next in thread | previous in thread | raw e-mail | index | archive | help
I use upsmon from the ports. It comes with upsstat, a program that queries the
UPS itself and finds out battery voltages etc.


        UPSMON Status Reporting Facility
        ---  upsmond version 2.1.3  ---

             APC UPS 700 Status Info
--------------------------------------------------------
                     Model: SMART-UPS 700
                 CopyRight: (C) APCC
          Manufacture date: 12/18/99
                  Serial #: NS9951331687
          Firmware version: 50.11.I
                  Local ID: UPS_IDEN
 Last battery replace date: 12/18/99
      Nominal line voltage: 230 V
   Nominal battery voltage: 24 V
                 Available: YES
                   Standby: NO
                Line Power: OK
                   Battery: OK
              Line Voltage: 231.40
                      Load:  23.40 %
           Battery Voltage:  27.60
             Battery Level: 100.00 %
--------------------------------------------------------




/M
On 19-Jun-01 G D McKee wrote:
> Hi
> 
> I have a Smart UPS 1000 and the last time the battery lights started
> flashing the batteries were on there way out!!!  New batteries and some
> calibration sorted the problem for me.
> 
> Gordon
> 
> ----- Original Message -----
> From: "Mario Doria" <madd@tecdigital.net>
> To: "FreeBSD Questions" <freebsd-questions@FreeBSD.ORG>
> Sent: Sunday, June 17, 2001 3:55 AM
> Subject: UPS Monitor question
> 
> 
>> Hi,
>>
>> I was using upsd from the ports collection to monitor my ups (APC SmartUPS
>> 2400), but sometimes the battery status in the UPS starts blinking, and
> the
>> sensitivity register gets changed to low. I'm looking for a better
>> alternative, any suggestions?
>>
>>
>> Thanks,
>>
>>
>> Mario Doria
>>
>>
>> To Unsubscribe: send mail to majordomo@FreeBSD.org
>> with "unsubscribe freebsd-questions" in the body of the message
>>
> 
> 
> To Unsubscribe: send mail to majordomo@FreeBSD.org
> with "unsubscribe freebsd-questions" in the body of the message

----------------------------------
Michael Josefsson, MSEE