Date: Sun, 15 Jun 2008 20:47:38 +0400 From: Lev Serebryakov <lev@serebryakov.spb.ru> To: Erik Trulsson <ertr1013@student.uu.se> Cc: freebsd-hackers@freebsd.org Subject: Re[2]: UPS shutdown with `sysutils/nut': where should I place "power off" command to UPS? Message-ID: <31567013.20080615204738@serebryakov.spb.ru> In-Reply-To: <20080615162247.GA50613@owl.midgard.homeip.net> References: <1283529703.20080615190810@serebryakov.spb.ru> <20080615162247.GA50613@owl.midgard.homeip.net>
next in thread | previous in thread | raw e-mail | index | archive | help
Hello, Erik. You wrote 15 =E8=FE=ED=FF 2008 =E3., 20:22:47: > You need an UPS that can accept a signal that says 'shut down in 20 secon= ds > time' (the value 20 may have to be adjusted) and send that as the last th= ing > in the shutdown scripts, which should cause the UPS to shutdown shortly > after 'shutdown -p' has turned off the computer. It seems, that my Ippon Smart Power Pro/1000 understand such commands: it can turn off load after 2 minutes, and I'll try to change this value. Great. --=20 // Black Lion AKA Lev Serebryakov <lev@serebryakov.spb.ru>