Date:      Sat, 9 Oct 2004 22:09:22 +0200
From:      "Daniel Eriksson" <daniel_k_eriksson@telia.com>
To:        "'Sean McNeil'" <sean@mcneil.com>, <freebsd-current@freebsd.org>
Subject:   RE: re0 failures at 1Gb vs. 100Mb
Message-ID:  <!~!UENERkVCMDkAAQACAAAAAAAAAAAAAAAAABgAAAAAAAAA0VcX9IoJqUaXPS8MjT1PdsKAAAAQAAAAUEuns37%2BsEiao5A6tA31BwEAAAAA@telia.com>
In-Reply-To: <1097346626.3446.50.camel@server>

next in thread | previous in thread | raw e-mail | index | archive | help
Sean McNeil wrote:

> I have a strange problem that I have with my network that is 
> related to the output rate of my re0.

I have a similar problem, but I haven't reported it before because I wasn't
sure it was the fault of the NIC.

No matter what I do, single connection output rate (TCP) from the RealTek is
erratic and the average is well below expectations when it operates at
1Gbit. If I force it to 100Mbit (either through ifconfig, or by placing a
cheap 100Mbit switch in between it and GigE switch) the average speed goes
up quite a bit due to a much more stable and consistently high single
connection throughput.

I have not done much testing of this, but I thought it would be useful to
know that others are having issues too.

/Daniel Eriksson