Geoff Buckingham writes:
 > On Thu, Oct 14, 1999 at 04:55:45PM -0600, Kenneth D. Merry wrote:
 > > 
 > > Western Digital drives generally aren't that great.  In fact, we have
 > > disabled tagged queueing for most all Western Digital SCSI drives.
 > > (including the drives you have, above)
 > > 
 > 
 > I have been meaning to post on this subject for some time, while in my last 
 > place of employment I bought 8 Dell PowerEdge 2300s each with six drives
 > Dell supplied Western digitals and I had really poor disk performance.
 > 
 > I realised tagged queing was disabled for WDE* and removed the quirk from
 > cam_xpt.c this greatly improved the performance.  Much exercising of the disks
 > also failed to cause any further problems.

I'm the guy to blame for this quirk.  My drives (shipped in about 60
older Dell Dimension XPS D300 here) have abysmal sequential write
performance with tagged queuing enabled.  There are two types of
identifiers:

pass0: <WDIGTL WDE4360-1807A3 1.80> Fixed Direct Access SCSI-2 device 
pass0: Serial Number WS7010610507
pass0: 40.000MB/s transfers (20.000MHz, offset 8, 16bit)

pass1: <WDIGTL ENTERPRISE 1.91> Fixed Direct Access SCSI-2 device 
pass1: Serial Number WS7011244369
pass1: 40.000MB/s transfers (20.000MHz, offset 8, 16bit)

From the reports I've seen, it looks like Western Digital got their
act together and their Ultra2 drives are OK.  Could we make the quirk
entry enable tagged queuing for Ultra2 WDE drives & disable it for
non-ultra2 drives?

Also, would it be possible to enable/disable tagged queuing from
camcontrol?  Or to read the quirks from a config file (like Digital
UNIX does with its ddr.db file..).

Drew

------------------------------------------------------------------------------
Andrew Gallatin, Sr Systems Programmer	http://www.cs.duke.edu/~gallatin
Duke University				Email: gallatin@cs.duke.edu
Department of Computer Science		Phone: (919) 660-6590


To Unsubscribe: send mail to majordomo@FreeBSD.org
with "unsubscribe freebsd-scsi" in the body of the message




Want to link to this message? Use this URL: <https://mail-archive.FreeBSD.org/cgi/mid.cgi?14343.16009.738375.608477>