could hear the drive powerdown) and then when it went to 
: > the 5th, you could hear it power up again, and it newfs'd it and the 6th
: > properly again.

: Aiee!  Unless you have a faulty power connector, _send_it_back_ right now.
: If it's spinning down the drive is sure it has a _serious_ problem.

	I STRONGLY second this. We had this same drive model died recently.
	Two last days before final death it was stinking with the
	messages "not ready" to the console...

: > (aha0:0:0): "CONNER CFP1060S 1.05GB 243F" type 0 fixed SCSI 2
: > sd0(aha0:0:0): Direct-Access 1013MB (2074880 512 byte sectors)

: Some firmware revisions of this drive have problems with large read/write
: operations.  I'd suggest searching the list archives...

	That's not the issue. Faulty drives were _before_ 203C
	firmware revision, this one is 243F;
	and two older drives which were upgraded to 203C are still Ok
	here.

--

	With best regards -- Andrew Stesin.

	+380 (44) 2760188	+380 (44) 2713457	+380 (44) 2713560

	"You may delegate authority, but not responsibility."
					Frank's Management Rule #1.



Want to link to this message? Use this URL: <https://mail-archive.FreeBSD.org/cgi/mid.cgi?199602051252.OAA05742>