Skip site navigation (1)Skip section navigation (2)
Date:      Sun, 9 Sep 2001 02:39:41 +0000
From:      Michael Burns <michael@fasturl.net>
To:        Tom Samplonius <tom@sdf.com>
Cc:        freebsd-scsi@freebsd.org
Subject:   Re: RAID 5 controller replacement (DPT/Adaptec SmartRAID IV)
Message-ID:  <20010909023941.A89545@fasturl.net>
In-Reply-To: <Pine.BSF.4.05.10109081849500.229-100000@misery.sdf.com>; from tom@sdf.com on Sat, Sep 08, 2001 at 06:50:44PM -0700
References:  <20010909003733.A60723@fasturl.net> <Pine.BSF.4.05.10109081849500.229-100000@misery.sdf.com>

next in thread | previous in thread | raw e-mail | index | archive | help
ON Sat, Sep 08, 2001 at 06:50:44PM -0700, Tom Samplonius wrote: 
> 
> On Sun, 9 Sep 2001, Michael Burns wrote:
>
> > Do you know whether the array was RAID 5?
> 
>   Yes, it was RAID 5.  I don't really see that the DPT treats logical
> disks any differently no matter what the RAID level.  The config goes on
> disk regardless.

That's what I had hoped. Thanks for the response and the clarification.

-- 
Michael Burns
Systems Administrator
Vener Net Inc.