Skip site navigation (1)Skip section navigation (2)
Date:      Fri, 19 Aug 2011 16:50:01 -0400
From:      Dan Langille <dan@langille.org>
To:        freebsd-stable@freebsd.org
Subject:   bad sector in gmirror HDD
Message-ID:  <1B4FC0D8-60E6-49DA-BC52-688052C4DA51@langille.org>

next in thread | raw e-mail | index | archive | help
System in question: FreeBSD 8.2-STABLE #3: Thu Mar  3 04:52:04 GMT 2011

After a recent power failure, I'm seeing this in my logs:

Aug 19 20:36:34 bast smartd[1575]: Device: /dev/ad2, 2 Currently =
unreadable (pending) sectors

And gmirror reports:

# gmirror status
      Name    Status  Components
mirror/gm0  DEGRADED  ad0 (100%)
                      ad2

I think the solution is: gmirror rebuild

Comments?



Searching on that error message, I was led to believe that identifying =
the bad sector and
running dd to read it would cause the HDD to reallocate that bad block.

  http://smartmontools.sourceforge.net/badblockhowto.html

However, since ad2 is one half of a gmirror, I don't think this is the =
best approach.

Comments?




More information:

smartd, gpart, dh, diskinfo, and fdisk output at =
http://beta.freebsddiary.org/smart-fixing-bad-sector.php

also:

# gmirror list
Geom name: gm0
State: DEGRADED
Components: 2
Balance: round-robin
Slice: 4096
Flags: NONE
GenID: 0
SyncID: 1
ID: 3362720654
Providers:
1. Name: mirror/gm0
   Mediasize: 40027028992 (37G)
   Sectorsize: 512
   Mode: r6w5e14
Consumers:
1. Name: ad0
   Mediasize: 40027029504 (37G)
   Sectorsize: 512
   Mode: r1w1e1
   State: SYNCHRONIZING
   Priority: 0
   Flags: DIRTY, SYNCHRONIZING
   GenID: 0
   SyncID: 1
   Synchronized: 100%
   ID: 949692477
2. Name: ad2
   Mediasize: 40027029504 (37G)
   Sectorsize: 512
   Mode: r1w1e1
   State: ACTIVE
   Priority: 0
   Flags: DIRTY, BROKEN
   GenID: 0
   SyncID: 1
   ID: 3585934016



--=20
Dan Langille - http://langille.org