Skip site navigation (1)Skip section navigation (2)
Date:      Fri, 29 Apr 2005 10:45:05 -0700
From:      Matt Staroscik <matt@wrongcrowd.com>
To:        freebsd-questions@freebsd.org
Subject:   3ware rebuild problems fixed
Message-ID:  <427272A1.9080800@wrongcrowd.com>
In-Reply-To: <20050429120035.A9EF916A4D7@hub.freebsd.org>
References:  <20050429120035.A9EF916A4D7@hub.freebsd.org>

next in thread | previous in thread | raw e-mail | index | archive | help
I solved my own problem a while back and neglected to post my solution. 
I hate it when people do that to me. :)

My original post is here:

http://lists.freebsd.org/pipermail/freebsd-questions/2004-November/064038.html

The summary is simply this: when rebuilding a mirror on a 3ware 7000-2, 
the rebuild would crap out with a vague disk error message. Doing a dump 
on the volume uncovered a couple of read errors.

Solution:

The read errors were killing the rebuild process. The hard disk's 
built-in SMART error correction was not kicking in though, because it 
only corrects bad sectors on a write. I tried to fix the disk with fsck, 
but the damage was too low-level, I guess...

Anyway, I deleted the files with read errors--luckily they were 
trivial--and then copied a load of files to the partition to fill up the 
empty space. This triggered a SMART sector repair--I verified that with 
a SMART checker from ports.

Once the bad sectors were remapped, I was able to rebuild my array.

Hope this helps someone!

-- 
***** I am Matt Staroscik and I approved this message. ******
matt@wrongcrowd.com * http://wrongcrowd.com * 4 8 15 16 23 42